Dynamic Response of a 50 kW Organic Rankine Cycle System in Association with Evaporators

The influences of various evaporators on the system responses of a 50 kW ORC system using R-245fa are investigated in this study. First the effect of the supplied hot water flowrate into the evaporator is examined and the exit superheat on the system performance between plate and shell-and-tube evaporator is also reported. Test results show that the effect of hot water flowrate on the evaporator imposes a negligible effect on the transient response of the ORC system. These results prevail even for a 3.5-fold increase of the hot water flowrate and the system shows barely any change subject to this drastic hot water flowrate change. The effect of exit superheat on the ORC system depends on the type of the evaporator. For the plate evaporator, an exit superheat less than 10 °C may cause ORC system instability due to considerable liquid entrainment. To maintain a stable operation, the corresponding Jakob number of the plate heat evaporator must be above 0.07. On the other hand, by employing a shell and tube heat evaporator connected to the ORC system, no unstable oscillation of the ORC system is observed for exit superheats ranging from 0 to 17 °C.

[1]  Chi-Chuan Wang,et al.  Analysis of a 50 kW organic Rankine cycle system , 2011 .

[2]  N. Lai,et al.  Working fluids for high-temperature organic Rankine cycles , 2007 .

[3]  E. Stefanakos,et al.  A REVIEW OF THERMODYNAMIC CYCLES AND WORKING FLUIDS FOR THE CONVERSION OF LOW-GRADE HEAT , 2010 .

[4]  Li Zhao,et al.  Experimental investigation on the low-temperature solar Rankine cycle system using R245fa , 2011 .

[5]  Aleksandra Borsukiewicz-Gozdur Experimental investigation of R227ea applied as working fluid in the ORC power plant with hermetic turbogenerator , 2013 .

[6]  Li Zhao,et al.  An experimental study on the recuperative low temperature solar Rankine cycle using R245fa , 2012 .

[7]  Chi-Chuan Wang,et al.  Transient response of a 50 kW organic Rankine cycle system , 2012 .

[8]  Seok Hun Kang,et al.  Design and experimental study of ORC (organic Rankine cycle) and radial turbine using R245fa working fluid , 2012 .

[9]  J. E. Peters,et al.  An experimental investigation of entrained liquid carry-over from a serpentine evaporator , 1995 .

[10]  S. K. Wang,et al.  A Review of Organic Rankine Cycles (ORCs) for the Recovery of Low-grade Waste Heat , 1997 .

[11]  G. Kosmadakis,et al.  On site experimental evaluation of a low-temperature solar organic Rankine cycle system for RO desalination , 2009 .

[12]  Vincent Lemort,et al.  Experimental study and modeling of an Organic Rankine Cycle using scroll expander , 2010 .

[13]  G. L. Wedekind,et al.  A Generalization of the System Mean Void Fraction Model for Transient Two-Phase Evaporating Flows , 1981 .

[14]  Chi-Chuan Wang,et al.  Effect of working fluids on organic Rankine cycle for waste heat recovery , 2004 .

[15]  Farid Chejne,et al.  A technical, economical and market review of organic Rankine cycles for the conversion of low-grade heat for power generation , 2012 .