An Efficient Micro-Stimulator Array Using Unitary-Size DAC With Adiabatic Baseband Scheme

This paper presents novel approaches for higher-resolution, higher output gain, better-linearity, and less-power-consumption micro-stimulator array. To achieve higher output gain for more ideal stimulus current without extra cascode stage, a gain-boosting design is adopted. To achieve higher-resolution and better linearity, a continuous pulse-width modulation-based conversion architecture has been proposed. To overcome extra power consumption of the baseband control logic, the energy recovery scheme is also applied. A monolithic circuitry of this efficient stimulator array has been realized by using TSMC 0.18-mum 1P6M standard CMOS technology and the experimental results show improvement over the prior approaches.

[1]  K Arabi,et al.  Electronic design of a multichannel programmable implant for neuromuscular electrical stimulation. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[2]  W. Liu,et al.  A neuro-stimulus chip with telemetry unit for retinal prosthetic device , 2000, IEEE Journal of Solid-State Circuits.

[3]  Frank Rattay,et al.  Effective electrode configuration for selective stimulation with inner eye prostheses , 2004, IEEE Transactions on Biomedical Engineering.

[4]  Shuenn-Yuh Lee,et al.  An implantable wireless bidirectional communication microstimulator for neuromuscular stimulation , 2005, IEEE Transactions on Circuits and Systems I: Regular Papers.

[5]  Oliver Chiu-sing Choy,et al.  Clock recovery circuit with adiabatic technology (quasi-static CMOS logic) , 2003, Proceedings of the 2003 International Symposium on Circuits and Systems, 2003. ISCAS '03..

[6]  Wentai Liu,et al.  An arbitrary waveform stimulus circuit for visual prostheses using a low-area multibias DAC , 2003, IEEE J. Solid State Circuits.

[7]  Kaushik Roy,et al.  QSERL: quasi-static energy recovery logic , 2001 .

[8]  Mohamad Sawan,et al.  Programmable high-amplitude balanced stimulus current-source for implantable microstimulators , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[9]  M. Samet,et al.  Programmable current source dedicated to a cochlear implant , 2004, First International Symposium on Control, Communications and Signal Processing, 2004..

[10]  J. Weiland,et al.  A variable range bi-phasic current stimulus driver circuitry for an implantable retinal prosthetic device , 2005, IEEE Journal of Solid-State Circuits.