Study of a wire-driven leg rehabilitation system

In this paper, we describe human subject experiments of a multiple-degree-of-freedom (DOF) leg rehabilitation system that we have proposed. The characteristic of the proposed system is employment of a parallel wire mechanism. The rehabilitation devices using a parallel wire mechanism are expected to have the advantages such as system safety and human-friendliness. We have built and are testing a 4-DOF experimental system. The target motions of the experimental system are hip joint flexion/extension, hip joint abduction/adduction, hip joint external/internal rotation, and knee joint flexion/extension. The experimental results showed that the experimental system can carry out 4-DOF motions with different patient postures. Also the results of subjective evaluation showed that the proposed system makes the subjects feel less constrained.

[1]  N. Hogan,et al.  Robot-aided neurorehabilitation. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[2]  Tatsuo Arai,et al.  Design of an upper limb motion assist system with parallel mechanism , 1995, Proceedings of 1995 IEEE International Conference on Robotics and Automation.

[3]  A. Ming,et al.  Study on multiple degree-of-freedom positioning mechanism using wires. I: Concept, design and control , 1994 .

[4]  Hideo Hanafusa,et al.  Development of a power assistive device for self-supported transfer motion , 2002, IEEE/RSJ International Conference on Intelligent Robots and Systems.

[5]  Keiko Homma,et al.  A wire-driven leg rehabilitation system: development of a 4-DOF experimental system , 2003, Proceedings 2003 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM 2003).

[6]  Tatsuo Arai,et al.  An upper limb motion assist system: experiments with arm models , 1998, Proceedings. 1998 IEEE/RSJ International Conference on Intelligent Robots and Systems. Innovations in Theory, Practice and Applications (Cat. No.98CH36190).

[7]  R. Salter,et al.  The biological effect of continuous passive motion on the healing of full-thickness defects in articular cartilage. An experimental investigation in the rabbit. , 1980, The Journal of bone and joint surgery. American volume.

[8]  Keiko Homma,et al.  Development of Leg Rehabilitation Assistance , 2002, J. Robotics Mechatronics.

[9]  O. Fukuda,et al.  Study of a wire-driven leg rehabilitation system , 2002, IEEE/RSJ International Conference on Intelligent Robots and Systems.

[10]  Shoshiro Hatakeyama,et al.  Development of Powered Upper-Limb Orthoses , 1993 .