Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance.

PURPOSE/OBJECTIVE In radiotherapy of targets moving with respiration, beam gating is offered as a means of reducing the target motion. The purpose of this study is to evaluate the safe magnitude of margin reduction for respiratory gated beam delivery. MATERIALS/METHODS The study is based on data for 17 lung cancer patients in separate protocols at Rigshospitalet and Stanford Cancer Center. Respiratory curves for external optical markers and implanted fiducials were collected using equipment based on the RPM system (Varian Medical Systems). A total of 861 respiratory curves represented external measurements over 30 fraction treatment courses for 10 patients, and synchronous external/internal measurements in single sessions for seven patients. Variations in respiratory amplitude (simulated coaching) and external/internal phase shifts were simulated by perturbation with realistic values. Variations were described by medians and standard deviations (SDs) of position distributions of the markers. Gating windows (35% duty cycle) were retrospectively applied to the respiratory data for each session, mimicking the use of commercially available gating systems. Medians and SDs of gated data were compared to those of ungated data, to assess potential margin reductions. RESULTS External respiratory data collected over entire treatment courses showed SDs from 1.6 to 8.1mm, the major part arising from baseline variations. The gated data had SDs from 1.5 to 7.7mm, with a mean reduction of 0.3mm (6%). Gated distributions were more skewed than ungated, and in a few cases a marginal miss of gated respiration would be found even if no margin reduction was applied. Regularization of breathing amplitude to simulate coaching did not alter these results significantly. Simulation of varying phase shifts between internal and external respiratory signals showed that the SDs of gated distributions were the same as for the ungated or smaller, but the median values were markedly shifted. The gated distributions could generally not be covered by margins derived from ungated data, if the phase shift was not accounted for. CONCLUSIONS Margins can only be reduced for respiratory gated radiotherapy, if respiratory baseline shifts and variations in external/internal motion correlation are accounted for. Gated beam delivery alone cannot facilitate margin reduction. In the worst case, margins must be increased to accommodate inter-fraction variations in respiration.

[1]  Steve B. Jiang,et al.  Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates , 2005, Physics in medicine and biology.

[2]  Patrick A Kupelian,et al.  Evaluation of an infrared camera and X-ray system using implanted fiducials in patients with lung tumors for gated radiation therapy. , 2006, International journal of radiation oncology, biology, physics.

[3]  Hassan Mostafavi,et al.  Dynamic targeting image-guided radiotherapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[4]  Radhe Mohan,et al.  Patient training in respiratory-gated radiotherapy. , 2003, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[5]  A. Boyer,et al.  Comparison of respiratory surrogates for gated lung radiotherapy without internal fiducials , 2006, Acta oncologica.

[6]  Lena Specht,et al.  Intra- and interfraction breathing variations during curative radiotherapy for lung cancer. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  Jean-Philippe Pignol,et al.  Correlation of lung tumor motion with external surrogate indicators of respiration. , 2004, International journal of radiation oncology, biology, physics.

[8]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[9]  Hiroki Shirato,et al.  Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: a simulation study. , 2007, Medical physics.

[10]  Gikas S. Mageras,et al.  Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system , 2001, Journal of applied clinical medical physics.

[11]  R Mohan,et al.  Determining parameters for respiration-gated radiotherapy. , 2001, Medical physics.

[12]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.