Picosescond fluorescence lifetime standards for frequency- and time-domain fluorescence

We characterized a series of dimethylamino-stilbene derivatives as standards for time-domain and frequency-domain lifetime measurements. The substances have reasonable quantum yields, are soluble in solvents available with a high purity, and do not show significant sensitivity to oxygen quenching. All the fluorophores displayed single exponential intensity decays, as characterized by frequency-domain measurements to 10 GHz. The decay times vary from 880 to 57 ps, depending on structure, solvent, and temperature, which is a useful range for modern picosecond time-domain or gigahertz frequency-domain instruments. These fluorophores may be used either to test an instrument or as reference compounds to eliminate color effects. We also characterized two-fluorophore mixtures, with the decay times spaced twofold (150 and 300 ps), with varying proportions. These mixtures are useful for testing the resolution of other time- and frequency-domain instrumentation. The excitation wavelength ranges from 260 to 430 nm, and the emission from 350 to 550 nm. The decay times are independent of the excitation and emission wavelengths.

[1]  A. Grinvald The use of standards in the analysis of fluorescence decay data. , 1976, Analytical biochemistry.

[2]  S. Meech,et al.  Complex fluorescence decay of quinine bisulphate in aqueous sulphuric acid solution , 1982 .

[3]  D. Barrow,et al.  The use of isochronal reference standards in phase and modulation fluorescence lifetime measurements. , 1983, Journal of biochemical and biophysical methods.

[4]  J. Lakowicz,et al.  A 4-GHz frequency-domain fluorometer with internal microchannel plate photomultiplier cross-correlation. , 1991, Analytical biochemistry.

[5]  H. Bredereck,et al.  Orthoamide, XXV. Synthese und Reaktionen von [α‐(Dimethylaminomethylen)‐benzyl]triphenylphosphonium‐Salzen , 1973 .

[6]  E Gratton,et al.  Resolution of mixtures of fluorophores using variable-frequency phase and modulation data. , 1984, Biophysical journal.

[7]  R. Alfano,et al.  THE USE OF SHORT LIVED FLUORESCENT DYES TO CORRECT FOR ARTIFACTS IN THE MEASUREMENTS OF FLUORESCENCE LIFETIMES , 1985, Photochemistry and photobiology.

[8]  G. K. Rollefson,et al.  The Determination of the Fluorescence Lifetimes of Dissolved Substances by a Phase Shift Method , 1953 .

[9]  D. Gloyna,et al.  Einfluß der Polarität und Viskosität des Lösungsmittels auf die Deaktivierung des S1-Zustandes von Donator-Akzeptor-substituiertentrans-Stilbenen , 1987 .

[10]  Stephen R. Meech,et al.  Standards for nanosecond fluorescence decay time measurements , 1983 .

[11]  D. O'connor,et al.  Time-Correlated Single Photon Counting , 1984 .

[12]  Joseph R. Lakowicz,et al.  A 10‐GHz frequency‐domain fluorometer , 1990 .

[13]  A. Safarzadeh-Amiri A time-resolved fluorescence study of the dynamic stokes shift of trans-4-dimethylamino-4'-cyanostilbene , 1986 .

[14]  A. Balter,et al.  A method of avoiding wavelength-dependent errors in decay-time measurements , 1979 .

[15]  P. R. Bevington,et al.  Data Reduction and Error Analysis for the Physical Sciences , 1969 .

[16]  A. Haddow,et al.  The growth-inhibitory and carcinogenic properties of 4-aminostilbene and derivatives , 1948, Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences.

[17]  S. Kinoshita,et al.  High‐performance, time‐correlated single photon counting apparatus using a side‐on type photomultiplier , 1982 .

[18]  James N. Demas,et al.  Excited State Lifetime Measurements , 1983 .

[19]  R. D. Spencer,et al.  Influence of Brownian Rotations and Energy Transfer upon the Measurements of Fluorescence Lifetime , 1970 .

[20]  J. Lakowicz,et al.  Analysis of fluorescence decay kinetics from variable-frequency phase shift and modulation data. , 1984, Biophysical journal.

[21]  Graham R. Fleming,et al.  Chemical applications of ultrafast spectroscopy , 1986 .

[22]  E Gratton,et al.  Phase fluorometric method for determination of standard lifetimes. , 1988, Analytical chemistry.

[23]  Joseph R. Lakowicz,et al.  Time-resolved laser spectroscopy in biochemistry II , 1990 .

[24]  Gary R. Holtom,et al.  Artifacts and diagnostics in fast fluorescence measurements , 1990, Photonics West - Lasers and Applications in Science and Engineering.

[25]  R. F. Chen,et al.  Fluorescence lifetime reference standards for the range 0.189 to 115 nanoseconds. , 1974, Analytical biochemistry.

[26]  G. Reinhart,et al.  Fluorescent Biomolecules , 1989, Springer US.

[27]  A. McKinnon,et al.  Confidence in fluorescence lifetime determinations: a ratio correction for the photomultiplier time response with wavelength , 1976 .

[28]  Joseph R. Lakowicz,et al.  2-GHz frequency-domain fluorometer , 1986 .

[29]  B. Maliwal,et al.  Construction and performance of a variable-frequency phase-modulation fluorometer. , 1985, Biophysical chemistry.

[30]  I. Yamazaki,et al.  Picosecond single photon timing measurements with a proximity type microchannel plate photomultiplier and global analysis with reference convolution , 1990 .

[31]  J. Lakowicz,et al.  Correction of timing errors in photomultiplier tubes used in phase-modulation fluorometry. , 1981, Journal of biochemical and biophysical methods.

[32]  E. Gratton,et al.  A continuously variable frequency cross-correlation phase fluorometer with picosecond resolution. , 1983, Biophysical journal.