Computational fluid-dynamics optimization of a human tracheal endoprosthesis

Abstract The Dumon silicone stent is widely used in human medicine for treating tracheal diseases. Although presenting many advantages, as its facility of positioning and removing and its relative low cost, commonly reported complications include stent migration, inflammatory granulation tissue formation, and obstruction. Taking into account this last aspect, in this work we propose an improved stent design which may help in preventing episodes of mucous accumulation. In particular, we changed the design of the stent extremities in order to improve the flow field which cyclically crosses the prosthesis. To evaluate the performances of this new design, a finite element model of a human stented trachea was developed using a fluid–structure interaction approach (FSI). The geometry of the trachea is obtained from computed tomography (CT) images of a healthy patient. The simulations were performed using a finite element-based commercial software code. The tracheal wall is modeled as a fiber reinforced hyperelastic solid material in which we introduced the anisotropy due to the orientation of the fibers. Different new prosthesis designs were tested. Results showed that linear and parabolic transitions of the top and bottom stent extremities reduce the local vorticity field preventing high local flow recirculations during breathing.

[1]  M. Malvè,et al.  FSI Analysis of the Coughing Mechanism in a Human Trachea , 2010, Annals of Biomedical Engineering.

[2]  M. Malvè,et al.  Modeling of the fluid structure interaction of a human trachea under different ventilation conditions , 2011 .

[3]  T Gemci,et al.  Computational model of airflow in upper 17 generations of human respiratory tract. , 2008, Journal of biomechanics.

[4]  Gerard A. Silvestri,et al.  Silicone Stents versus Metal Stents for Management of Benign Tracheobronchial Disease Pro: Metal Stents , 2000 .

[5]  M. Doblaré,et al.  Patient-specific models of human trachea to predict mechanical consequences of endoprosthesis implantation , 2010, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[6]  Ananth V. Annapragada,et al.  Computational Fluid Dynamics Simulation of Airflow and Aerosol Deposition in Human Lungs , 2004, Annals of Biomedical Engineering.

[7]  Shanhong Ji,et al.  Finite element analysis of fluid flows fully coupled with structural interactions , 1999 .

[8]  M Doblaré,et al.  FSI Analysis of a healthy and a stenotic human trachea under impedance-based boundary conditions. , 2011, Journal of biomechanical engineering.

[9]  Kenneth R. Lutchen,et al.  An Anatomically Based Hybrid Computational Model of the Human Lung and its Application to Low Frequency Oscillatory Mechanics , 2006, Annals of Biomedical Engineering.

[10]  H. Y. Luo,et al.  Modeling the bifurcating flow in a CT-scanned human lung airway. , 2008, Journal of biomechanics.

[11]  Y Liu,et al.  Modeling the bifurcating flow in an asymmetric human lung airway. , 2003, Journal of biomechanics.

[12]  M. Noppen Airway injury and sequelae: conservative view , 2004 .

[13]  G B Fiore,et al.  A numerical and experimental study of compliance and collapsibility of preterm lamb tracheae. , 2004, Journal of biomechanics.

[14]  Arne Erik Holdø,et al.  Numerical simulation of respiratory flow patterns within human lung , 2002, Respiratory Physiology & Neurobiology.

[15]  Yuanle Ma,et al.  Solution Procedure for Transport Modeling in Effluent Recharge Based on Operator-Splitting Techniques , 2008 .

[16]  G. Yu,et al.  Computer Simulation of the Flow Field and Particle Deposition by Diffusion in a 3-D Human Airway Bifurcation , 1996 .

[17]  Y Liu,et al.  Modeling the bifurcating flow in a human lung airway. , 2002, Journal of biomechanics.

[18]  M Doblaré,et al.  CFD analysis of the human airways under impedance-based boundary conditions: application to healthy, diseased and stented trachea , 2013, Computer methods in biomechanics and biomedical engineering.

[19]  Timon Rabczuk,et al.  Fluid–structure interaction in lower airways of CT‐based lung geometries , 2008 .

[20]  J. Wain,et al.  Postintubation tracheal stenosis ☆ ☆☆ ★ ★★ ♢: Treatment and results , 1995 .

[21]  Nigel P. Weatherill,et al.  Steady flow through a realistic human upper airway geometry , 2008 .

[22]  J. Dumon,et al.  A dedicated tracheobronchial stent. , 1990, Chest.

[23]  M Doblaré,et al.  Experimental characterization and constitutive modeling of the mechanical behavior of the human trachea. , 2010, Medical engineering & physics.

[24]  R BELSEY,et al.  Resection and reconstruction of the intrathoracic trachea , 1950, The British journal of surgery.

[25]  M. Malvè,et al.  Numerical modeling of a human stented trachea under different stent designs , 2011 .

[26]  K. Bathe,et al.  Finite element developments for general fluid flows with structural interactions , 2004 .

[27]  Clement Kleinstreuer,et al.  Transient airflow structures and particle transport in a sequentially branching lung airway model , 2002 .

[28]  J. Halleux,et al.  An arbitrary lagrangian-eulerian finite element method for transient dynamic fluid-structure interactions , 1982 .

[29]  J L Bert,et al.  Ultrastructure and tensile properties of human tracheal cartilage. , 1997, Journal of biomechanics.

[30]  Ramana M. Pidaparti,et al.  Inhalation induced stresses and flow characteristics in human airways through fluid-structure interaction analysis , 2008 .

[31]  Manuel Maynar,et al.  Endotracheal stenting therapy in dogs with tracheal collapse. , 2008, Veterinary journal.

[32]  M Doblaré,et al.  FSI analysis of a human trachea before and after prosthesis implantation. , 2011, Journal of biomechanical engineering.

[33]  R. Ogden,et al.  A New Constitutive Framework for Arterial Wall Mechanics and a Comparative Study of Material Models , 2000 .

[34]  Chris Lacor,et al.  Fluid flow and particle deposition analysis in a realistic extrathoracic airway model using unstructured grids , 2007 .