Comparison of quantitative Y-90 SPECT and non-time-of-flight PET imaging in post-therapy radioembolization of liver cancer.
暂无分享,去创建一个
Martin A Lodge | Eric C Frey | Yinfeng Dong | Robert F Hobbs | Richard L Wahl | Xing Rong | R. Wahl | E. Frey | J. Geschwind | M. Lodge | R. Hobbs | Joseph M Herman | Thibault Mauxion | Diane K Reyes | T. Mauxion | D. Reyes | Jianting Yue | Jean-François H Geschwind | Xing Rong | Yinfeng Dong | J. Herman | J. Yue
[1] M Ljungberg,et al. Evaluation of quantitative 90Y SPECT based on experimental phantom studies , 2008, Physics in medicine and biology.
[2] A. Agrawal,et al. Comparative analysis of hepatopulmonary shunt obtained from pretherapy 99mTc MAA scintigraphy and post-therapy 90Y Bremsstrahlung imaging in 90Y microsphere therapy , 2012, Nuclear medicine communications.
[3] Max A. Viergever,et al. Quantitative Monte Carlo–Based 90Y SPECT Reconstruction , 2013, The Journal of Nuclear Medicine.
[4] Y. Kao,et al. Yttrium-90 internal pair production imaging using first generation PET/CT provides high-resolution images for qualitative diagnostic purposes. , 2012, The British journal of radiology.
[5] L. Tellmann,et al. PET imaging problems with the non-standard positron emitters Yttrium-86 and Iodine-124. , 2008, The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of....
[6] Donald W. Wilson,et al. Noise properties of the EM algorithm. I. Theory , 1994 .
[7] Y. Rolland,et al. Effectiveness of quantitative MAA SPECT/CT for the definition of vascularized hepatic volume and dosimetric approach: phantom validation and clinical preliminary results in patients with complex hepatic vascularization treated with yttrium-90-labeled microspheres , 2011, Nuclear medicine communications.
[8] Y. Rolland,et al. Dosimetry Based on 99mTc-Macroaggregated Albumin SPECT/CT Accurately Predicts Tumor Response and Survival in Hepatocellular Carcinoma Patients Treated with 90Y-Loaded Glass Microspheres: Preliminary Results , 2012, The Journal of Nuclear Medicine.
[9] Michael Ljungberg,et al. Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method. , 2012, Medical physics.
[10] B. Tsui,et al. Noise properties of the EM algorithm: II. Monte Carlo simulations. , 1994, Physics in medicine and biology.
[11] Eric C Frey,et al. Model-based compensation for quantitative 123I brain SPECT imaging , 2006, Physics in medicine and biology.
[12] G Sgouros,et al. Implementation and evaluation of patient-specific three-dimensional internal dosimetry. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[13] B. Zimmerman,et al. Experimental determination of calibration settings for plastic syringes containing solutions of 90Y using commercial radionuclide calibrators. , 2004, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.
[14] Wenzheng Feng,et al. Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for 90 Y microsphere brachytherapy in the treatment of hepatic malignancies. , 2011, Medical physics.
[15] R. Salem,et al. Internal Pair Production of 90Y Permits Hepatic Localization of Microspheres Using Routine PET: Proof of Concept , 2011, The Journal of Nuclear Medicine.
[16] C. Kuhl,et al. The Significance of 99mTc-MAA SPECT/CT Liver Perfusion Imaging in Treatment Planning for 90Y-Microsphere Selective Internal Radiation Treatment , 2010, The Journal of Nuclear Medicine.
[17] Marnix G. E. H. Lam,et al. Quantitative Comparison of PET and Bremsstrahlung SPECT for Imaging the In Vivo Yttrium-90 Microsphere Distribution after Liver Radioembolization , 2013, PloS one.
[18] Matthew S. Johnson,et al. The Impact of Image Reconstruction Bias on PET/CT 90Y Dosimetry After Radioembolization , 2014, The Journal of Nuclear Medicine.
[19] Michael Tapner,et al. A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres , 2015, European Journal of Nuclear Medicine and Molecular Imaging.
[20] S. Walrand,et al. Quantitation in PET using isotopes emitting prompt single gammas: application to yttrium-86 , 2003, European Journal of Nuclear Medicine and Molecular Imaging.
[21] Charles L. Byrne,et al. Noise characterization of block-iterative reconstruction algorithms. I. Theory , 2000, IEEE Transactions on Medical Imaging.
[22] Renaud Lhommel,et al. Yttrium-90 TOF PET scan demonstrates high-resolution biodistribution after liver SIRT , 2009, European Journal of Nuclear Medicine and Molecular Imaging.
[23] S. Vandenberghe,et al. Comparison of yttrium-90 quantitative imaging by TOF and non-TOF PET in a phantom of liver selective internal radiotherapy , 2011, Physics in medicine and biology.
[24] Michael Ljungberg,et al. 90Y Bremsstrahlung Imaging for Absorbed-Dose Assessment in High-Dose Radioimmunotherapy , 2010, The Journal of Nuclear Medicine.
[25] R. Wahl,et al. The utility of SPECT for 99mTc-MAA hepatic arterial perfusion scintigraphy. , 1985, AJR. American journal of roentgenology.
[26] Marnix G E H Lam,et al. 99mTc-Macroaggregated Albumin Poorly Predicts the Intrahepatic Distribution of 90Y Resin Microspheres in Hepatic Radioembolization , 2013, The Journal of Nuclear Medicine.