Micro analysis system for pH and protease activities with an integrated sample injection mechanism.

[1]  M. Laskowski [3] Trypsinogen and trypsin , 1955 .

[2]  Hans Ulrich Bergmeyer,et al.  Methods of Enzymatic Analysis , 2019 .

[3]  S. Colowick,et al.  Methods in Enzymology , Vol , 1966 .

[4]  E. Shaw,et al.  [2] Titration of trypsin, plasmin, and thrombin with p-nitrophenyl p′-guanidinobenzoate HCl☆ , 1970 .

[5]  K. A. Walsh,et al.  [4] Trypsinogens and trypsins of various species , 1970 .

[6]  G. Moores,et al.  Conductimetry in enzyme studies. , 1972, European journal of biochemistry.

[7]  Gerald D Fasman Handbook of Biochemistry , 1976 .

[8]  C. Walsh,et al.  Enzymatic Reaction Mechanisms , 1978 .

[9]  M. Jozefowicz,et al.  Electrochemical activity determination of trypsin-like enzymes. III. Application to the assay of antithrombin III in aqueous solutions, human plasma and whole blood. , 1980, Thrombosis research.

[10]  M. Jozefowicz,et al.  The electrochemical activity determination of trypsin-like enzymes. I - Trypsin. , 1980, Thrombosis research.

[11]  G. Beni,et al.  Dynamics of electrowetting displays , 1981 .

[12]  M. Hitchman,et al.  Evaluation of iridium oxide electrodes formed by potential cycling as pH probes. , 1988, The Analyst.

[13]  Shuichi Shoji,et al.  Prototype miniature blood gas analyser fabricated on a silicon wafer , 1988 .

[14]  Wouter Olthuis,et al.  A dipstick sensor for coulometric acid-base titrations , 1989 .

[15]  Jens Anders Branebjerg,et al.  Microfluidics-a review , 1993 .

[16]  Masayoshi Esashi,et al.  Microflow devices and systems , 1994 .

[17]  Jan H. J. Fluitman,et al.  Towards integrated microliquid handling systems , 1994 .

[18]  W. Hoffmann,et al.  Integrated microanalytical system with electrochemical detection , 1996 .

[19]  G. Kovacs Micromachined Transducers Sourcebook , 1998 .

[20]  F. Rowell,et al.  Use of substrate coated electrodes and AC impedance spectroscopy for the detection of enzyme activity , 1998 .

[21]  R. Venkatesh,et al.  Modulation of stability properties of bovine trypsin after in vitro structural changes with a variety of chemical modifiers. , 1998, Protein engineering.

[22]  Isao Karube,et al.  Microfabricated Liquid Junction Ag/AgCl Reference Electrode and Its Application to a One-Chip Potentiometric Sensor , 1999 .

[23]  G. Iddan,et al.  Wireless capsule endoscopy , 2003, Gut.

[24]  Y. Hsieh,et al.  Mechanism and characteristics of protein release from lactitol-based cross-linked hydrogel. , 2000, Journal of agricultural and food chemistry.

[25]  Hiroaki Suzuki,et al.  Thin-Film Ag/AgCl Structure and Operational Modes to Realize Long-Term Storage , 2001 .

[26]  A. Murray,et al.  Toward a miniature wireless integrated multisensor microsystem for industrial and biomedical applications , 2002 .

[27]  E. Forzani,et al.  Indirect determination of pepsin activity in human seric protein samples by polyphenol oxidase electrodes , 2002 .

[28]  M. Meyerhoff,et al.  Electrochemical assay of protease activities based on polycation/polyanion complex as substrate and polyion sensitive membrane electrode detection. , 2003, Biosensors & bioelectronics.

[29]  Hiroaki Suzuki,et al.  Microfluidic transport based on direct electrowetting , 2004 .

[30]  M. Loughran,et al.  Microanalysis system for pO/sub 2/, pCO/sub 2/, and pH constructed with stacked modules , 2005 .