Fundamental Characterization of Conductive Intracardiac Communication for Leadless Multisite Pacemaker Systems

Objective: A new generation of leadless cardiac pacemakers effectively overcomes the main limitations of conventional devices, but only offer single-chamber pacing, although dual-chamber or multisite pacing is highly desirable for most patients. The combination of several leadless pacemakers could facilitate a leadless multisite pacemaker but requires an energy-efficient wireless communication for device synchronization. This study investigates the characteristics of conductive intracardiac communication between leadless pacemakers to provide a basis for future designs of leadless multisite pacemaker systems. Methods: Signal propagation and impedance behavior of blood and heart tissue were examined by in vitro and in vivo measurements on domestic pig hearts and by finite-element simulations in the frequency range of 1 kHz to 1 MHz. Results: A better signal transmission was obtained for frequencies higher than 10 kHz. The influence of a variety of practical parameters on signal transmission could be identified. A larger distance between pacemakers increases signal attenuation. A better signal transmission is obtained through larger inter-electrode distances and a larger electrode surface area. Furthermore, the influence of pacemaker encapsulation and relative device orientation was assessed. Conclusion: This study suggests that conductive intracardiac communication is well suited to be incorporated in leadless pacemakers. It potentially offers very low power consumption using low communication frequencies. Significance: The presented technique enables highly desired leadless multisite pacing in near future.

[1]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[2]  Peng Un Mak,et al.  A Novel Field-Circuit FEM Modeling and Channel Gain Estimation for Galvanic Coupling Real IBC Measurements , 2016, Sensors.

[3]  V. Reddy,et al.  Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review , 2017, Circulation.

[4]  Lluís Mont,et al.  2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). , 2013, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[5]  Michael Faulkner,et al.  Investigation of Galvanic-Coupled Intrabody Communication Using the Human Body Circuit Model , 2014, IEEE Journal of Biomedical and Health Informatics.

[6]  Wolfgang Fichtner,et al.  An Attempt to Model the Human Body as a Communication Channel , 2007, IEEE Transactions on Biomedical Engineering.

[7]  Lluís Mont,et al.  2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). , 2013, European heart journal.

[8]  Allen Taflove,et al.  Incorporation of the electrode–electrolyte interface into finite-element models of metal microelectrodes , 2008, Journal of neural engineering.

[9]  E. Neufeld,et al.  IT’IS Database for Thermal and Electromagnetic Parameters of Biological Tissues , 2012 .

[10]  Dudley J Pennell,et al.  Reference right atrial dimensions and volume estimation by steady state free precession cardiovascular magnetic resonance , 2013, Journal of Cardiovascular Magnetic Resonance.

[11]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[12]  E. T. McAdams,et al.  Harmonic analysis of low-frequency bioelectrode behavior , 2002, IEEE Transactions on Medical Imaging.

[13]  M. Mocanu,et al.  Retrograde heart perfusion: the Langendorff technique of isolated heart perfusion. , 2011, Journal of molecular and cellular cardiology.

[14]  Ilangko Balasingham,et al.  RF Channel Modeling for Implant-to-Implant Communication and Implant to Subcutaneous Implant Communication for Future Leadless Cardiac Pacemakers , 2018, IEEE Transactions on Biomedical Engineering.

[15]  Dudley J Pennell,et al.  Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance. , 2006, European heart journal.

[16]  S. Coates,et al.  The Strength‐Duration Curve and Its Importance in Pacing Efficiency: A Study of 325 Pacing Leads in 229 Patients , 2000, Pacing and clinical electrophysiology : PACE.

[17]  Paul A Friedman,et al.  Leadless Pacemakers - Implant, Explant and Long-Term Safety and Efficacy Data. , 2017, Journal of atrial fibrillation.

[18]  Karel G M Moons,et al.  Incidence and predictors of short- and long-term complications in pacemaker therapy: the FOLLOWPACE study. , 2012, Heart rhythm.

[19]  L. Geddes,et al.  Criteria for the Selection of Materials for Implanted Electrodes , 2003, Annals of Biomedical Engineering.

[20]  Wolfgang Fichtner,et al.  Signal Transmission by Galvanic Coupling Through the Human Body , 2010, IEEE Transactions on Instrumentation and Measurement.

[21]  Sunil K Dhar,et al.  Strength Duration Curve for Left Ventricular Epicardial Stimulation in Patients Undergoing Cardiac Resynchronization Therapy , 2009, Pacing and clinical electrophysiology : PACE.

[22]  Michael Faulkner,et al.  A Survey on Intrabody Communications for Body Area Network Applications , 2013, IEEE Transactions on Biomedical Engineering.

[23]  D. B. Heppner,et al.  Considerations of quasi-stationarity in electrophysiological systems. , 1967, The Bulletin of mathematical biophysics.

[24]  Javier Reina-Tosina,et al.  Distributed Circuit Modeling of Galvanic and Capacitive Coupling for Intrabody Communication , 2012, IEEE Transactions on Biomedical Engineering.

[25]  Kai Zhang,et al.  A Finite-Element Simulation of Galvanic Coupling Intra-Body Communication Based on the Whole Human Body , 2012, Sensors.

[26]  Jon Hamkins Pulse Position Modulation , 2011 .

[27]  Jian-Feng Zhao,et al.  A Review on Human Body Communication: Signal Propagation Model, Communication Performance, and Experimental Issues , 2017, Wirel. Commun. Mob. Comput..