Experimental thermal investigation of an ONAN distribution transformer by fiber optic sensors

Abstract Transformers are considered as one of the main and high cost components of the power systems. This is due to the fact that their failure may have negative influence on sustainability and quality of energy. In addition, some failures may lead to high cost for replacement or repair and an unplanned outage of a power transformer is highly uneconomical. As a result, as a major equipment in power systems, its correct functioning is vital to enable efficient and reliable operation of electric power system. A transformer can fail due to any combination of electrical, mechanical or thermal stresses. The normal operation life of a transformer is partially related to the deterioration of its insulation through thermal ageing, which is determined mainly by its daily cyclic loadings. In this paper, heat analysis of a 1.5 MVA Oil-Natural Air-Natural cooling mode distribution transformer is experimentally investigated by equipped fiber optic sensors. The density of the fiber optic sensors is increased at the active parts in critical spots. Temperature measurements are realized according to the transformer losses variation and load variation tests. The thermal behavior of the distribution transformer is obtained. Contrary to the existing studies, the obtained results show that also the structure and the design of the transformer affects the hot-spot position and temperature.

[1]  C. Bengtsson,et al.  Status and trends in transformer monitoring , 1996 .

[2]  Xu Hao,et al.  Benefits of comprehensive and interactive on-line monitoring and expert systems for power transformers , 2008, 2008 International Conference on Condition Monitoring and Diagnosis.

[3]  Sheldon P. Kennedy,et al.  HOT SPOT STUDIES FOR SHEET WOUND TRANSFORMER WINDINGS , 2013 .

[4]  Paul Jarman,et al.  Evaluation of Power Transformers' Effective Hot-Spot Factors by Thermal Modeling of Scrapped Units , 2014, IEEE Transactions on Power Delivery.

[5]  D. Xue,et al.  Scaling of the anomalous Hall effect in ferrimagnetic Co90Gd10 thin films , 2015, 2015 IEEE Magnetics Conference (INTERMAG).

[6]  Zoran Radakovic,et al.  A new method for the calculation of the hot-spot temperature in power transformers with ONAN cooling , 2003 .

[7]  A. Gholami,et al.  Estimation of hot spot temperature in distribution transformer considering core design using FEM , 2008, 2008 IEEE 2nd International Power and Energy Conference.

[9]  M. P. Saravolac,et al.  The use of optic fibres for temperature monitoring in power transformers , 1994 .

[10]  S. Ho,et al.  A Novel Approach to Investigate the Hot-Spot Temperature Rise in Power Transformers , 2015, IEEE Transactions on Magnetics.

[11]  Erik Etien,et al.  Improving thermal model for oil temperature estimation in power distribution transformers , 2017 .

[13]  M.K. Pradhan,et al.  Estimation of the hottest spot temperature (HST) in power transformers considering thermal inhomogeniety of the windings , 2004, IEEE Transactions on Power Delivery.

[14]  J. Declercq,et al.  Accurate hot spot modeling in a power transformer leading to improved design and performance , 1999, 1999 IEEE Transmission and Distribution Conference (Cat. No. 99CH36333).

[15]  M. Lehtonen,et al.  Dynamic thermal modeling of distribution transformers , 2005, IEEE Transactions on Power Delivery.

[16]  Qian Xiangzhong,et al.  Notice of RetractionDesign of the power transformer winding hot spot temperature on-line detecting system , 2011, 2011 IEEE Power Engineering and Automation Conference.

[17]  M. Lehtonen,et al.  Dynamic thermal modelling of power transformers , 2004, IEEE Transactions on Power Delivery.

[18]  D. Sacerdotianu,et al.  Temperature control and monitoring system for power transformer windings using fiber optic sensors , 2016, 2016 International Symposium on Fundamentals of Electrical Engineering (ISFEE).

[19]  Suwarno,et al.  Transformer hot-spot temperature estimation for short-time dynamic loading , 2012, 2012 IEEE International Conference on Condition Monitoring and Diagnosis.

[20]  Antonio Pietrosanto,et al.  An enhanced fiber-optic temperature sensor system for power transformer monitoring , 2001, IEEE Trans. Instrum. Meas..

[21]  Jian Li,et al.  Hot spot temperature models based on top-oil temperature for oil immersed transformers , 2009, 2009 IEEE Conference on Electrical Insulation and Dielectric Phenomena.

[22]  K. A. Wickersheim,et al.  Direct Measurement of Transformer Winding Hot Spot Temperature , 1984, IEEE Power Engineering Review.

[23]  J.A. Jardini,et al.  Power transformer temperature evaluation for overloading conditions , 2005, IEEE Transactions on Power Delivery.

[24]  A. Das,et al.  Finite element method-based modelling of flow rate and temperature distribution in an oil-filled disc-type winding transformer using COMSOL multiphysics , 2017 .

[25]  F. Ortiz,et al.  Thermal degradation assessment of Kraft paper in power transformers insulated with natural esters , 2016 .

[26]  D. Susa,et al.  Thermal analysis of two transformers filled with different oils , 2014, IEEE Electrical Insulation Magazine.

[27]  Ronghui Huang,et al.  Oil-immersed transformer online hot spot temperature monitoring and accurate life lose calculation based on liber Bragg grating sensor technology , 2014, 2014 China International Conference on Electricity Distribution (CICED).

[28]  Dongjin Kweon,et al.  Hot spot temperature for 154 kV transformer filled with mineral oil and natural ester fluid , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[29]  James L. Kirtley,et al.  An improved transformer top oil temperature model for use in an on-line monitoring and diagnostic system , 1997 .