Normal and Shear Force Measurement Using a Flexible Polymer Tactile Sensor With Embedded Multiple Capacitors

In this paper, we report a new flexible capacitive tactile sensor array with the capability of measuring both normal and shear force distribution using polydimethylsiloxane (PDMS) as a base material. A tactile cell consists of two thick PDMS layers with embedded electrodes, an air gap, and a pillar structure. The pillar structure is formed at the center of each tactile cell between the air gap under a large bump. There are four capacitors in a cell to decompose the contact force into normal and shear components. Four capacitors are arranged in a square form. If a normal force is applied on the bump, the PDMS layer on the pillar structure is compressed, and the air gap between the top and bottom electrodes decreases, resulting in the increase in all four capacitances. If a shear force is applied, a torque is induced around the pillar. Therefore, the capacitance of the two capacitors increases, whereas that of the other two decreases. The bump and the pillar structure play a critical role to generate a torque for shear force measurement. The sensor has been realized in an 8 x 8 array of unit sensors, and each unit sensor responds to normal and shear stresses in all three axes, respectively. Measurement of a single sensor shows that the full-scale range of detectable force is about 10 mN, which corresponds to 131 kPa in three directions. The sensitivities of a cell measured with a current setup are 2.5%/mN, 3.0%/mN, and 2.9 %/mN for the x-, y-, and z-directions, respectively. Normal and shear force images are also captured from a 4 x 4 array of the fabricated sensor. Distinctive characteristic patterns appear when a shear force is applied to the sensor.

[1]  J. Spronck,et al.  A capacitive tactile sensor for shear and normal force measurements , 1992 .

[2]  Robert D. Howe,et al.  Remote palpation technology , 1995 .

[3]  Joost Conrad Lötters,et al.  Polydimethylsiloxane as an elastic material applied in a capacitive accelerometer , 1996 .

[4]  S. Middelhoek,et al.  Silicon three-axial tactile sensor , 1996 .

[5]  B. J. Kane,et al.  A traction stress sensor array for use in high-resolution robotic tactile imaging , 2000, Journal of Microelectromechanical Systems.

[6]  S. Quake,et al.  Monolithic microfabricated valves and pumps by multilayer soft lithography. , 2000, Science.

[7]  Chang Liu,et al.  Development of polyimide flex-ible tactile sensor skin , 2003 .

[8]  V Casey,et al.  Elastomer rubbers as deflection elements in pressure sensors: investigation of properties using a custom designed programmable elastomer test rig , 2003 .

[9]  E. Hwang,et al.  A Polymer-Based Flexible Tactile Sensor for Normal and Shear Load Detection , 2006, 19th IEEE International Conference on Micro Electro Mechanical Systems.

[10]  Hyung-Kew Lee,et al.  A Flexible Polymer Tactile Sensor: Fabrication and Modular Expandability for Large Area Deployment , 2006, Journal of Microelectromechanical Systems.

[11]  K.R. Lee,et al.  3-Axes Flexible Tactile Sensor Fabricated by Si Micromachining and Packaging Technology , 2006, 19th IEEE International Conference on Micro Electro Mechanical Systems.

[12]  Euisik Yoon,et al.  Polymer tactile sensing array with a unit cell of multiple capacitors for three-axis contact force image construction , 2007, 2007 IEEE 20th International Conference on Micro Electro Mechanical Systems (MEMS).