Robust kidney stone tracking for a non-invasive ultrasound theragnostic system-Servoing performance and safety enhancement-

We propose a non-invasive ultrasound theragnostic system that tracks movement in an affected area (kidney stones, in the present study) by irradiating the area with high-intensity focused ultrasound (HIFU). In the present paper, the concept behind a novel medical support system that integrates therapy and diagnostics (theragnostics) is illustrated. The required functions for the proposed system are discussed and an overview of the constructed system configuration is illustrated. The problems associated with kidney stone motion tracking by ultrasonography are described. In order to overcome these problems, we consider two approaches. The first approach is to minimize the servoing error so as to enhance both the efficiency of the therapy and the safety of the patient. The second approach is to reduce the effect of the servoing error. With respect to the first approach, we propose a robust detection method of the stone position based on shape information. With respect to the second approach, we propose a solution for controlling the HIFU irradiation power in accordance with the servoing error, primarily in order to enhance the safety of the patient.

[1]  Mathieu Pernot,et al.  3-D real-time motion correction in high-intensity focused ultrasound therapy. , 2004, Ultrasound in medicine & biology.

[2]  Wen-Hong Zhu,et al.  Image-guided control of a robot for medical ultrasound , 2002, IEEE Trans. Robotics Autom..

[3]  Wen-zhi Chen,et al.  Pathological changes in human malignant carcinoma treated with high-intensity focused ultrasound. , 2001, Ultrasound in medicine & biology.

[4]  Mamoru Mitsuishi,et al.  A control framework for the non-invasive ultrasound theragnostic system , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[5]  A. E. Miller,et al.  A NEW METHOD FOR THE GENERATION AND USE OF FOCUSED ULTRASOUND IN EXPERIMENTAL BIOLOGY , 1942, The Journal of general physiology.

[6]  Gregory D. Hager,et al.  Full Motion Tracking in Ultrasound Using Image Speckle Information and Visual Servoing , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[7]  Y Nakamura,et al.  Robotic stabilization that assists cardiac surgery on beating hearts. , 2001, Studies in health technology and informatics.

[8]  Shin Yoshizawa,et al.  Cloud cavitation control for lithotripsy using high intensity focused ultrasound. , 2006, Ultrasound in medicine & biology.

[9]  Ronald L. Graham,et al.  An Efficient Algorithm for Determining the Convex Hull of a Finite Planar Set , 1972, Inf. Process. Lett..

[10]  D. Cranston,et al.  High intensity focused ultrasound: surgery of the future? , 2003, The British journal of radiology.

[11]  Mamoru Mitsuishi,et al.  A Framework of the Non-invasive Ultrasound Theragnostic System , 2008, MIAR.

[12]  Michael R. Bailey,et al.  Ultracal-30 gypsum artificial stones for research on the mechanisms of stone breakage in shock wave lithotripsy , 2005, Urological Research.

[13]  Yoshihiko Nakamura,et al.  Heartbeat synchronization for robotic cardiac surgery , 2001, Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164).

[14]  Nitish V. Thakor,et al.  Surgical Motion Adaptive Robotic Technology (S.M.A.R.T): Taking the Motion out of Physiological Motion , 2001, MICCAI.

[15]  F. Gleeson,et al.  High-intensity focused ultrasound for the treatment of liver tumours. , 2004, Ultrasonics.

[16]  Luc Soler,et al.  Beating heart tracking in robotic surgery using 500 Hz visual servoing, model predictive control and an adaptive observer , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.