Determination of water level effects on the dynamic characteristics of a prototype arch dam model using ambient vibration testing

This study investigated the water level effects on the dynamic characteristics of a prototype arch dam model using ambient vibration testing were investigated. Achievement of this purpose involved construction of a prototype arch dam-reservoir-foundation model under laboratory. The dam body was constructed with 60 cm height. Ambient vibration tests on the arch dam estimated its natural frequencies, mode shapes and damping ratios for different water levels. In the ambient vibration tests, ambient excitations are provided from small impact effects and the responses of the arch dam are measured. It can be stated from the study that natural frequencies are not overly changed among 0–30 cm water levels; however they are increased for higher water levels. The difference between the first natural frequencies of the arch dam obtained from empty reservoir (H = 0 cm) and full reservoir (H = 60 cm) is about 20–25%.

[1]  Alemdar Bayraktar,et al.  Water length and height effects on the earthquake behavior of arch dam-reservoir-foundation systems , 2011 .

[2]  G. R. Darbre,et al.  Natural frequencies measured from ambient vibration response of the arch dam of Mauvoisin , 2000 .

[3]  P. Paultre,et al.  An experimental investigation of water level effects on the dynamic behaviour of a large arch dam , 2001 .

[4]  Alemdar Bayraktar,et al.  Modal Parameter Identification of a Prototype Arch Dam Using Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification Techniques , 2010 .

[5]  H. Westergaard Water Pressures on Dams During Earthquakes , 1933 .

[6]  Deyu Li,et al.  Experimental study of seismic overloading of large arch dam , 2006 .

[7]  John F. Hall,et al.  System identification of a concrete arch dam and calibration of its finite element model , 2006 .

[8]  A. A. Dumanoglu,et al.  Reservoir water level effects on nonlinear dynamic response of arch dams , 2008 .

[9]  Nic Lane Aging Infrastructure: Dam Safety , 2008 .

[10]  Juan Carlos,et al.  Evaluation of structural damage identification methods based on dynamic characteristics , 2005 .

[11]  A. Chopra Earthquake Analysis of Arch Dams: Factors to Be Considered , 2012 .

[12]  Bart Peeters,et al.  Benchmark study on system identification through ambient vibration measurements , 2000 .

[13]  R. Cantieni,et al.  EXPERIMENTAL METHODS USED IN SYSTEM IDENTIFICATION OF CIVIL ENGINEERING STRUCTURES , 2004 .

[14]  Jean Proulx,et al.  Continuous ambient‐vibration monitoring of the arch dam of Mauvoisin , 2002 .

[15]  R. Dungar An efficient method of fluid–structure coupling in the dynamic analysis of structures , 1978 .

[16]  Z. C. He,et al.  Crack detection of arch dam using statistical neural network based on the reductions of natural frequencies , 2007 .

[17]  Colin Anthony Taylor,et al.  EFFECTIVE AMBIENT VIBRATION TESTING FOR VALIDATING NUMERICAL MODELS OF CONCRETE DAMS , 1999 .

[18]  Robert D. Adams,et al.  The location of defects in structures from measurements of natural frequencies , 1979 .

[19]  Edward L. Wilson,et al.  Finite elements for the dynamic analysis of fluid‐solid systems , 1983 .

[20]  Deyuan Li,et al.  Experimental study of dynamic damage of an arch dam , 2007 .

[21]  Randall J. Allemang,et al.  THE MODAL ASSURANCE CRITERION–TWENTY YEARS OF USE AND ABUSE , 2003 .