Condensation Heat Transfer Characteristics of Moist Air Outside Hydrophilic and Super-hydrophobic 3D Pin Fin Tube

Three dimensional pin fin tube is an effective heat transfer element. It has been widely used in industry process. However, condensation heat transfer characteristic of moist air outside it has not been experimentally studied. The wettability of tube surface has an important effect on this process. In this study, experiments were carried out, in which moist air condensing outside three dimensional pin fin tube with different wettability. Smooth tube is also tested to make comparison. Effects of steam mole fraction, moist air temperature, and wall subcooling are analysed in detail. Super-hydrophobic surface is obtained using oxidation and self-assembling monolayer method. The results show that heat transfer coefficient increases with the increase of steam mole fraction, wall subcooling and the decrease of moist air temperature. Heat transfer coefficient ranges from 55 to 2,035 W/mK within the study of this paper, and hydrophilic three dimensional finned tube can achieve 2 times heat transfer coefficient compared with smooth tube and superhydrophobic three dimensional pin fin tube.

[1]  Jinliang Xu,et al.  Dropwise condensation heat transfer on superhydrophilic-hydrophobic network hybrid surface , 2019, International Journal of Heat and Mass Transfer.

[2]  Min Cheng,et al.  Influence of geometric parameters on the gas-side heat transfer and pressure drop characteristics of three-dimensional finned tube , 2019, International Journal of Heat and Mass Transfer.

[3]  Min Cheng,et al.  Experimental investigation on the air-side flow and heat transfer characteristics of 3-D finned tube bundle , 2019, International Journal of Heat and Mass Transfer.

[4]  M. Corradini,et al.  CFD modeling of filmwise steam condensation with noncondensable gas with modified boundary condition , 2018, International Journal of Heat and Mass Transfer.

[5]  Shixue Wang,et al.  Effects of extended surface and surface gold plating on condensation characteristics of steam with large amount of CO2 , 2018 .

[6]  Tailian Chen,et al.  Enhancement in heat transfer during condensation of an HFO refrigerant on a horizontal tube with 3D fins , 2018 .

[7]  Xiaomin Wu,et al.  Approximate equations for film condensation in the presence of non-condensable gases , 2017 .

[8]  Zhongning Sun,et al.  An experimental investigation of pure steam and steam–air mixtures condensation outside a vertical pin-fin tube , 2015 .

[9]  H. Ali,et al.  Free convection condensation of steam on horizontal wire wrapped tubes: Effect of wire thermal conductivity, pitch and diameter , 2015 .

[10]  D. Niu,et al.  Experimental investigation of condensation heat transfer on hybrid wettability finned tube with large amount of noncondensable gas , 2015 .

[11]  Shixue Wang,et al.  Experimental investigation of steam condensation with high concentration CO2 on a horizontal tube , 2013 .

[12]  W. Tao,et al.  Experimental and numerical studies on actual flue gas condensation heat transfer in a left–right symmetric internally finned tube , 2013 .

[13]  H. Ali,et al.  Condensation of ethylene glycol on pin-fin tubes: Effect of circumferential pin spacing and thickness , 2012 .

[14]  Adrian Briggs,et al.  Condensation From Pure Steam and Steam–Air Mixtures on Integral-Fin Tubes in a Bank , 2005 .

[15]  M. Osakabe,et al.  Condensation heat transfer of actual flue gas on horizontal tubes , 1999 .

[16]  D. Othmer The Condensation of Steam , 1929 .