Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation †

Electrical Impedance Tomography (EIT) is a non-invasive detection method to image the conductivity changes inside an observation region by using the electrical measurements at the boundary of this region. In some applications of EIT, the observation domain is infinite and is only accessible from one side, which leads to the so-called open EIT (OEIT) problem. Compared with conventional EIT problems, the observation region in OEIT can only be measured from limited projection directions, which makes high resolution imaging much more challenging. To improve the imaging quality of OEIT, a focusing sensor design strategy is proposed based on shape conformal theory. The conformal bijection is used to map a standard EIT sensor defined at a unit circle to a focusing OEIT sensor defined at an upper half plane. A series of numerical and experimental testes are conducted. Compared with the traditional sensor structure, the proposed focusing sensor has higher spatial resolution at the near-electrode region and is good at distinguishing multi-inclusions which are close to each other.

[1]  J. G. Webster,et al.  Finite-element method in electrical impedance tomography , 1994, Medical and Biological Engineering and Computing.

[2]  Hui Xiong,et al.  Evaluation of measurement and stimulation patterns in open electrical impedance tomography with scanning electrode , 2015, Medical & Biological Engineering & Computing.

[3]  Robert Banasiak,et al.  3D-Printed Multilayer Sensor Structure for Electrical Capacitance Tomography , 2019, Sensors.

[4]  Manuchehr Soleimani,et al.  Inclusion boundary reconstruction and sensitivity analysis in electrical impedance tomography , 2018 .

[5]  J. Harris,et al.  Control of the height of Schottky barriers on MBE GaAs , 1983 .

[6]  Jari P. Kaipio,et al.  Tikhonov regularization and prior information in electrical impedance tomography , 1998, IEEE Transactions on Medical Imaging.

[7]  Cherepenin V A,et al.  An electrical impedance tomography system for gynecological application GIT with a tiny electrode array. , 2012, Physiological measurement.

[8]  Laurent Pambaguian,et al.  Damage identification in carbon fiber reinforced polymer plates using electrical resistance tomography mapping , 2013 .

[9]  Manuchehr Soleimani,et al.  Planar Array Capacitive Imaging Sensor Design Optimization , 2017, IEEE Sensors Journal.

[10]  Manuchehr Soleimani,et al.  Selected Papers from the 9th World Congress on Industrial Process Tomography , 2019, Sensors.

[11]  Masahiro Takei,et al.  Application of Process Tomography to Multiphase Flow Measurement in Industrial and Biomedical Fields: A Review , 2017, IEEE Sensors Journal.

[12]  Michael Pidcock,et al.  A three-dimensional image reconstruction algorithm for electrical impedance tomography using planar electrode arrays , 2017 .

[13]  Brian H. Brown,et al.  Imaging spatial distributions of resistivity using applied potential tomography , 1983 .

[14]  Dong Liu,et al.  Estimation of conductivity changes in a region of interest with electrical impedance tomography , 2014, 1403.6587.

[15]  Feng Dong,et al.  A Transformation-Domain Image Reconstruction Method for Open Electrical Impedance Tomography Based on Conformal Mapping , 2019, IEEE Sensors Journal.

[16]  Ines Fischer,et al.  Dictionary Of Conformal Representations , 2016 .

[17]  Hao Wang,et al.  Development of a Portable Electrical Impedance Tomography System for Biomedical Applications , 2018, IEEE Sensors Journal.

[18]  J.P. Kaipio,et al.  Three-dimensional electrical impedance tomography based on the complete electrode model , 1999, IEEE Transactions on Biomedical Engineering.

[19]  Lihui Peng,et al.  Image reconstruction algorithms for electrical capacitance tomography , 2003 .

[20]  Kirill Y Aristovich,et al.  A method for reconstructing tomographic images of evoked neural activity with electrical impedance tomography using intracranial planar arrays , 2014, Physiological measurement.

[21]  K D Paulsen,et al.  Electrical impedance tomography reconstruction for three-dimensional imaging of the prostate , 2010, Physiological measurement.

[22]  Feng Dong,et al.  A Wideband Electrical Impedance Tomography System Based on Sensitive Bioimpedance Spectrum Bandwidth , 2020, IEEE Transactions on Instrumentation and Measurement.

[23]  Guanghui Liang,et al.  A Robust Inclusion Boundary Reconstructor for Electrical Impedance Tomography With Geometric Constraints , 2019, IEEE Transactions on Instrumentation and Measurement.

[24]  Ryan J. Halter,et al.  A Novel Regularization Technique for Microendoscopic Electrical Impedance Tomography , 2016, IEEE Transactions on Medical Imaging.

[25]  Kai Sun,et al.  A Statistical Shape-Constrained Reconstruction Framework for Electrical Impedance Tomography , 2019, IEEE Transactions on Medical Imaging.

[26]  A. V. Korjenevsky,et al.  An electrical impedance tomography system for gynecological application GIT with a tiny electrode array , 2012 .

[27]  John E. McFee,et al.  Electrical Impedance Tomographic Imaging of Buried Landmines , 2006, IEEE Transactions on Geoscience and Remote Sensing.

[28]  Mohammad Pour-Ghaz,et al.  Electrical impedance tomography-based sensing skin for quantitative imaging of damage in concrete , 2014 .

[29]  J C Newell,et al.  Reconstruction of conductivity changes due to ventilation and perfusion from EIT data collected on a rectangular electrode array. , 2001, Physiological measurement.

[30]  Andy Adler,et al.  In Vivo Impedance Imaging With Total Variation Regularization , 2010, IEEE Transactions on Medical Imaging.

[31]  Dong Liu,et al.  A Parametric Level Set Method for Electrical Impedance Tomography , 2018, IEEE Transactions on Medical Imaging.

[32]  William R B Lionheart,et al.  Uses and abuses of EIDORS: an extensible software base for EIT , 2006, Physiological measurement.

[33]  B. Brandstatter,et al.  Jacobian calculation for electrical impedance tomography based on the reciprocity principle , 2003 .

[34]  William R B Lionheart,et al.  GREIT: a unified approach to 2D linear EIT reconstruction of lung images , 2009, Physiological measurement.

[35]  David S. Holder,et al.  Electrical Impedance Tomography : Methods, History and Applications , 2004 .

[36]  Ahmed M. Youssef,et al.  Sinkhole detection using electrical resistivity tomography in Saudi Arabia , 2012 .