Enabling Flow-based Kinetic Off-rate Selections using a Microfluidic Enrichment Device (MFED).

Modern genomic sequencing efforts are identifying potential diagnostic and therapeutic targets more rapidly than existing methods can generate the peptide- and protein-based ligands required to study them. To address this problem, we have developed a Microfluidic Enrichment Device (MFED) enabling kinetic off-rate selection without the use of exogenous competitor. We tuned the conditions of the device (bed volume, flow rate, immobilized target) such that modest, readily achievable changes in flow rates favor formation or dissociation of target-ligand complexes based on affinity. Simple kinetic equations can be used to describe the behavior of ligand binding in the MFED and the kinetic rate constants observed agree with independent measurements. We demonstrate the utility of the MFED by showing a four-fold improvement in enrichment compared to standard selection. The MFED described here provides a route to simultaneously bias pools toward high-affinity ligands while reducing the demand for target-protein to less than a nanomole per selection.

[1]  David Fenyö,et al.  A toolbox of immunoprecipitation-grade monoclonal antibodies to human transcription factors , 2018, Nature Methods.

[2]  Noah Malmstadt,et al.  Modular, Discrete Micromixer Elements Fabricated by 3D Printing , 2017, Micromachines.

[3]  R. Roberts,et al.  RasIns: Genetically Encoded Intrabodies of Activated Ras Proteins. , 2017, Journal of molecular biology.

[4]  Lan Huong Lai,et al.  High-Throughput Measurement of Binding Kinetics by mRNA Display and Next-Generation Sequencing. , 2016, Angewandte Chemie.

[5]  R. Roberts,et al.  General, Label-Free Method for Determining K(d) and Ligand Concentration Simultaneously. , 2015, Analytical chemistry.

[6]  G. Chang,et al.  In vitro nanobody discovery for integral membrane protein targets , 2014, Scientific Reports.

[7]  R. Roberts,et al.  Robust, Quantitative Analysis of Proteins using Peptide Immunoreagents, in Vitro Translation, and an Ultrasensitive Acoustic Resonant Sensor , 2014, Analytical chemistry.

[8]  Bernardo L. Sabatini,et al.  Recombinant Probes for Visualizing Endogenous Synaptic Proteins in Living Neurons , 2013, Neuron.

[9]  R. Roberts,et al.  Antibody-mimetic ligand selected by mRNA display targets DC-SIGN for dendritic cell-directed antigen delivery. , 2013, ACS chemical biology.

[10]  Ren Sun,et al.  Single-round, multiplexed antibody mimetic design through mRNA display. , 2012, Angewandte Chemie.

[11]  Ren Sun,et al.  Rapid mRNA-display selection of an IL-6 inhibitor using continuous-flow magnetic separation. , 2011, Angewandte Chemie.

[12]  Yi Xiao,et al.  Improving aptamer selection efficiency through volume dilution, magnetic concentration, and continuous washing in microfluidic channels. , 2011, Analytical chemistry.

[13]  Seung Soo Oh,et al.  Generation of highly specific aptamers via micromagnetic selection. , 2009, Analytical chemistry.

[14]  H Tom Soh,et al.  Controlling the selection stringency of phage display using a microfluidic device. , 2009, Lab on a chip.

[15]  A. Heeger,et al.  Micromagnetic selection of aptamers in microfluidic channels , 2009, Proceedings of the National Academy of Sciences.

[16]  D. Baker,et al.  Realistic protein–protein association rates from a simple diffusional model neglecting long‐range interactions, free energy barriers, and landscape ruggedness , 2004, Protein science : a publication of the Protein Society.

[17]  K D Wittrup,et al.  Directed evolution of antibody fragments with monovalent femtomolar antigen-binding affinity. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[18]  K D Wittrup,et al.  Optimal Screening of Surface‐Displayed Polypeptide Libraries , 1998, Biotechnology progress.