Robotic middle ear access for cochlear implantation: First in man

To demonstrate the feasibility of robotic middle ear access in a clinical setting, nine adult patients with severe-to-profound hearing loss indicated for cochlear implantation were included in this clinical trial. A keyhole access tunnel to the tympanic cavity and targeting the round window was planned based on preoperatively acquired computed tomography image data and robotically drilled to the level of the facial recess. Intraoperative imaging was performed to confirm sufficient distance of the drilling trajectory to relevant anatomy. Robotic drilling continued toward the round window. The cochlear access was manually created by the surgeon. Electrode arrays were inserted through the keyhole tunnel under microscopic supervision via a tympanomeatal flap. All patients were successfully implanted with a cochlear implant. In 9 of 9 patients the robotic drilling was planned and performed to the level of the facial recess. In 3 patients, the procedure was reverted to a conventional approach for safety reasons. No change in facial nerve function compared to baseline measurements was observed. Robotic keyhole access for cochlear implantation is feasible. Further improvements to workflow complexity, duration of surgery, and usability including safety assessments are required to enable wider adoption of the procedure.

[1]  Peter Kazanzides,et al.  Medical robotics—Regulatory, ethical, and legal considerations for increasing levels of autonomy , 2017, Science Robotics.

[2]  Marco Caversaccio,et al.  The accuracy of image-based safety analysis for robotic cochlear implantation , 2018, International Journal of Computer Assisted Radiology and Surgery.

[3]  Matthew G. Crowson,et al.  Quality of Life and Cost-Effectiveness of Cochlear Implants: A Narrative Review , 2017, Audiology and Neurotology.

[4]  A. Rivas,et al.  Towards a consensus on a hearing preservation classification system , 2013, Acta oto-laryngologica. Supplementum.

[5]  R. V. Hoesel Bilateral Cochlear Implants , 2011 .

[6]  P. Marik,et al.  Narrative Review , 2012, Journal of intensive care medicine.

[7]  Marco Caversaccio,et al.  Surgical planning tool for robotically assisted hearing aid implantation , 2013, International Journal of Computer Assisted Radiology and Surgery.

[8]  J. Nedzelski,et al.  Development of a sensitive clinical facial grading system. , 1996, European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery.

[9]  N Marangos,et al.  COCHLEAR IMPLANTS , 1976, The Lancet.

[10]  Marco Caversaccio,et al.  Cone Beam and Micro-Computed Tomography Validation of Manual Array Insertion for Minimally Invasive Cochlear Implantation , 2013, Audiology and Neurotology.

[11]  J. Allum,et al.  Cochlear implantation in children and adults in Switzerland. , 2014, Swiss medical weekly.

[12]  Marco Caversaccio,et al.  Population Statistics Approach for Safety Assessment in Robotic Cochlear Implantation. , 2017, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[13]  Marco Caversaccio,et al.  High-Accuracy Patient-to-Image Registration for the Facilitation of Image-Guided Robotic Microsurgery on the Head , 2013, IEEE Transactions on Biomedical Engineering.

[14]  Ramya Balachandran,et al.  Minimally invasive image‐guided cochlear implantation surgery: First report of clinical implementation , 2014, The Laryngoscope.

[15]  Marco Caversaccio,et al.  Semiautomatic Cochleostomy Target and Insertion Trajectory Planning for Minimally Invasive Cochlear Implantation , 2014, BioMed research international.

[16]  J. Kronenberg,et al.  Suprameatal Approach for Cochlear Implantation in Children: Our Experience with 320 Cases , 2010, Cochlear implants international.

[17]  Marco Caversaccio,et al.  In Vitro Accuracy Evaluation of Image-Guided Robot System for Direct Cochlear Access , 2013, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[18]  Marco Caversaccio,et al.  Instrument flight to the inner ear , 2017, Science Robotics.

[19]  S. Waltzman,et al.  Long‐term outcomes of cochlear implantation in patients with high‐frequency hearing loss , 2018, The Laryngoscope.

[20]  Marco Caversaccio,et al.  Neuromonitoring During Robotic Cochlear Implantation: Initial Clinical Experience , 2018, Annals of Biomedical Engineering.

[21]  R Häusler,et al.  Cochlear Implantation Without Mastoidectomy: The Pericanal Electrode Insertion Technique , 2002, Acta oto-laryngologica.

[22]  Marco Caversaccio,et al.  Cochlear Implant Insertion Depth Prediction: A Temporal Bone Accuracy Study. , 2018, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[23]  Thomas Klenzner,et al.  Minimally invasive, multi-port approach to the lateral skull base: a first in vitro evaluation , 2017, International Journal of Computer Assisted Radiology and Surgery.

[24]  Marco Caversaccio,et al.  Estimation of Tool Pose Based on Force–Density Correlation During Robotic Drilling , 2013, IEEE Transactions on Biomedical Engineering.

[25]  E. Genovese,et al.  Endoscopic cochlear implant procedure , 2014, European Archives of Oto-Rhino-Laryngology.

[26]  Marco Caversaccio,et al.  Robotic cochlear implantation: surgical procedure and first clinical experience , 2017, Acta oto-laryngologica.

[27]  Cilgia Dür,et al.  A Neuromonitoring Approach to Facial Nerve Preservation During Image-guided Robotic Cochlear Implantation , 2016, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology.

[28]  Robert G. Moore,et al.  Initial clinical experience , 1997 .

[29]  Juan Anso,et al.  Temperature Prediction Model for Bone Drilling Based on Density Distribution and In Vivo Experiments for Minimally Invasive Robotic Cochlear Implantation , 2016, Annals of Biomedical Engineering.