THD mitigation in type-4 Wind Turbine through AFE Back to back converter

In wind power generation systems the type-4 Wind Turbine (WT) is the best option for future research, since WT is completely isolated from AC network through Back to back converter. Hence, full scale back to back is required for high power operation. Total Harmonic Distortion (THD) generated on AC grid by WT is depending of back to back converter switching frequency. In this paper, an AFE back to back converter to transfer high power when m VSCs are placed in parallel is developed, with significant THD reduction through SPWM techniques.

[1]  P. Marino,et al.  Evaluation of current harmonic distortion in wind farm application based on Synchronous Active Front End converters , 2011, IEEE Africon '11.

[2]  Ian A. Hiskens Dynamics of type-3 wind turbine generator models , 2012, PES 2012.

[3]  Viboon Chunkag,et al.  Parallelling three-phase AC to DC converter using CUK rectifier modules based on power balance control technique , 2010 .

[4]  P. Ladoux,et al.  Considerations on boost inductor design in back-to-back converters for renewable energy , 2011, 2011 International Conference on Clean Electrical Power (ICCEP).

[5]  Ye Zhang,et al.  Improved Selective Harmonics Elimination Scheme With Online Harmonic Compensation for High-Power PWM Converters , 2015, IEEE Transactions on Power Electronics.

[6]  Nady Rocha,et al.  Single-Phase to Three-Phase Drive System Using Two Parallel Single-Phase Rectifiers , 2010, IEEE Transactions on Power Electronics.

[7]  Frede Blaabjerg,et al.  Open-Switch Fault Detection Method of a Back-to-Back Converter Using NPC Topology for Wind Turbine Systems , 2015, IEEE Transactions on Industry Applications.

[8]  Oriol Gomis-Bellmunt,et al.  Control of a wind turbine cluster based on squirrel cage induction generators connected to a single VSC power converter , 2014 .

[9]  José R. Espinoza,et al.  Digital Implementation of Selective Harmonic Elimination Techniques in Modular Current Source Rectifiers , 2013, IEEE Transactions on Industrial Informatics.

[10]  Gerry Moschopoulos,et al.  A Novel Single-Stage Multilevel Type Full-Bridge Converter , 2013, IEEE Transactions on Industrial Electronics.

[11]  Mehrdad Ehsani,et al.  Improved selective harmonic elimination pulse-width modulation strategy in multilevel inverters , 2012 .

[12]  José M. Espí,et al.  Wind Turbine Generation System With Optimized DC-Link Design and Control , 2013, IEEE Transactions on Industrial Electronics.

[13]  Imed Jlassi,et al.  Multiple Open-Circuit Faults Diagnosis in Back-to-Back Converters of PMSG Drives for Wind Turbine Systems , 2015, IEEE Transactions on Power Electronics.

[14]  Chung-Chuan Hou A Multicarrier PWM for Parallel Three-Phase Active Front-End Converters , 2013, IEEE Transactions on Power Electronics.

[15]  V. Agelidis,et al.  Selective harmonic elimination pulse-width modulation seven-level cascaded H-bridge converter with optimised DC voltage levels , 2012 .

[16]  Olimpo Anaya-Lara,et al.  Fault Ride-Through Improvement of DFIG-WT by Integrating a Two-Degrees-of-Freedom Internal Model Control , 2013, IEEE Transactions on Industrial Electronics.

[17]  Antonio T. Alexandridis,et al.  Full-Scale Modeling, Control, and Analysis of Grid-Connected Wind Turbine Induction Generators With Back-to-Back AC/DC/AC Converters , 2014, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[18]  Georgios Konstantinou,et al.  Selective harmonic elimination pulse-width modulation of modular multilevel converters , 2013 .

[19]  Ye Zhang,et al.  Selective Harmonic Compensation (SHC) PWM for Grid-Interfacing High-Power Converters , 2014 .

[20]  J. Jatskevich,et al.  Dynamic Average-Value Modeling of Direct Power-Controlled Active Front-End Rectifiers , 2014, IEEE Transactions on Power Delivery.