The development of an on-chip micro-flow injection analysis of nitrate with a cadmium reductor

Abstract The development of a method to determine nitrate by micro-flow injection analysis (μFIA) is described, using electro-osmotic flow (EOF) control in a micro-chip with 300 μm wide and 115 μm deep channel wet etched in borosilicate glass. An in situ miniature copperised cadmium reductor column was produced by immobilisation within a micro-porous silica frit made from 10% formamide and 21% silicon dioxide. The reductor frit was located in the sample introduction reservoir of the device. Nitrate standards were placed in the sampling reservoir and an applied voltage of 50 V relative to a waste reservoir was used to move the nitrate ions through the reductor frit for μFIA. Silica frits without copperised cadmium were also introduced into the interconnecting channels of the μFIA device to promote EOF and minimise hydrodynamic movement of solutions. The nitrite produced on leaving the reductor frit was detected using the Griess diazo-coupling reaction. The reaction was monitored in situ using a micro-spectrometer. A calibration was obtained between 0.5 and 20 μM with a correlation coefficient of 0.985. The R.S.D. at 5 μM NO 3 − was 8.3% ( n =6) and the limit of detection (3 σ ) was 0.51 μM (0.026 μg ml −1 ) NO 3 − .

[1]  Z. Zhi-qi,et al.  Catalytic simultaneous spectrophotometric determination of nitrite and nitrate with a flow injection system , 1998 .

[2]  G. Kattner,et al.  Dissolved iron at subnanomolar levels in the Southern Ocean as determined by ship-board analysis , 1998 .

[3]  M. Sanada,et al.  Photo-induced reduction of nitrate to nitrite and its application to the sensitive determination of nitrate in natural waters , 1995 .

[4]  K. Horita,et al.  Column Preconcentration Analysis–Spectrophotometric Determination of Nitrate and Nitrite by a Diazotization–Coupling Reaction , 1997 .

[5]  N. G. Wilson,et al.  The fabrication of micro-porous silica structures for micro-reactor technology , 1998 .

[6]  A. Ensafi,et al.  Simultaneous determination of nitrite and nitrate in various samples using flow injection with spectrophotometric detection , 1999 .

[7]  V. Cerdà,et al.  Sequential injection sandwich technique for the simultaneous determination of nitrate and nitrite , 1998 .

[8]  P. Worsfold,et al.  Determination of sub-nanomolar levels of iron in seawater using flow injection with chemiluminescence detection , 1998 .

[9]  Vesselin N. Paunov,et al.  Theoretical considerations of chemical reactions in micro-reactors operating under electroosmotic and electrophoretic control , 1999 .

[10]  A. Manz,et al.  Microstructure for efficient continuous flow mixing , 1999 .

[11]  Gillian M. Greenway,et al.  Characterisation of a micro-total analytical system for the determination of nitrite with spectrophotometric detection , 1999 .

[12]  Toyoaki Aoki,et al.  Simultaneous flow injection determination of nitrate and nitrite in water by gas-phase chemiluminescence , 1995 .