Ultrashort TE chemical shift imaging (UTE‐CSI)

A fundamental modification to the conventional chemical shift imaging (CSI) method is described that improves the imaging of species with short T2's (i.e., less than ∼2 ms). This approach minimizes the delay before each k‐space point is collected. This results in different time delays, Td, for different free induction decay (FID) acquisitions in k‐space. On a clinical 1.5T system this yields an effective delay due to transmit/receive switching of 70 μs and an echo time (TE) from the center of the excitation pulse to the center of k‐space of 170 μs, as compared with 1–2 ms for conventional CSI techniques. Using this method, the signal decay before acquisition is greatly reduced, thus enabling imaging of species with very short T2 (e.g., 200 μs) and increasing the signal‐to‐noise ratio (SNR) of species with intermediate T2. Increases in the SNR of the short T2 components of 23Na in the heart, and 31P acquisitions of bone are about 27% and 400%, respectively, compared to an optimized conventional CSI approach. The imperfections of this approach are also described, and the magnitude of the resultant image artifacts is quantified for different practical imaging situations. These artifacts were not found to be significant in the described applications. This new method allows us to obtain information on short T2 components without degrading the image quality from long T2 components. Magn Reson Med 53:267–274, 2005. © 2005 Wiley‐Liss, Inc.

[1]  J Star-Lack,et al.  Reduced spatial side lobes in chemical‐shift imaging , 1999, Magnetic resonance in medicine.

[2]  D C Noll,et al.  MR imaging of lung parenchyma: a solution to susceptibility. , 1992, Radiology.

[3]  K. Uğurbil,et al.  NMR chemical shift imaging in three dimensions. , 1982, Proceedings of the National Academy of Sciences of the United States of America.

[4]  Albert Macovski,et al.  MR Spectroscopic imaging of collagen: Tendons and knee menisci , 1995, Magnetic resonance in medicine.

[5]  Andreas Greiser,et al.  Efficient k‐space sampling by density‐weighted phase‐encoding , 2003, Magnetic resonance in medicine.

[6]  F W Wehrli,et al.  Variable TE gradient and spin echo sequences for in Vivo MR microscopy of short T2 species , 1998, Magnetic resonance in medicine.

[7]  E. Dubois,et al.  Digital picture processing , 1985, Proceedings of the IEEE.

[8]  G M Bydder,et al.  Magnetic resonance imaging of short T2 components in tissue. , 2003, Clinical radiology.

[9]  Mark Bydder,et al.  Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging , 2003, Journal of computer assisted tomography.

[10]  J M Pauly,et al.  Lung parenchyma: projection reconstruction MR imaging. , 1991, Radiology.

[11]  P A Bottomley,et al.  Noninvasive quantification of total sodium concentrations in acute reperfused myocardial infarction using 23Na MRI , 2001, Magnetic resonance in medicine.