New method for noninvasive measurement of utility harmonic impedance

The new, noninvasive method of measurement for power system harmonic impedance is presented in the paper. The method is based on the observation of variations of voltage and current harmonics caused by natural load variability. The novelty of the method lays in a way the method rejects segments of data containing insufficient or false information about the identified power system. Segment selection/rejection uses logical conditions applied to RMS values of measured voltage and current. Harmonic impedance of the power grid is then calculated using modified power spectral method. The method was validated in a field test conducted at 30 kV feeder bus of HV/MV substation. Details of the experiment and the results are discussed the paper. Obtained results confirm that the method copes with temporal, band-limited excitation as well as with deep, sudden changes of utility background voltage.

[1]  Paulo F. Ribeiro,et al.  Guide for assessing the network harmonic impedance , 1997 .

[2]  M.R. Iravani,et al.  Measurement of harmonics/inter-harmonics of time-varying frequencies , 2005, IEEE Transactions on Power Delivery.

[3]  P. Welch The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms , 1967 .

[4]  A. Testa,et al.  A New Method for Statistical Assessment of the System Harmonic Impedance and of the Background Voltage Distortion , 2006, 2006 International Conference on Probabilistic Methods Applied to Power Systems.

[5]  G. Moreau,et al.  Measurement system for harmonic impedance of the network and validation steps , 2003, CIGRE/IEEE PES International Symposium Quality and Security of Electric Power Delivery Systems, 2003. CIGRE/PES 2003..

[6]  Alan V. Oppenheim,et al.  Discrete-time Signal Processing. Vol.2 , 2001 .

[7]  A. Ferrero,et al.  A low-cost frequency multiplier for synchronous sampling of periodic signals , 1991, [1991] Conference Record. IEEE Instrumentation and Measurement Technology Conference.

[8]  Patricio G. Donato,et al.  FPGA design of a variable sampling period PLL with a Digital Notch Filter for distorted grids , 2011, 2011 Argentine School of Micro-Nanoelectronics, Technology and Applications.

[9]  Honggeng Yang,et al.  Assessing Utility Harmonic Impedance Based on the Covariance Characteristic of Random Vectors , 2010, IEEE Transactions on Power Delivery.

[10]  Mark Sumner,et al.  A technique for power supply harmonic impedance estimation using a controlled voltage disturbance , 2002 .

[11]  Salvatore Nuccio,et al.  Comparison of Nonactive Powers for the Detection of Dominant Harmonic Sources in Power Systems , 2008, IEEE Transactions on Instrumentation and Measurement.

[12]  Hualin Gong,et al.  A New Assessment Method of Customer Harmonic Emission Level , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[13]  R. Gretsch,et al.  System impedances and background noise in the frequency range 2 kHz to 9 kHz , 2007 .

[14]  Wilsun Xu,et al.  Measurement of Harmonic Sources in Three-Wire Single-Phase Supply Systems , 2007 .

[15]  M. Molinas,et al.  Constant power loads in AC distribution systems: An investigation of stability , 2008, 2008 IEEE International Symposium on Industrial Electronics.

[16]  R. B. McManis,et al.  Frequency Domain Techniques for Modeling Distribution or Transmission Networks Using Capacitor Switching Induced Transients , 1989, IEEE Power Engineering Review.

[17]  W. Xu,et al.  Measurement of Network Harmonic Impedences: Practical Implementation Issues and Their Solutions , 2001, IEEE Power Engineering Review.

[18]  D. Borkowski On-line instantaneous frequency estimation and voltage/current coherent resampling method , 2005 .

[19]  Leszek S. Czarnecki,et al.  On-line measurement of equivalent parameters of distribution system and its load for harmonic frequencies , 1995, Proceedings of 1995 IEEE Instrumentation and Measurement Technology Conference - IMTC '95.

[20]  Salvatore Nuccio,et al.  A Phase-Locked Loop for the Synchronization of Power Quality Instruments in the Presence of Stationary and Transient Disturbances , 2007, IEEE Transactions on Instrumentation and Measurement.

[21]  Wilsun Xu,et al.  An Investigation on the Validity of Power-Direction Method for Harmonic Source Determination , 2001 .

[22]  A. Bień,et al.  Computation of the network harmonic impedance with Chirp-Z transform , 2009 .

[23]  D. Borkowski,et al.  Improvement of Accuracy of Power System Spectral Analysis by Coherent Resampling , 2009, IEEE Transactions on Power Delivery.

[24]  A. S. Morched,et al.  Identification and Modelling of Load Characteristics at High Frequencies , 1987, IEEE Transactions on Power Systems.

[25]  D. Borkowski,et al.  Estimation of power system parameters based on load variance observations - laboratory studies , 2007, 2007 9th International Conference on Electrical Power Quality and Utilisation.