Permanent Leadless Cardiac Pacing: Results of the LEADLESS Trial

Background— Conventional cardiac pacemakers are associated with several potential short- and long-term complications related to either the transvenous lead or subcutaneous pulse generator. We tested the safety and clinical performance of a novel, completely self-contained leadless cardiac pacemaker. Methods and Results— The primary safety end point was freedom from complications at 90 days. Secondary performance end points included implant success rate, implant time, and measures of device performance (pacing/sensing thresholds and rate-responsive performance). The mean age of the patient cohort (n=33) was 77±8 years, and 67% of the patients were male (n=22/33). The most common indication for cardiac pacing was permanent atrial fibrillation with atrioventricular block (n=22, 67%). The implant success rate was 97% (n=32). Five patients (15%) required the use of >1 leadless cardiac pacemaker during the procedure. One patient developed right ventricular perforation and cardiac tamponade during the implant procedure, and eventually died as the result of a stroke. The overall complication-free rate was 94% (31/33). After 3 months of follow-up, the measures of pacing performance (sensing, impedance, and pacing threshold) either improved or were stable within the accepted range. Conclusions— In a prospective nonrandomized study, a completely self-contained, single-chamber leadless cardiac pacemaker has shown to be safe and feasible. The absence of a transvenous lead and subcutaneous pulse generator could represent a paradigm shift in cardiac pacing. Clinical Trial Registration— URL: http://clinicaltrials.gov. Unique identifier: NCT01700244.

[1]  R. Erbel,et al.  Leadless Pacing of the Heart Using Induction Technology: A Feasibility Study , 2009, Pacing and clinical electrophysiology : PACE.

[2]  Kathy Lai-Fun Lee,et al.  In the wireless era: leadless pacing , 2010, Expert review of cardiovascular therapy.

[3]  Angelo Auricchio,et al.  First-in-man implantation of leadless ultrasound-based cardiac stimulation pacing system: novel endocardial left ventricular resynchronization therapy in heart failure patients. , 2013, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[4]  Gregory F Michaud,et al.  Incidence and predictors of major complications from contemporary catheter ablation to treat cardiac arrhythmias. , 2011, Heart rhythm.

[5]  H. Mond,et al.  The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's Project , 2011, Pacing and clinical electrophysiology : PACE.

[6]  J. W. Spickler,et al.  Totally self-contained intracardiac pacemaker. , 1970, Journal of electrocardiology.

[7]  Y Harada,et al.  A temperature-sensitive cardiac pacemaker. , 1983, Journal of medical engineering & technology.

[8]  J. Alpert,et al.  Recommendations from the Heart Rhythm Society Task Force on Lead Performance Policies and Guidelines: developed in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA). , 2009, Heart rhythm.

[9]  Karel G M Moons,et al.  Incidence and predictors of short- and long-term complications in pacemaker therapy: the FOLLOWPACE study. , 2012, Heart rhythm.

[10]  A. Manolis,et al.  Multi‐Center Clinical Experience with a Lumenless, Catheter‐Delivered, Bipolar, Permanent Pacemaker Lead: Implant Safety and Electrical Performance , 2006, Pacing and clinical electrophysiology : PACE.

[11]  K. Chan,et al.  Prevalence and mechanism of tricuspid regurgitation following implantation of endocardial leads for pacemaker or cardioverter-defibrillator. , 2012, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[12]  Hung-Fat Tse,et al.  First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices. , 2007, Journal of the American College of Cardiology.

[13]  Atul Verma,et al.  Pacemaker or defibrillator surgery without interruption of anticoagulation. , 2013, The New England journal of medicine.

[14]  Z. Emkanjoo,et al.  Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade. , 2007, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[15]  A. Russo,et al.  HRS/ACCF expert consensus statement on pacemaker device and mode selection. , 2012, Journal of the American College of Cardiology.

[16]  E. Nøhr,et al.  Risk factors for lead complications in cardiac pacing: a population-based cohort study of 28,860 Danish patients. , 2011, Heart rhythm.

[17]  David L Hayes,et al.  Clinical experience with pacemaker pulse generators and transvenous leads: an 8-year prospective multicenter study. , 2007, Heart rhythm.

[18]  D. Benditt,et al.  The leadless ultrasonic pacemaker: a sound idea? , 2009, Heart rhythm.

[19]  E. Alt,et al.  Rate control of physiologic pacemakers by central venous blood temperature. , 1986, Circulation.

[20]  Nora Toma,et al.  An entirely subcutaneous implantable cardioverter-defibrillator. , 2010, Maedica.

[21]  L. Jordaens,et al.  Evaluation of six minute walking test in patients with single chamber rate responsive pacemakers. , 1994, British heart journal.

[22]  A. Oto,et al.  Diagnosis and Management of Inadvertently Placed Pacing and ICD Leads in the Left Ventricle: A Multicenter Experience and Review of the Literature , 2000, Pacing and clinical electrophysiology : PACE.

[23]  C. Tsagarakis,et al.  A Miniature Pacemaker Introduced Intravenously and Implanted Endocardially. Preliminary Findings from an Experimental Study , 1991 .

[24]  T Sugano,et al.  [Heart rhythm]. , 2020, Nihon seirigaku zasshi. Journal of the Physiological Society of Japan.

[25]  H. Frumin,et al.  Acute complications of permanent pacemaker implantation: their financial implication and relation to volume and operator experience. , 2000, The American journal of cardiology.