Advanced methods for quantification of infarct size in mice using three-dimensional high-field late gadolinium enhancement MRI.

Conventional methods to quantify infarct size after myocardial infarction in mice are not ideal, requiring either tissue destruction for histology or relying on nondirect measurements such as wall motion. We therefore implemented a fast, high-resolution method to directly measure infarct size in vivo using three-dimensional (3D) late gadolinium enhancement MRI (3D-LGE). Myocardial T1 relaxation was quantified at 9.4 Tesla in five mice, and reproducibility was tested by repeat imaging after 5 days. In a separate set of healthy and infarcted mice (n = 8 of each), continuous T1 measurements were made following intravenous or intraperitoneal injection of a contrast agent (0.5 micromol/g gadolinium-diethylenetriamine pentaacetic acid). The time course of T1 contrast development between viable and nonviable myocardium was thereby determined, with optimal postinjection imaging windows and inversion times identified. Infarct sizes were quantified using 3D-LGE and compared with triphenyltetrazolium chloride histology on day 1 after infarction (n = 8). Baseline myocardial T1 was highly reproducible: the mean value was 952 +/- 41 ms. T1 contrast peaked earlier after intravenous injection than with intraperitoneal injection; however, contrast between viable and nonviable myocardium was comparable for both routes (P = 0.31), with adequate contrast remaining for at least 60 min postinjection. Excellent correlation was obtained between infarct sizes derived from 3D-LGE and histology (r = 0.91, P = 0.002), and Bland-Altman analysis indicated good agreement free from systematic bias. We have validated an improved 3D MRI method to noninvasively quantify infarct size in mice with unsurpassed spatial resolution and tissue contrast. This method is particularly suited to studies requiring early quantification of initial infarct size, for example, to measure damage before intervention with stem cells.

[1]  E. Fleck,et al.  Combined magnetic resonance coronary artery imaging, myocardial perfusion and late gadolinium enhancement in patients with suspected coronary artery disease , 2008, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[2]  Sashwati Roy,et al.  Characterization of the structural and functional changes in the myocardium following focal ischemia-reperfusion injury. , 2008, American journal of physiology. Heart and circulatory physiology.

[3]  Amy H Herlihy,et al.  Assessment of myocardial infarction in mice by Late Gadolinium Enhancement MR imaging using an inversion recovery pulse sequence at 9.4T , 2008, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[4]  S. Plein,et al.  Myocardial T1 mapping: Application to patients with acute and chronic myocardial infarction , 2007, Magnetic resonance in medicine.

[5]  Randall J. Lee,et al.  Myocardial infarct size measurement in the mouse chronic infarction model: comparison of area- and length-based approaches. , 2007, Journal of applied physiology.

[6]  K. Pitts,et al.  Washout of heme-containing proteins dramatically improves tetrazolium-based infarct staining. , 2007, Journal of pharmacological and toxicological methods.

[7]  Stefan Neubauer,et al.  The creatine kinase energy transport system in the failing mouse heart. , 2006, Journal of molecular and cellular cardiology.

[8]  T. R. Schmal,et al.  Mechanism of late gadolinium enhancement in patients with acute myocardial infarction. , 2007, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[9]  Udo Sechtem,et al.  Effects of time, dose, and inversion time for acute myocardial infarct size measurements based on magnetic resonance imaging-delayed contrast enhancement. , 2006, Journal of the American College of Cardiology.

[10]  Georg Ertl,et al.  Impaired resting perfusion in viable myocardium distal to chronic coronary stenosis in rats. , 2005, American journal of physiology. Heart and circulatory physiology.

[11]  Matthias Nahrendorf,et al.  In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging , 2005, Magnetic resonance in medicine.

[12]  Stefan Neubauer,et al.  Quantitative 3-Dimensional Echocardiography for Accurate and Rapid Cardiac Phenotype Characterization in Mice , 2004, Circulation.

[13]  David M Higgins,et al.  Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart , 2004, Magnetic resonance in medicine.

[14]  Stuart S Berr,et al.  Simultaneous Evaluation of Infarct Size and Cardiac Function in Intact Mice by Contrast-Enhanced Cardiac Magnetic Resonance Imaging Reveals Contractile Dysfunction in Noninfarcted Regions Early After Myocardial Infarction , 2004, Circulation.

[15]  S. Neubauer,et al.  Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields , 2004, Journal of magnetic resonance imaging : JMRI.

[16]  P. Cozzone,et al.  High‐resolution myocardial perfusion mapping in small animals in vivo by spin‐labeling gradient‐echo imaging , 2004, Magnetic resonance in medicine.

[17]  M. Robson,et al.  Influence of contrast agent dose and image acquisition timing on the quantitative determination of nonviable myocardial tissue using delayed contrast-enhanced magnetic resonance imaging. , 2004, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[18]  Kieran Clarke,et al.  Fast, high‐resolution in vivo cine magnetic resonance imaging in normal and failing mouse hearts on a vertical 11.7 T system , 2003, Journal of magnetic resonance imaging : JMRI.

[19]  J. Oshinski,et al.  Imaging Time After Gd-DTPA Injection Is Critical in Using Delayed Enhancement to Determine Infarct Size Accurately With Magnetic Resonance Imaging , 2001, Circulation.

[20]  O. Simonetti,et al.  Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function. , 1999, Circulation.

[21]  A. Haase,et al.  In Vivo quantitative mapping of cardiac perfusion in rats using a noninvasive MR spin‐labeling method , 1998, Journal of magnetic resonance imaging : JMRI.

[22]  G. J. Crystal,et al.  Coronary Vasodilation by Isoflurane: Abrupt Versus Gradual Administration , 1995, Anesthesiology.

[23]  G. J. Crystal,et al.  Coronary vasodilation by isoflurane. Abrupt versus gradual administration. , 1994 .

[24]  R Deichmann,et al.  Quantification of T1 values by SNAPSHOT-FLASH NMR imaging , 1992 .