Developments in optical coherence microscopy

Optical Coherence Microscopy (OCM) utilizes a high NA microscope objective in the sample arm to achieve an axially and laterally high resolution OCT image. An increase in NA, however, leads to a dramatically decreased depth of focus (DOF), and hence shortens the imaging depth range so that high lateral resolution is maintained only within a small depth region around the focal plane. One solution to increase the depth of imaging while keeping a high lateral resolution is dynamic-focusing. Utilizing the voltage controlled refocus capability of a liquid lens, we have recently presented a solution for invariant high resolution imaging using the liquid lens embedded within a fixed optics hand-held custom microscope designed specifically for optical imaging systems using a broadband light source centered at 800 nm with a 120 nm bandwidth. Subsequently, we have developed a Gabor-Domain Optical Coherence Microscopy (GD-OCM) that utilizes the high speed imaging of spectral domain OCT, the high lateral resolution of OCM, and the ability of real time refocusing of our custom design variable focus objective. Finally, key developments in Phase-Resolved Doppler OCT (PR-DOCT) are key enablers to combine high-resolution structural imaging with functional imaging. In this paper we review achievements in GD-OCM and detail how portions of in-focus cross-sectional images can be extracted and fused to form an invariant lateral resolution image with multiple cross-sectional images acquired corresponding to a discrete refocusing step along depth enabled by the varifocal device. We demonstrate sub-cellular resolution imaging of an African frog tadpole (Xenopus Laevis) taken from a 500 μm × 500 μm cross-section as well as cellular imaging in in vivo skin. Finally, A novel dual-detection full-range Fourier-domain optical coherence tomography system was developed that provides 7 μm axial resolution (in air) at about 90 kHz axial scan rate for mirror-image phase resolved Doppler imaging in an African frog tadpole and an in vivo human finger.

[1]  F. S. Foster,et al.  Ultrasound backscatter microscopy images the internal structure of living tumour spheroids , 1987, Nature.

[2]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[3]  J. Fujimoto,et al.  Optical coherence microscopy in scattering media. , 1994, Optics letters.

[4]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[5]  Joseph M. Schmitt,et al.  An optical coherence microscope with enhanced resolving power , 1997 .

[6]  J. Fujimoto,et al.  In vivo ultrahigh-resolution optical coherence tomography. , 1999, Optics letters.

[7]  A. Fercher,et al.  Dynamic coherent focus OCT with depth-independent transversal resolution , 1999 .

[8]  David A. Jackson,et al.  Three dimensional OCT images from retina and skin. , 2000, Optics express.

[9]  B. Bouma,et al.  Handbook of Optical Coherence Tomography , 2001 .

[10]  J. Fujimoto,et al.  Ultrahigh-resolution optical coherence tomography using continuum generation in an air-silica microstructure optical fiber. , 2001, Optics letters.

[11]  Zhihua Ding,et al.  High-resolution optical coherence tomography over a large depth range with an axicon lens. , 2002, Optics letters.

[12]  B. Bouma,et al.  Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. , 2003, Optics letters.

[13]  I. Alex Vitkin,et al.  Dynamic focus control in high-speed optical coherence tomography based on a microelectromechanical mirror , 2004 .

[14]  James G Fujimoto,et al.  Three-dimensional and C-mode OCT imaging with a compact, frequency swept laser source at 1300 nm. , 2005, Optics express.

[15]  Xingde Li,et al.  Continuous focus tracking for real-time optical coherence tomography. , 2005, Optics letters.

[16]  Jun Zhang,et al.  Dynamically focused optical coherence tomography for endoscopic applications , 2005 .

[17]  Eric Clarkson,et al.  Dispersion control with a Fourier-domain optical delay line in a fiber-optic imaging interferometer. , 2005, Applied optics.

[18]  Zhongping Chen,et al.  GRIN lens rod based probe for endoscopic spectral domain optical coherence tomography with fast dynamic focus tracking. , 2006, Optics express.

[19]  J P Rolland,et al.  Invariant resolution dynamic focus OCM based on liquid crystal lens. , 2007, Optics express.

[20]  Jannick P Rolland,et al.  Bessel beam spectral-domain high-resolution optical coherence tomography with micro-optic axicon providing extended focusing range. , 2008, Optics letters.

[21]  J. Fujimoto,et al.  Ultrahigh speed spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second. , 2008, Optics express.

[22]  Supraja Murali,et al.  Three-dimensional adaptive microscopy using embedded liquid lens. , 2009, Optics letters.

[23]  Kye-Sung Lee,et al.  Quantification of resolution for a dynamic focusing OCM microscope , 2009, BiOS.

[24]  Panomsak Meemon,et al.  Gabor-based fusion technique for Optical Coherence Microscopy. , 2010, Optics express.

[25]  Kye-Sung Lee,et al.  Full-range spectral domain Doppler optical coherence tomography , 2010, BiOS.

[26]  J. Rolland,et al.  High Resolution Ocular Surface OCT to Directly Measure Tear Film Thickness in Human Eyes , 2010 .

[27]  Kye-Sung Lee,et al.  Sub-cellular resolution imaging with Gabor domain optical coherence microscopy , 2010, BiOS.

[28]  Kevin Hsu,et al.  Dual detection full range frequency domain optical coherence tomography. , 2010, Optics letters.

[29]  Panomsak Meemon,et al.  Assessment of a liquid lens enabled in vivo optical coherence microscope. , 2010, Applied optics.

[30]  P. Meemon,et al.  Gabor domain optical coherence microscopy , 2008, BiOS.

[31]  Kye-Sung Lee,et al.  High resolution axicon-based endoscopic FD OCT imaging with a large depth range , 2010, BiOS.

[32]  Jannick P. Rolland,et al.  Swept-source based, single-shot, multi-detectable velocity range Doppler optical coherence tomography , 2010, Biomedical optics express.

[33]  Kye-Sung Lee,et al.  Two-photon microscopy with dynamic focusing objective using a liquid lens , 2010, BiOS.

[34]  Jannick P. Rolland,et al.  Doppler imaging with dual-detection full-range frequency domain optical coherence tomography , 2010, Biomedical optics express.