Biomechanical Analysis of Nonconstrained and Semiconstrained Total Elbow Replacements: A Preliminary Report

The development of elbow arthroplasties has significantly improved the quality of life for many patients suffering from disabling elbow disorders. However, the high complication rate such as loosening and instability limits the long term use of total elbow replacement (TER). In the present study, biomechanical analyses on patients with unilateral nonconstrained (Souter-Strathclyde) and semiconstrained (Coonard-Morrey) TER subjects were performed to investigate differences of their motion patterns under unloaded and loaded conditions. In a biomechanical laboratory, each subject performed vertical and horizontal elbow flexion/extension first without and then with external loading (5 lb). The kinematic data were measured using 3D motion analysis system and the motion axis of the elbow was calculated by a well-defined mathematic model. During these tests, the upperarm was fixed with a special fixation device and their forearms fully supinated. The elbow motion patterns of the affected sides were compared with those of the normal sides and between different conditions. The results revealed that the elbows moved about a relatively fixed axis both in the semiconstrained and nonconstrained groups in the vertical flexion/extension with or without external loading, compatible with the normal elbows. However, the nonconstrained elbows were less stable during horizontal flexion/externsion motion with or without external loading and the elbow axis moved significantly, indicating of less stability. We conclude that this methodology of elbow motion analysis is acceptable and can be widely recommended for total elbow study. Moreover, the nonconstrained TER is less stable than the semiconstrained TER during the horizontal movement, which was compatible with previous clinical results. The patients with nonconstrained TER are suggested to avoid using their elbows in horizontal motion, especially in loaded conditions.

[1]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[2]  J. Gage,et al.  Gait analysis: principle and applications with emphasis on its use in cerebral palsy. , 1996, Instructional course lectures.

[3]  D. Sutherland,et al.  Measurement of gait movements from motion picture film. , 1972, The Journal of bone and joint surgery. American volume.

[4]  K. An,et al.  Kinematics of semi-constrained total elbow arthroplasty. , 1992, The Journal of bone and joint surgery. British volume.

[5]  Eric H Garling,et al.  Micromotion of the Souter-Strathclyde total elbow prosthesis in patients with rheumatoid arthritis , 2002, Acta orthopaedica Scandinavica.

[6]  Pj Udoh,et al.  Rigid Body Motion Calculated From Spatial Co-ordinates of Markers , 2010 .

[7]  T. Wright,et al.  Total elbow arthroplasty failure due to overuse, C-ring failure, and/or bushing wear. , 2005, Journal of shoulder and elbow surgery.

[8]  T. Brown,et al.  Assessment of elbow joint kinematics in passive motion by electromagnetic motion tracking , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[9]  James A. Johnson,et al.  Application of screw displacement axes to quantify elbow instability. , 2003, Clinical biomechanics.

[10]  R. Emery,et al.  Total elbow replacement in the treatment of rheumatoid disease. , 1999, Clinical orthopaedics and related research.

[11]  Kai-Nan An Kinematics and constraint of total elbow arthroplasty. , 2005, Journal of shoulder and elbow surgery.

[12]  Garth R Johnson,et al.  A study of the external forces and moments at the shoulder and elbow while performing every day tasks. , 2004, Clinical biomechanics.

[13]  A. Lundberg,et al.  Variation in the position and orientation of the elbow flexion axis. , 2003, The Journal of bone and joint surgery. British volume.

[14]  B. Morrey,et al.  Instability of the elbow treated with semiconstrained total elbow arthroplasty. , 1999, The Journal of bone and joint surgery. American volume.

[15]  G. King,et al.  Treatment of instability after total elbow arthroplasty. , 2001, The Orthopedic clinics of North America.

[16]  J. London Kinematics of the elbow. , 1981, The Journal of bone and joint surgery. American volume.

[17]  E. Chao,et al.  Passive motion of the elbow joint. , 1976, The Journal of bone and joint surgery. American volume.

[18]  F C Ewald Motion and laxity of the capitellocondylar total elbow prosthesis. , 1995, The Journal of bone and joint surgery. American volume.

[19]  K. An,et al.  Kinematics and functional characteristics of the Pritchard ERS unlinked total elbow arthroplasty. , 2003, Journal of shoulder and elbow surgery.

[20]  T. Thornhill,et al.  Revision of unstable capitellocondylar (unlinked) total elbow replacement. , 2005, The Journal of bone and joint surgery. American volume.

[21]  T. Lu,et al.  COMPARISONS OF JOINT KINETICS IN THE LOWER EXTREMITY BETWEEN STAIR ASCENT AND DESCENT , 2005 .

[22]  K. An,et al.  Importance of a Radial Head Component in Sorbie Unlinked Total Elbow Arthroplasty , 2002, Clinical orthopaedics and related research.

[23]  B F Morrey,et al.  Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics. , 1995, The Journal of arthroplasty.

[24]  F. Veldpaus,et al.  Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. , 1985, Journal of biomechanics.

[25]  Peter Giesl,et al.  Stability analysis of the elbow with a load. , 2004, Journal of theoretical biology.

[26]  M. Jacobs,et al.  Total Elbow Arthroplasty , 1984, Clinical orthopaedics and related research.