On-line transient stability screening of 14,000-bus models using TEPCO-BCU: Evaluations and methods

PJM Interconnection has successfully designed and implemented a Transient Stability Analysis & Control (TSA&C) system. This is the first on-line transient stability analysis ever performed in the control center of a large power network. TEPCO-BCU was selected as a leading fast screening tool to improve the performance of PJM's TSA system. This paper will present an evaluation of TEPCO-BCU in a real time environment as a transient stability analysis screening tool. This evaluation represents the largest practical application of the theory of a stability region in terms of the system size (14,000-bus), the number of contingencies (a total of 5,293,691 contingencies), and over a wide range of operating conditions. This extensive numerical study reveals that TEPCO-BCU is an effective tool for performing on-line dynamic contingency screening of large-scale power systems‥

[1]  Lei Wang,et al.  Implementation of online security assessment , 2006, IEEE Power and Energy Magazine.

[2]  Felix F. Wu,et al.  A BCU method for direct analysis of power system transient stability , 1994 .

[3]  Chia-Chi Chu,et al.  Direct stability analysis of electric power systems using energy functions: theory, applications, and perspective , 1995, Proc. IEEE.

[4]  Hua Li,et al.  Development of BCU classifiers for on-line dynamic contingency screening of electric power systems , 1999 .

[5]  Hsiao-Dong Chiang,et al.  Power System On‐Line Transient Stability Assessment , 2007 .

[6]  Hsiao-Dong Chiang,et al.  Theoretical foundation of the BCU method for direct stability analysis of network-reduction power system. Models with small transfer conductances , 1995 .

[7]  E. Vaahedi,et al.  A general purpose method for on-line dynamic security assessment , 1998 .

[8]  Kwok W. Cheung,et al.  BC Hydro's on-line transient stability assessment (TSA) model development, analysis and post-processing , 1995 .

[9]  W. Marsden I and J , 2012 .

[10]  Hsiao-Dong Chiang The BCU Method for Direct Stability Analysis of Electric Power Systems: Theory and Applications , 1995 .

[11]  T. W. Gedra,et al.  On transmission congestion and pricing , 1999 .

[12]  Kaoru Koyanagi,et al.  BCU-guided time-domain method for energy margin calculation to improve BCU-DSA system , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[13]  Vijay Vittal,et al.  An on-line contingency filtering scheme for dynamic security assessment , 1997 .

[14]  Anjan Bose,et al.  On-line power system security analysis , 1992, Proc. IEEE.

[15]  A. Y. Chang,et al.  Enhanced "Second Kick" methods for on-line dynamic security assessment , 1996 .

[16]  Jianzhong Tong,et al.  A sensitivity-based BCU method for fast derivation of stability limits in electric power systems , 1993 .

[17]  Pravin Varaiya,et al.  Foundations of direct methods for power system transient stability analysis , 1987 .

[18]  M. Pavella,et al.  A unified approach to transient stability contingency filtering, ranking and assessment , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[19]  R. Fischl,et al.  Power system security assessment , 1984, IEEE Conference on Decision and Control.

[20]  Charles Concordia,et al.  Power System Stability , 1985, IEEE Power Engineering Review.

[21]  Jianzhong Tong,et al.  Transient Stability Evaluation of a 12,000-bus Power System Data Using TEPCO-BCU , 2005 .

[22]  Hsiao-Dong Chiang,et al.  Design and Implementation of on‐line dynamic security assessment , 2009 .