A closed-form differential formulation for ultrasound spatial calibration: single wall phantom.

Calibration is essential in freehand 3-D ultrasound to find the spatial transformation from the image coordinates to the sensor coordinate system. Ease of use, simplicity, precision and accuracy are among the most important factors in ultrasound calibration, especially when aiming to make calibration more reliable for day-to-day clinical use. We introduce a new mathematical framework for the simple and popular single-wall calibration phantom with a plane equation pre-determination step and the use of differential measurements to obtain accurate measurements. The proposed method provides a novel solution for ultrasound calibration that is accurate and easy to perform. This method is applicable to both radiofrequency (RF) and B-mode data, and both linear and curvilinear transducers. For a linear L14-5 transducer, the point reconstruction accuracy (PRA) of reconstructing 370 points is 0.73 ± 0.23 mm using 100 RF images, whereas the triple N-wire PRA is 0.67 ± 0.20 mm using 100 B-mode images. For a curvilinear C5-2 transducer, the PRA using the proposed method is 0.86 ± 0.28 mm on 400 points using 100 RF images, whereas N-wire calibration gives a PRA of 0.80 ± 0.46 mm using 100 B-mode images. Therefore, the accuracy of the proposed variation of the single-wall method using RF data is practically similar to the N-wire method while offering a simpler phantom with no need for accurate design and construction.

[1]  F. Lindseth,et al.  Accuracy evaluation of a 3D ultrasound-based neuronavigation system. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[2]  J. Trobaugh,et al.  Frameless stereotactic ultrasonography: method and applications. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[3]  Stefan Weber,et al.  A fully automatic calibration framework for navigated ultrasound imaging , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[4]  Guido Gerig,et al.  Medical Image Computing and Computer-Assisted Intervention - MICCAI 2005, 8th International Conference, Palm Springs, CA, USA, October 26-29, 2005, Proceedings, Part II , 2005, MICCAI.

[5]  W. Walker,et al.  A fundamental limit on delay estimation using partially correlated speckle signals , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Makoto Hashizume,et al.  Intraoperative Magnetic Tracker Calibration Using a Magneto-Optic Hybrid Tracker for 3-D Ultrasound-Based Navigation in Laparoscopic Surgery , 2008, IEEE Transactions on Medical Imaging.

[7]  Eigil Samset,et al.  A motion constrained cross-wire phantom for tracked 2D ultrasound calibration , 2011, International Journal of Computer Assisted Radiology and Surgery.

[8]  C. Loan,et al.  Approximation with Kronecker Products , 1992 .

[9]  R W Prager,et al.  Rapid calibration for 3-D freehand ultrasound. , 1998, Ultrasound in medicine & biology.

[10]  G Bashein,et al.  3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. , 1994, Ultrasound in medicine & biology.

[11]  Xishi Huang,et al.  Image registration based 3D TEE-EM calibration , 2010, 2010 IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[12]  Richard W Prager,et al.  A mechanical instrument for 3D ultrasound probe calibration. , 2005, Ultrasound in medicine & biology.

[13]  Gregory D. Hager,et al.  Ultrasound self-calibration , 2006, SPIE Medical Imaging.

[14]  S. Winter,et al.  A SIMPLE AND ACCURATE CALIBRATION METHOD FOR 3 D FREEHAND ULTRASOUND , 2004 .

[15]  M. V. D. van der Linden,et al.  Ultrasound-guided breast-sparing surgery to improve cosmetic outcomes and quality of life. A prospective multicentre randomised controlled clinical trial comparing ultrasound-guided surgery to traditional palpation-guided surgery (COBALT trial) , 2011, BMC surgery.

[16]  Thomas Lange,et al.  Automatic Calibration of 3D Ultrasound Probes , 2011, Bildverarbeitung für die Medizin.

[17]  Rémi Souchon,et al.  Transrectal high-intensity focused ultrasound ablation of prostate cancer: effective treatment requiring accurate imaging. , 2007, European journal of radiology.

[18]  Ziv Yaniv,et al.  Ultrasound calibration framework for the image-guided surgery toolkit (IGSTK) , 2011, Medical Imaging.

[19]  Andras Lasso,et al.  Implementation of the PLUS open-source toolkit for translational research of ultrasound-guided intervention systems , 2012, The MIDAS Journal.

[20]  Robert B. Fisher,et al.  Estimating 3-D rigid body transformations: a comparison of four major algorithms , 1997, Machine Vision and Applications.

[21]  Po-Wei Hsu,et al.  Comparison of freehand 3-D ultrasound calibration techniques using a stylus. , 2008, Ultrasound in medicine & biology.

[22]  Rakesh Patel,et al.  3D-Ultrasound Guided Radiation Therapy in the Post-Prostatectomy Setting , 2003, Technology in cancer research & treatment.

[23]  Purang Abolmaesumi,et al.  A real-time freehand ultrasound calibration system with automatic accuracy feedback and control. , 2009, Ultrasound in medicine & biology.

[24]  Purang Abolmaesumi,et al.  A Closed-Form Differential Formulation for Ultrasound Spatial Calibration , 2012, IPCAI.

[25]  D M Muratore,et al.  Beam calibration without a phantom for creating a 3-D freehand ultrasound system. , 2001, Ultrasound in medicine & biology.

[26]  N Pagoulatos,et al.  A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer. , 2001, Ultrasound in medicine & biology.

[27]  Laurence Mercier,et al.  A review of calibration techniques for freehand 3-D ultrasound systems. , 2005, Ultrasound in medicine & biology.

[28]  D. Louis Collins,et al.  Towards accurate, robust and practical ultrasound-CT registration of vertebrae for image-guided spine surgery , 2011, International Journal of Computer Assisted Radiology and Surgery.

[29]  Purang Abolmaesumi,et al.  A closed-form differential formulation for ultrasound spatial calibration: multi-wedge phantom. , 2014, Ultrasound in medicine & biology.

[30]  Thomas Langø,et al.  Probe calibration for freehand 3-D ultrasound. , 2003, Ultrasound in medicine & biology.

[31]  Hans-Peter Meinzer,et al.  Comparing calibration approaches for 3D ultrasound probes , 2008, International Journal of Computer Assisted Radiology and Surgery.

[32]  Daniel Rueckert,et al.  An Image Registration Approach to Automated Calibration for Freehand 3D Ultrasound , 2000, MICCAI.

[33]  G. Unsgaard,et al.  Surgical Resection of High-grade Gliomas in Eloquent Regions Guided by Blood Oxygenation Level Dependent Functional Magnetic Resonance Imaging, Diffusion Tensor Tractography, and Intraoperative Navigated 3D Ultrasound , 2009, Minimally invasive neurosurgery : MIN.

[34]  Russell H. Taylor,et al.  Information Processing in Computer-Assisted Interventions - Second International Conference, IPCAI 2011, Berlin, Germany, June 22, 2011. Proceedings , 2011, IPCAI.

[35]  Russell H. Taylor,et al.  A novel closed form solution for ultrasound calibration , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).

[36]  M. Genton Separable approximations of space‐time covariance matrices , 2007 .

[37]  Andrew H. Gee,et al.  Stradx: real-time acquisition and visualization of freehand three-dimensional ultrasound , 1999, Medical Image Anal..

[38]  Marco Caversaccio,et al.  On the Development and Comparative Evaluation of an Ultrasound B-Mode Probe Calibration Method , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[39]  Morgan Sangeux,et al.  Validation of 3-D freehand ultrasound for the determination of the hip joint centre. , 2010, Gait & posture.

[40]  Fernando Arambula Cosio,et al.  Computer assisted biopsy of breast tumors , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[41]  Takeo Kanade,et al.  Calibration Method for Determining the Physical Location of the Ultrasound Image Plane , 2001, MICCAI.

[42]  Rémi Souchon,et al.  Transrectal high-intensity focused ultrasound ablation of prostate cancer: effective treatment requiring accurate imaging. , 2007 .

[43]  Po-Wei Hsu,et al.  Real-time freehand 3D ultrasound calibration. , 2008, Ultrasound in medicine & biology.

[44]  Branislav Jaramaz,et al.  Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000 , 2000, Lecture Notes in Computer Science.

[45]  Purang Abolmaesumi,et al.  Single wall closed-form differential ultrasound calibration , 2012, Medical Imaging.

[46]  Jorge J. Moré,et al.  The Levenberg-Marquardt algo-rithm: Implementation and theory , 1977 .

[47]  Alfonso Mejia,et al.  Ultrasound-guided management of hand fractures. , 2008, Orthopedics.

[48]  Po-Wei Hsu,et al.  Freehand 3D Ultrasound Calibration: A Review , 2009 .

[49]  Frank Sauer,et al.  A Novel Phantom-Less Spatial and Temporal Ultrasound Calibration Method , 2005, MICCAI.