Comparison of radiography- and computed tomography-based treatment planning in cervix cancer in brachytherapy with specific attention to some quality assurance aspects.

INTRODUCTION A modern approach in treatment planning for cervix carcinoma is based on a series of computed tomography (CT) sections and 3D dose computation. When these techniques were not yet available, dose evaluation was based on orthogonal radiographs. The CT based planning provides information on target and organ volumes and dose-volume histograms. The radiography based planning provides only dimensions and doses at selected points. The aim of the presented study is to correlate the information obtained with the two approaches for high dose-rate (HDR) brachytherapy of cervix carcinoma. METHODS For the study 28 patients with 35 applications receiving HDR treatment with Ir-192 were investigated. The planning system PLATO (Nucletron) was used. The different aspects of available data, results and inaccuracies regarding quality assurance were looked at. RESULTS From the CT based planning, the volume, location and dose-volume histograms were calculated for the CTV, rectum and bladder. From the radiography-based planning, the dose to point A (prescription), point B, rectum and bladder ICRU reference points [14], points related to the bony structures could be evaluated as well as volumes receiving different dose levels. These two sets of information were compared and following mean values derived. For a dose prescription of 7 Gy at point A, as an average, 83% (44 cm(3)) of the clinical target volume (CTV) receives at least 7 Gy. The mean dose at the rectum ICRU reference point is 4.3 Gy, and 12% (9 cm(3)) of the rectum is encompassed by the 4.3 Gy isodose. The mean dose at the bladder ICRU reference point is 5.8 Gy, and 8% (16 cm(3)) of the bladder is encompassed by the 5.8 Gy isodose. The maximum dose to the rectum is 1.5 times higher than the dose at the ICRU reference point, and for the bladder 1.4 times higher. Uncertainties caused by the reconstruction of the applicator and merging of isodoses could be evaluated. DISCUSSION The subdivision of different approaches and the transfer from point doses to volumes in treatment planning is possible and practical for the treatment of cervix carcinoma in brachytherapy.

[1]  J. Horiot,et al.  A quantified approach to the analysis and prevention of urinary complications in radiotherapeutic treatment of cancer of the cervix. , 1987, International journal of radiation oncology, biology, physics.

[2]  S L Schoeppel,et al.  Three-dimensional treatment planning of intracavitary gynecologic implants: analysis of ten cases and implications for dose specification. , 1994, International journal of radiation oncology, biology, physics.

[3]  I. Rosen,et al.  Uncertainty in dose estimation for gynecological implants. , 1990, International journal of radiation oncology, biology, physics.

[4]  J. Fowler,et al.  High dose rate intracavitary brachytherapy for carcinoma of the cervix: the Madison system: II. Procedural and physical considerations. , 1992, International journal of radiation oncology, biology, physics.

[5]  G. Stuecklschweiger,et al.  Bladder and rectal dose of gynecologic high-dose-rate implants: comparison of orthogonal radiographic measurements with in vivo and CT-assisted measurements. , 1991, Radiology.

[6]  I K Kolkman-Deurloo,et al.  Reconstruction accuracy of a dedicated localiser for filmless planning in intra-operative brachytherapy. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  G. Rauthe,et al.  High dose rate afterloading in the treatment of cancer of the uterus, breast and rectum , 1988 .

[8]  C. Moore,et al.  Bladder base dosage in patients undergoing intracavitary therapy. , 1986, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  J. M. Wilkinson,et al.  The ICRU recommendations for reporting intracavitary therapy in gynaecology and the Manchester method of treating cancer of the cervix uteri. , 1989, British Journal of Radiology.

[10]  A. Gerbaulet,et al.  Combined radiotherapy and surgery: local control and complications in early carcinoma of the uterine cervix--the Villejuif experience, 1975-1984. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  P. Grigsby,et al.  Estimation of tissue volume irradiated by intracavitary implants. , 1993, International journal of radiation oncology, biology, physics.

[12]  H Meertens A comparison of dose calculations at points around an intracavitary cervix applicator. , 1989, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  A. Visser,et al.  Technical aspects of bladder dosimetry in intracavitary irradiation of cervix carcinoma. , 1986, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  A Niroomand-Rad,et al.  Evaluation of the reconstruction of brachytherapy implants in three-dimensions from stereo radiographs. , 1987, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  B. Jones,et al.  Bladder dose estimation during intracavitary brachytherapy for carcinoma of the cervix using a single line source system. , 1996, The British journal of radiology.

[16]  J. Mizoe Analysis of the dose-volume histogram in uterine cervical cancer by diagnostic CT. , 1990, Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al].

[17]  G. Stuecklschweiger,et al.  Dosimetry of intracavitary placements for uterine and cervical carcinoma: results of orthogonal film, TLD, and CT-assisted techniques. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[18]  I. Barillot,et al.  Maximum and mean bladder dose defined from ultrasonography. Comparison with the ICRU reference in gynaecological brachytherapy. , 1994, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  P. S. Viswanathan,et al.  Treatment volume from total reference air kerma (TRAK) in intracavitory applications and its comparison with ICRU reference volume. , 1994, International journal of radiation oncology, biology, physics.

[20]  P. Almond,et al.  Quality assurance in brachytherapy: the role of the ICRU in achieving uniformity in dose and volume specification for reporting. , 1996, Rays.

[21]  A. Olch,et al.  Application of the ICRU Report 38 reference volume concept to the radiotherapeutic management of recurrent endometrial and cervical carcinoma. , 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[22]  R. Pötter,et al.  Definitive radiotherapy based on HDR brachytherapy with iridium 192 in uterine cervix carcinoma: report on the Vienna University Hospital findings (1993-1997) compared to the preceding period in the context of ICRU 38 recommendations. , 2000, Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique.

[23]  J. Horiot,et al.  Reference volume, milligram-hours and external irradiation for the Fletcher applicator. , 1987, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[24]  J. Horiot,et al.  Dosimetric methods in the optimization of radiotherapy for carcinoma of the uterine cervix. , 1987, International journal of radiation oncology, biology, physics.

[25]  R van der Laarse,et al.  Technique and individual afterloading treatment planning simulating classic Stockholm brachytherapy for cervix cancer. , 1988, Sonderbande zur Strahlentherapie und Onkologie.

[26]  P. Grigsby,et al.  Anatomic variation of gynecologic brachytherapy prescription points. , 1993, International journal of radiation oncology, biology, physics.

[27]  S. Smalley,et al.  Dosimetric analysis in brachytherapy of carcinoma of the cervix. , 1990, International journal of radiation oncology, biology, physics.

[28]  P. S. Viswanathan,et al.  Dosimetry of intracavitary applications in carcinoma of the cervix: rectal dose analysis. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[29]  J. Horiot,et al.  Dose-volume analysis and the prevention of radiation sequelae in cervical cancer. , 1987, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[30]  Icru Prescribing, recording, and reporting photon beam therapy , 1993 .