Sequential Injection Analysis Hyphenated with Other Flow Techniques: A Review

In the last two decades, sequential injection analysis (SIA) became an important automation tool in several analytical fields as it provided advantages in terms of versatility, robustness, and consumption of samples and reagents. The noteworthy versatility of an SIA selection valve allowed its association with several units, including devices typically associated with other flow techniques, resulting in generally better analytical performance. This review discusses the hyphenization of SIA with other flow approaches outlining its advantages and motivations, which are related mainly with sample manipulation and solutions management. The future trends and perspectives in this field are also addressed.

[1]  A. Anthemidis,et al.  On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples. , 2009, Talanta.

[2]  M. Trojanowicz Advances in Flow Analysis , 2008 .

[3]  F. Brockman,et al.  Rotating rod renewable microcolumns for automated, solid-phase DNA hybridization studies. , 2000, Analytical Chemistry.

[4]  A. Sabarudin,et al.  Sequential-injection on-line preconcentration using chitosan resin functionalized with 2-amino-5-hydroxy benzoic acid for the determination of trace elements in environmental water samples by inductively coupled plasma-atomic emission spectrometry. , 2007, Talanta.

[5]  M. Miró,et al.  Hyphenating multisyringe flow injection lab-on-valve analysis with atomic fluorescence spectrometry for on-line bead injection preconcentration and determination of trace levels of hydride-forming elements in environmental samples. , 2006, Analytical Chemistry.

[6]  A. Araújo,et al.  Exploiting sequential injection analysis with lab-on-valve and miniaturized potentiometric detection Epinephrine determination in pharmaceutical products. , 2007, Talanta.

[7]  P. Pinto,et al.  Fluorimetric determination of aminocaproic acid in pharmaceutical formulations using a sequential injection analysis system. , 2006, Talanta.

[8]  R. Peña,et al.  Sequential injection analysis-based flow system for the enzymatic determination of aspartame , 2004 .

[9]  A. Anthemidis Automatic sequential injection liquid–liquid micro-extraction system for on-line flame atomic absorption spectrometric determination of trace metal in water samples , 2008 .

[10]  M. Casasa,et al.  Rapid 90 Sr = 90 Y determination in water samples using a sequential injection method , 2022 .

[11]  Jianhua Wang,et al.  Coupling sequential injection on-line preconcentration using a PTFE beads packed column to direct injection nebulization inductively coupled plasma mass spectrometry , 2002 .

[12]  Celio Pasquini,et al.  Chloride-selective membrane electrodes and optodes based on an indium(III) porphyrin for the determination of chloride in a sequential injection analysis system. , 2004, Journal of Pharmaceutical and Biomedical Analysis.

[13]  G. Theodoridis,et al.  Automated sample preparation based on the sequential injection principle. Solid-phase extraction on a molecularly imprinted polymer coupled on-line to high-performance liquid chromatography. , 2004, Journal of chromatography. A.

[14]  Jianhua Wang,et al.  FI/SI on-line solvent extraction/back extraction preconcentration coupled to direct injection nebulization inductively coupled plasma mass spectrometry for determination of copper and lead , 2002 .

[15]  G. Christian,et al.  Sequential injection wetting film extraction applied to the spectrophotometric determination of chromium(VI) and chromium(III) in water. , 1997, Talanta.

[16]  M. Miró,et al.  Sequential injection 90Sr determination in environmental samples using a wetting-film extraction method. , 2002, Analytical chemistry.

[17]  J. March,et al.  An environmental friendly method for the automatic determination of hypochlorite in commercial products using multisyringe flow injection analysis. , 2008, Analytica chimica acta.

[18]  A. Voulgaropoulos,et al.  Coupling of sequential injection with liquid chromatography for the automated derivatization and on-line determination of amino acids. , 2006, Talanta.

[19]  M. Sales,et al.  Multi-task flow system for potentiometric analysis: its application to the determination of vitamin B6 in pharmaceuticals. , 2001, Journal of pharmaceutical and biomedical analysis.

[20]  M. Catalá Icardo,et al.  Multicommutation as a powerful new analytical tool , 2002 .

[21]  S. Chough,et al.  Sequential injection analysis system for on-line monitoring of l-cysteine concentration in biological processes. , 2005, Talanta.

[22]  H. Shu,et al.  Flow Binding Assay Using Sequential Injection Analysis for Bioprocess Monitoring , 2000 .

[23]  O. Egorov,et al.  Investigation and Optimization of On-Column Redox Reactions in the Sorbent Extraction Separation of Americium and Plutonium Using Flow Injection Analysis , 1998 .

[24]  J. Lima,et al.  Application of Sequential Injection Analysis to the Determination of Cationic Surfactants Based on the Sensitized Molybdenum-Bromopyrogallol Red Reaction , 2005, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[25]  I. Díez,et al.  Simultaneous determination of potassium and total fluoride in toothpastes using a SIA system with two potentiometric detectors. , 2008, Journal of pharmaceutical and biomedical analysis.

[26]  P. Solich,et al.  Ion selective electrodes for penicillin-G based on Mn(III)TPP-Cl and their application in pharmaceutical formulations control by sequential injection analysis. , 2004, Journal of pharmaceutical and biomedical analysis.

[27]  Jianhua Wang,et al.  Flow Injection On-Line Two-Stage Solvent Extraction Preconcentration Coupled with Et-Aas for Determination of Bismuth in Biological and Environmental Samples , 2000 .

[28]  M. Sales,et al.  Potentiometric determination of acetylsalicylic acid by sequential injection analysis (SIA) using a tubular salicylate-selective electrode. , 2001, Journal of pharmaceutical and biomedical analysis.

[29]  A. Araújo,et al.  Sequential injection system in flame atomic absorption spectrometry for the determination of calcium and magnesium in mineral waters , 1998 .

[30]  Agostinho Santos,et al.  Estimation of postmortem interval by hypoxanthine and potassium evaluation in vitreous humor with a sequential injection system. , 2009, Talanta.

[31]  J. Lima,et al.  Determination and antioxidant activity evaluation of etodolac, an anti-inflammatory drug, by sequential injection analysis. , 2006, Analytica chimica acta.

[32]  V. Cerdà,et al.  Flow techniques in water analysis. , 1999, Talanta.

[33]  D. Yuan,et al.  Sequential injection analysis of nanomolar soluble reactive phosphorus in seawater with HLB solid phase extraction , 2008 .

[34]  M. Pimentel,et al.  Sequential injection analysis of chloride and nitrate in waters with improved accuracy using potentiometric detection. , 2004, Talanta.

[35]  A. Voulgaropoulos,et al.  On-line coupling of sequential injection with liquid chromatography for the automated derivatization and determination of gamma-aminobutyric acid in human biological fluids. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[36]  E. Hansen,et al.  Sequential injection on-line matrix removal and trace metal preconcentration using a PTFE beads packed column as demonstrated for the determination of cadmium by electrothermal atomic absorption spectrometry , 2002 .

[37]  J. Lima,et al.  Multicommutation in flow analysis. Part 1. Binary sampling: concepts, instrumentation and spectrophotometric determination of iron in plant digests , 1994 .

[38]  J. Lima,et al.  Multi-commutation in flow analysis: recent developments and applications. , 2008, Analytica chimica acta.

[39]  A. Araújo,et al.  Development of a sequential injection analysis system for the potentiometric determination of nitrite in meat products by using a Gran’s plot method , 2009 .

[40]  V. Cerdà,et al.  Gas diffusion techniques coupled sequential injection analysis for selective determination of ammonium , 1996 .

[41]  J. Ruzicka,et al.  Flow injection analyses , 1975 .

[42]  V. Cerdà,et al.  Preconcentration by flow reversal in conductometric sequential injection analysis of ammonium , 1996 .

[43]  G. Christian,et al.  Sequential Injection Photometric Determination of Molybdenum Using Organic Wetting Film Extraction , 1997 .

[44]  G. Christian,et al.  Flow/sequential injection determination of gaseous ammonia with a glass diffusion denuder. , 1995, Talanta.

[45]  M. Miró,et al.  Online coupling of bead injection lab-on-valve analysis to gas chromatography: application to the determination of trace levels of polychlorinated biphenyls in solid waste leachates. , 2009, Analytical chemistry.

[46]  J. Lima,et al.  Sample preparation in sequential injection analysis. Spectrophotometric determination of total phosphorus in food samples , 1998 .

[47]  Anastasios Economou,et al.  Bismuth-film electrodes: recent developments and potentialities for electroanalysis , 2005 .

[48]  S. Motomizu,et al.  Pre-evaluation of metal ions as a catalyst on chemiluminometric sequential injection analysis with luminol-H2O2 system. , 2009, Talanta: The International Journal of Pure and Applied Analytical Chemistry.

[49]  B. Mattiasson,et al.  Sequential Injection Analysis of Ethanol Using Immobilized Alcohol Dehydrogenase. , 1996 .

[50]  Víctor Cerdà,et al.  Completely automated system for determining halogenated organic compounds by multisyringe flow injection analysis. , 2008, Analytical chemistry.

[51]  J. Lima,et al.  A pulsed sequential injection analysis flow system for the fluorimetric determination of indomethacin in pharmaceutical preparations , 2005 .

[52]  V. L. Silva,et al.  Sequential preconcentration for the ETAAS determination of Pd in human urine , 2002 .

[53]  Jian-Hua Wang,et al.  On-line sample-pre-treatment schemes for trace-level determinations of metals by coupling flow injection or sequential injection with ICP-MS , 2003 .

[54]  A. Araújo,et al.  Simultaneous Determination of Potassium and Nitrate Ions in Mouthwashes Using Sequential Injection Analysis with Potentiometric Detection , 2008, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[55]  G. Christian,et al.  Sequential injection analysis with dynamic surface tension detection High throughput analysis of the interfacial properties of surface-active samples. , 2003, Talanta.

[56]  B. Lendl,et al.  Automated sample preparation and analysis using a sequential-injection-capillary electrophoresis (SI-CE) interface. , 2006, The Analyst.

[57]  Jaromir Růžička,et al.  Flow injection analysis , 1981 .

[58]  U. Sansone,et al.  Development and application of an on-line sequential injection system for the separation of Pu, 210Po and 210Pb from environmental samples. , 2008, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[59]  A. Economou Sequential-injection analysis (SIA): A useful tool for on-line sample-handling and pre-treatment , 2005 .

[60]  V. Cerdà,et al.  A multisyringe sequential injection method for monitoring water in the energy cogeneration system of a municipal waste incinerator. , 2009, Talanta.

[61]  A. O. Rangel,et al.  Sequential injection flow system with improved sample throughput: determination of glycerol and ethanol in wines , 2002 .

[62]  A. Araújo,et al.  Metals Determination in Wines by Sequential Injection Analysis With Flame Atomic Absorption Spectrometry , 2000, American Journal of Enology and Viticulture.

[63]  Carolina Arnau,et al.  Monitoring of sorbitol in Pichia pastoris cultivation applying sequential injection analysis , 2008 .

[64]  E. Zagatto,et al.  Microwave-assisted sample preparation in sequential injection: spectrophotometric determination of magnesium, calcium and iron in food , 2000 .

[65]  V. Cerdà,et al.  A robust multisyringe system for process flow analysis. Part II. A multi-commuted injection system applied to the photometric determination of free acidity and iron(III) in metallurgical solutions. , 2000, The Analyst.

[66]  A. Araújo,et al.  A sequential injection analysis system for potassium clavulanate determination using two potentiometric detectors. , 2002, Journal of pharmaceutical and biomedical analysis.

[67]  M. Segundo,et al.  Multisyringe Flow Injection Analysis: State-of-the-Art and Perspectives , 2006, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[68]  J. Lima,et al.  Enzymatic oxidation in aqueous and micellar media based on horseradish peroxidase-hydrogen peroxide system using a SIA manifold , 2008 .

[69]  F. Tureček,et al.  Automated affinity chromatography measurements of compound mixtures using a lab-on-valve apparatus coupled to electrospray ionization mass spectrometry. , 2004, Analytical biochemistry.

[70]  G. Zachariadis,et al.  Development of a sequential injection system for trace mercury determination by cold vapour atomic absorption spectrometry utilizing an integrated gas-liquid separator/reactor. , 2004, Talanta.

[71]  Jianhua Wang,et al.  Trends and perspectives of flow injection/sequential injection on-line sample-pretreatment schemes coupled to ETAAS , 2005 .

[72]  L. Skeggs An automatic method for colorimetric analysis. , 1957, American journal of clinical pathology.

[73]  Roongrat Chomchoei,et al.  Evaluation of a novel PTFE material for use as a means for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems , 2004 .

[74]  J. Ruzicka,et al.  Sequential injection: a new concept for chemical sensors, process analysis and laboratory assays , 1990 .

[75]  J. Grate,et al.  Radionuclide sensors based on chemically selective scintillating microspheres:  renewable column sensor for analysis of (99)tc in water. , 1999, Analytical chemistry.

[76]  J. Grate,et al.  Sequential Injection Renewable Separation Column Instrument for Automated Sorbent Extraction Separations of Radionuclides , 1998 .

[77]  M. Bezerra,et al.  Development of a new sequential injection in-line cloud point extraction system for flame atomic absorption spectrometric determination of manganese in food samples. , 2008, Talanta.

[78]  N. Reyes,et al.  Development of hardware and software for on-line sample preparation using sequential-injection analysis , 2000 .

[79]  M. Miró,et al.  Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis. , 2006, Analytical chemistry.

[80]  J. Ruzicka Lab-on-valve: universal microflow analyzer based on sequential and bead injection , 2000 .

[81]  A. Almeida,et al.  Determination of Rh, Pd and Pt in urine samples using a pre-concentration sequential injection analysis system coupled to a quadrupole-inductively coupled plasma-mass spectrometer. , 2007, Analytica chimica acta.

[82]  A. Araújo,et al.  Sequential injection analysis of lead using time-based colorimetric detection and preconcentration on an anionic-exchange resin. , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[83]  M. Miró,et al.  A multisyringe flow-through sequential extraction system for on-line monitoring of orthophosphate in soils and sediments. , 2007, Talanta.

[84]  B. Lendl,et al.  Sheath-flow Fourier transform infrared spectrometry for the simultaneous determination of citric, malic and tartaric acids in soft drinks , 2000 .

[85]  Frank Vogt,et al.  A UV spectroscopic method for monitoring aromatic hydrocarbons dissolved in water , 2000 .

[86]  O. Elsholz,et al.  Multisyringe flow injection analysis coupled to capillary electrophoresis (MSFIA-CE) as a novel analytical tool applied to the pre-concentration, separation and determination of nitrophenols. , 2008, Talanta.

[87]  V. L. Silva,et al.  Cyclodextrin-based potentiometric sensors for midazolam and diazepam. , 2008, Journal of pharmaceutical and biomedical analysis.

[88]  Yongliang Yu,et al.  Determination of Copper in Seawater Using a Sequential Injection System Incorporating a Sample Pretreatment Module Coupled to Electrothermal Atomic Absorption Spectrometry , 2007 .

[89]  P. Pinto,et al.  An enzymatic flow analysis methodology for the determination of nitrates and nitrites in waters , 2005 .

[90]  A. Araújo,et al.  Application of Sequential Injection Analysis to the Assay of Lead Retention Characteristics by Poly(vinylpyrrolidone):Trace Analysis of Lead in Waters , 1999 .

[91]  Víctor Cerdà,et al.  A robust multisyringe system for process flow analysis. Part I. On-line dilution and single point titration of protolytes , 1999 .

[92]  A. Araújo,et al.  Determination of Fe(III) and total Fe in wines by sequential injection analysis and flame atomic absorption spectrometry , 2001 .

[93]  J. Grate,et al.  Sequential injection separation system with stopped-flow radiometric detection for automated analysis of (99)tc in nuclear waste. , 1998, Analytical Chemistry.

[94]  J. Lima,et al.  Determination of total and oxidized glutathione in human whole blood with a sequential injection analysis system. , 2008, Talanta.

[95]  P. Pinto,et al.  Sequential injection analysis of nitrites and nitrates in human serum using nitrate reductase. , 2003, Clinica chimica acta; international journal of clinical chemistry.

[96]  V. Cerdà,et al.  Rapid determination in water samples using a sequential injection method , 2000 .

[97]  S. Reis,et al.  Automatic sequential determination of the hydrogen peroxide scavenging activity and evaluation of the antioxidant potential by the 2,2′-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) radical cation assay in wines by sequential injection analysis , 2005 .

[98]  J. Grate,et al.  Separation-optimized sequential injection method for rapid automated analytical separation of 90Sr in nuclear waste , 1999 .

[99]  A. Sabarudin,et al.  Automated Online Preconcentration System for the Determination of Trace Amounts of Lead Using Pb‐Selective Resin and Inductively Coupled Plasma–Atomic Emission Spectrometry , 2006 .

[100]  J. Grate,et al.  Automated extraction chromatographic separations of actinides using separation-optimized sequential injection techniques , 1999 .

[101]  M. Miró,et al.  A multisyringe flow injection system with immobilized glucose oxidase based on homogeneous chemiluminescence detection , 2004 .

[102]  A. Anthemidis,et al.  Development of on-line single-drop micro-extraction sequential injection system for electrothermal atomic absorption spectrometric determination of trace metals. , 2009, Analytica chimica acta.

[103]  M. Miró,et al.  Automated sequential injection-microcolumn approach with on-line flame atomic absorption spectrometric detection for implementing metal fractionation schemes of homogeneous and nonhomogeneous solid samples of environmental interest. , 2005, Analytical chemistry.

[104]  Jianhua Wang,et al.  Interfacing sequential injection on-line preconcentration using a renewable micro-column incorporated in a ‘lab-on-valve’ system with direct injection nebulization inductively coupled plasma mass spectrometry , 2001 .

[105]  J. Castillo,et al.  Performance of different preconcentration columns used in sequential injection analysis and inductively coupled plasma-mass spectrometry for multielemental determination in seawater ☆ , 2002 .

[106]  S. Nielsen,et al.  Interfacing flow injection analysis (sequential injection analysis) and electro-thermal atomic absorption spectrometry determination of trace-levels of Cr(VI) via on-line pre-concentration by adsorption in a knotted reactor and by liquid–liquid extraction , 2000 .

[107]  E. Hansen,et al.  Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry , 2002 .

[108]  M. Gelb,et al.  Automated affinity capture-release of biotin-containing conjugates using a lab-on-valve apparatus coupled to UV/visible and electrospray ionization mass spectrometry. , 2002, Analytical chemistry.

[109]  P. Pinto,et al.  A flow sampling strategy for the analysis of oil samples without pre-treatment in a sequential injection analysis system , 2006 .

[110]  O. Elsholz,et al.  On-line determination of mercury in river water at the German monitoring station Schnackenburg/Elbe , 2000, Fresenius' journal of analytical chemistry.

[111]  J. Janata,et al.  Automated Analysis of Radionuclides in Nuclear Waste: Rapid Determination of 90Sr by Sequential Injection Analysis , 1996 .

[112]  D. Yuan,et al.  In-field determination of nanomolar nitrite in seawater using a sequential injection technique combined with solid phase enrichment and colorimetric detection. , 2008, Analytica chimica acta.

[113]  Elo Harald Hansen,et al.  Flow injection analysis : Part X. theory, techniques and trends , 1978 .

[114]  Bo Mattiasson,et al.  On-line monitoring of D-lactic acid during a fermentation process using immobilized D-lactate dehydrogenase in a sequential injection analysis system☆ , 1995 .

[115]  J. Lima,et al.  Multi-pumping in flow analysis: concepts, instrumentation, potentialities , 2002 .

[116]  P. Solich,et al.  Sequential injection system for simultaneous determination of chloride and iodide by a Gran's plot method , 2004 .

[117]  Claire E Lenehan,et al.  Sequential injection analysis. , 2002, The Analyst.

[118]  Alberto N. Araújo,et al.  Application of sequential injection analysis (SIA) to food analysis , 2005 .