Digital radiology using active matrix readout of amorphous selenium: geometrical and effective fill factors.

Flat panel self-scanned x-ray detectors using amorphous selenium (a-Se) as the photoconductor are being developed to replace both film/screen cassette systems for radiography and image intensifier (XRII)/video systems for fluoroscopy. These use a two-dimensional array of pixel electrodes to collect and readout the latent image charges formed on the photoconductor surface. The percentage of the area covered by the pixel electrodes (i.e., the geometrical fill factor fg) is always less than unity. In this paper, a novel approach is introduced to make the charge collection by pixel electrodes almost complete (i.e., a close to unity effective fill factor). The idea is to bend the electric field lines in the a-Se layer in such a way that image charges cannot land in the gap region between electrodes. This is achieved by depositing holes in the gap region, which is possible because there are charge traps available at the a-Se/insulator interface. The distribution of holes required in the gap region is calculated. Various factors associated with the feasibility of this approach as well as a method to deposit these holes are discussed. Application of the approach to the case of mammography is also included.

[1]  Denny L. Y. Lee,et al.  New digital detector for projection radiography , 1995, Medical Imaging.

[2]  J A Rowlands Digital X-ray systems based on amorphous selenium. , 1996, AJR. American journal of roentgenology.

[3]  Larry E. Antonuk,et al.  Development of thin-film flat-panel arrays for diagnostic and radiotherapy imaging , 1992, Medical Imaging.

[4]  J. Rowlands,et al.  Feasibility of a large area x-ray sensitive vidicon for medical fluoroscopy: signal and noise factors. , 1997, Medical physics.

[5]  J A Rowlands,et al.  X-ray imaging using amorphous selenium: photoinduced discharge (PID) readout for digital general radiography. , 1995, Medical physics.

[6]  John A. Rowlands,et al.  Large-area solid state detector for radiology using amorphous selenium , 1992, Medical Imaging.

[7]  Ian A. Cunningham Degradation of the detective quantum efficiency due to a nonunity detector fill factor , 1997, Medical Imaging.

[8]  K. Taketoshi,et al.  Avalanche-mode Amorphous Selenium Photoconductive Target for Camera Tube , 1988 .

[9]  I. Blevis,et al.  Digital radiology using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector. , 1997, Medical physics.

[10]  J A Rowlands,et al.  Digital radiology using active matrix readout of amorphous selenium: detectors with high voltage protection. , 1998, Medical physics.

[11]  J A Rowlands,et al.  Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency. , 1997, Medical physics.

[12]  J. W. Boag,et al.  REVIEW ARTICLE: Xeroradiography , 1973 .

[13]  J. Rowlands,et al.  Feasibility of a large area x-ray sensitive vidicon for medical fluoroscopy: resolution and lag factors. , 1997, Medical physics.

[14]  Norbert Conrads,et al.  Fluoroscopic x-ray imaging with amorphous silicon thin-film arrays , 1994, Medical Imaging.

[15]  J A Rowlands,et al.  X-ray imaging using amorphous selenium: inherent spatial resolution. , 1995, Medical physics.

[16]  Wei Zhao,et al.  Characteristics of dual-gate thin-film transistors for applications in digital radiology , 1996 .

[17]  Denny L. Y. Lee,et al.  Discussion on resolution and dynamic range of Se-TFT direct digital radiographic detector , 1996, Medical Imaging.