Using accidental eccentricity in code-specified static and dynamic analyses of buildings
暂无分享,去创建一个
The differences between the increase in building response due to accidental eccentricity predicted by code-specified static and dynamic analyses are studied for symmetric and unsymmetric single and multistorey buildings. The increase in response computed from static analysis of the building is obtained by applying the equivalent static forces at distance e a , equal to the storey accidental eccentricity, from the centre of mass at each floor. Alternatively, this increase in response is computed by dynamic analysis of the building with the centre of mass of each floor shifted through a distance e a from its nominal position. A parametric study is performed on single-storey systems in order to evaluate the differences in response predicted by both analysis procedures.