Characterization of scatter radiation in cone beam CT mammography

Cone beam CT mammography (CBCTM) is an emerging breast imaging technology and is currently under intensive investigation [1-3]. One of the major challenges in CBCTM is to understand the characteristics of scatter radiation and to find ways to reduce or correct its degrading effects. Since the breast shape, geometry and image formation process are significantly different from conventional mammography, all system components and parameters such as target/filter combination, kVp range, source to image distance, detector design etc. should be examined and optimized. In optimizing CBCTM systems, it is important to have knowledge of how different imaging parameters affect the recorded scatter within the image. In this study, a GEANT4 based Monte Carlo simulation package (GATE) was used to investigate the scatter magnitude and its’ distribution in CBCTM. The influences of different air gaps, kVp settings, breast sizes and breast composition on the scatter primary ratio (SPR) and scatter profiles were examined. In general, the scatter to primary ratio (SPR) is strongly dependent on the breast size and air gap, and is only moderately dependent on the kVp setting and breast composition. These results may be used for optimization of CBCTM systems, as well as for developing scatter correction methods.

[1]  J. Boone,et al.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV. , 1997, Medical physics.

[2]  Gary H. Glover,et al.  Compton scatter effects in CT reconstructions , 1982 .

[3]  C Lartizien,et al.  GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.

[4]  Tao Wu,et al.  A comparison of reconstruction algorithms for breast tomosynthesis. , 2004, Medical physics.

[5]  D. Jaffray,et al.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter. , 2001, Medical physics.

[6]  D. Kopans,et al.  Tomographic mammography using a limited number of low-dose cone-beam projection images. , 2003, Medical physics.

[7]  J. S. Laughlin,et al.  Absorbed radiation dose in mammography. , 1979, Radiology.

[8]  J. Boone,et al.  Dedicated breast CT: radiation dose and image quality evaluation. , 2001, Radiology.

[9]  D. Kopans,et al.  Digital tomosynthesis in breast imaging. , 1997, Radiology.

[10]  Michael Sandborg,et al.  Simulation of scatter in cone beam CT: effects on projection image quality , 2003, SPIE Medical Imaging.

[11]  Srinivasan Vedantham,et al.  Investigation of optimal kVp settings for CT mammography using a flat-panel imager , 2002, SPIE Medical Imaging.

[12]  S. Feig,et al.  Decreased breast cancer mortality through mammographic screening: results of clinical trials. , 1988, Radiology.

[13]  D. Jaffray,et al.  Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography). , 2000, Medical physics.

[14]  Biao Chen,et al.  Cone-beam volume CT breast imaging: feasibility study. , 2002, Medical physics.

[15]  P M Joseph,et al.  The effects of scatter in x-ray computed tomography. , 1982, Medical physics.

[16]  S. Feig,et al.  Estimation of currently attainable benefit from mammographic screening of women aged 40‐49 years , 1995, Cancer.

[17]  John M. Boone,et al.  Progress in the development of a dedicated breast CT scanner , 2004, SPIE Medical Imaging.

[18]  Ruola Ning,et al.  X-ray scatter correction algorithm for cone beam CT imaging. , 2004, Medical physics.