A closed-form differential formulation for ultrasound spatial calibration: single wall phantom.
暂无分享,去创建一个
Purang Abolmaesumi | Robert Rohling | Narges Afsham | Mohammad Najafi | R. Rohling | P. Abolmaesumi | M. Najafi | N. Afsham
[1] F. Lindseth,et al. Accuracy evaluation of a 3D ultrasound-based neuronavigation system. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.
[2] J. Trobaugh,et al. Frameless stereotactic ultrasonography: method and applications. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.
[3] Stefan Weber,et al. A fully automatic calibration framework for navigated ultrasound imaging , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.
[4] Guido Gerig,et al. Medical Image Computing and Computer-Assisted Intervention - MICCAI 2005, 8th International Conference, Palm Springs, CA, USA, October 26-29, 2005, Proceedings, Part II , 2005, MICCAI.
[5] W. Walker,et al. A fundamental limit on delay estimation using partially correlated speckle signals , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[6] Makoto Hashizume,et al. Intraoperative Magnetic Tracker Calibration Using a Magneto-Optic Hybrid Tracker for 3-D Ultrasound-Based Navigation in Laparoscopic Surgery , 2008, IEEE Transactions on Medical Imaging.
[7] Eigil Samset,et al. A motion constrained cross-wire phantom for tracked 2D ultrasound calibration , 2011, International Journal of Computer Assisted Radiology and Surgery.
[8] C. Loan,et al. Approximation with Kronecker Products , 1992 .
[9] R W Prager,et al. Rapid calibration for 3-D freehand ultrasound. , 1998, Ultrasound in medicine & biology.
[10] G Bashein,et al. 3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. , 1994, Ultrasound in medicine & biology.
[11] Xishi Huang,et al. Image registration based 3D TEE-EM calibration , 2010, 2010 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.
[12] Richard W Prager,et al. A mechanical instrument for 3D ultrasound probe calibration. , 2005, Ultrasound in medicine & biology.
[13] Gregory D. Hager,et al. Ultrasound self-calibration , 2006, SPIE Medical Imaging.
[14] S. Winter,et al. A SIMPLE AND ACCURATE CALIBRATION METHOD FOR 3 D FREEHAND ULTRASOUND , 2004 .
[15] M. V. D. van der Linden,et al. Ultrasound-guided breast-sparing surgery to improve cosmetic outcomes and quality of life. A prospective multicentre randomised controlled clinical trial comparing ultrasound-guided surgery to traditional palpation-guided surgery (COBALT trial) , 2011, BMC surgery.
[16] Thomas Lange,et al. Automatic Calibration of 3D Ultrasound Probes , 2011, Bildverarbeitung für die Medizin.
[17] Rémi Souchon,et al. Transrectal high-intensity focused ultrasound ablation of prostate cancer: effective treatment requiring accurate imaging. , 2007, European journal of radiology.
[18] Ziv Yaniv,et al. Ultrasound calibration framework for the image-guided surgery toolkit (IGSTK) , 2011, Medical Imaging.
[19] Andras Lasso,et al. Implementation of the PLUS open-source toolkit for translational research of ultrasound-guided intervention systems , 2012, The MIDAS Journal.
[20] Robert B. Fisher,et al. Estimating 3-D rigid body transformations: a comparison of four major algorithms , 1997, Machine Vision and Applications.
[21] Po-Wei Hsu,et al. Comparison of freehand 3-D ultrasound calibration techniques using a stylus. , 2008, Ultrasound in medicine & biology.
[22] Rakesh Patel,et al. 3D-Ultrasound Guided Radiation Therapy in the Post-Prostatectomy Setting , 2003, Technology in cancer research & treatment.
[23] Purang Abolmaesumi,et al. A real-time freehand ultrasound calibration system with automatic accuracy feedback and control. , 2009, Ultrasound in medicine & biology.
[24] Purang Abolmaesumi,et al. A Closed-Form Differential Formulation for Ultrasound Spatial Calibration , 2012, IPCAI.
[25] D M Muratore,et al. Beam calibration without a phantom for creating a 3-D freehand ultrasound system. , 2001, Ultrasound in medicine & biology.
[26] N Pagoulatos,et al. A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer. , 2001, Ultrasound in medicine & biology.
[27] Laurence Mercier,et al. A review of calibration techniques for freehand 3-D ultrasound systems. , 2005, Ultrasound in medicine & biology.
[28] D. Louis Collins,et al. Towards accurate, robust and practical ultrasound-CT registration of vertebrae for image-guided spine surgery , 2011, International Journal of Computer Assisted Radiology and Surgery.
[29] Purang Abolmaesumi,et al. A closed-form differential formulation for ultrasound spatial calibration: multi-wedge phantom. , 2014, Ultrasound in medicine & biology.
[30] Thomas Langø,et al. Probe calibration for freehand 3-D ultrasound. , 2003, Ultrasound in medicine & biology.
[31] Hans-Peter Meinzer,et al. Comparing calibration approaches for 3D ultrasound probes , 2008, International Journal of Computer Assisted Radiology and Surgery.
[32] Daniel Rueckert,et al. An Image Registration Approach to Automated Calibration for Freehand 3D Ultrasound , 2000, MICCAI.
[33] G. Unsgaard,et al. Surgical Resection of High-grade Gliomas in Eloquent Regions Guided by Blood Oxygenation Level Dependent Functional Magnetic Resonance Imaging, Diffusion Tensor Tractography, and Intraoperative Navigated 3D Ultrasound , 2009, Minimally invasive neurosurgery : MIN.
[34] Russell H. Taylor,et al. Information Processing in Computer-Assisted Interventions - Second International Conference, IPCAI 2011, Berlin, Germany, June 22, 2011. Proceedings , 2011, IPCAI.
[35] Russell H. Taylor,et al. A novel closed form solution for ultrasound calibration , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).
[36] M. Genton. Separable approximations of space‐time covariance matrices , 2007 .
[37] Andrew H. Gee,et al. Stradx: real-time acquisition and visualization of freehand three-dimensional ultrasound , 1999, Medical Image Anal..
[38] Marco Caversaccio,et al. On the Development and Comparative Evaluation of an Ultrasound B-Mode Probe Calibration Method , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.
[39] Morgan Sangeux,et al. Validation of 3-D freehand ultrasound for the determination of the hip joint centre. , 2010, Gait & posture.
[40] Fernando Arambula Cosio,et al. Computer assisted biopsy of breast tumors , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.
[41] Takeo Kanade,et al. Calibration Method for Determining the Physical Location of the Ultrasound Image Plane , 2001, MICCAI.
[42] Rémi Souchon,et al. Transrectal high-intensity focused ultrasound ablation of prostate cancer: effective treatment requiring accurate imaging. , 2007 .
[43] Po-Wei Hsu,et al. Real-time freehand 3D ultrasound calibration. , 2008, Ultrasound in medicine & biology.
[44] Branislav Jaramaz,et al. Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000 , 2000, Lecture Notes in Computer Science.
[45] Purang Abolmaesumi,et al. Single wall closed-form differential ultrasound calibration , 2012, Medical Imaging.
[46] Jorge J. Moré,et al. The Levenberg-Marquardt algo-rithm: Implementation and theory , 1977 .
[47] Alfonso Mejia,et al. Ultrasound-guided management of hand fractures. , 2008, Orthopedics.
[48] Po-Wei Hsu,et al. Freehand 3D Ultrasound Calibration: A Review , 2009 .
[49] Frank Sauer,et al. A Novel Phantom-Less Spatial and Temporal Ultrasound Calibration Method , 2005, MICCAI.