Noninvasive Evaluation of a Cutting Balloon Entrapped in a Left Main Coronary Artery Using Transesophageal Echocardiography

There are reports in the literature describing the utility of transesophageal echocardiography (TEE) in the evaluation of the coronary arteries. Studies have also shown the value of TEE in patients undergoing coronary intervention such as assessing coronary anatomy and flow following angioplasty. We report an interesting case where TEE helped to establish the location of a fractured cutting balloon device lodged in the left main coronary artery and obviated the need for cardiac surgery to remove the fractured balloon catheter. To our knowledge, this is the first case report of this type of complication utilizing a cutting balloon device.

[1]  T. Feldman,et al.  Interventional cardiology manpower needs: How many of us are there? how many should there be? how many will we need in the future? , 2003, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[2]  C. Liau,et al.  Coronary stent strut avulsion in aorto‐ostial in‐stent restenosis: Potential complication after cutting balloon angioplasty , 2002, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[3]  F. Ling,et al.  Inadvertent stent extraction six months after implantation by an entrapped cutting balloon , 2001, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[4]  H. Youn,et al.  Transesophageal echocardiography (TEE) in the evaluation of the coronary arteries. , 2000, Cardiology clinics.

[5]  E. Butchart,et al.  The vegetation that was not a vegetation: excusable misinterpretation of transesophageal echocardiography findings in late infective endocarditis of a prosthetic mitral valve. , 2000, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[6]  E. Isselbacher,et al.  The echocardiographic diagnosis, characterization, and extraction guidance of cardiac foreign bodies. , 2000, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[7]  I. Paraskevaidis,et al.  Transesophageal Doppler evaluation of left anterior descending coronary artery angioplasty. , 1997, The American journal of cardiology.

[8]  H. Rupprecht,et al.  Noninvasive Visualization of an Apparent Patent Intracoronary Stent by Transesophageal Echocardiography , 1995, Echocardiography.

[9]  K. Isaaz,et al.  Noninvasive assessment of coronary flow dynamics before and after coronary angioplasty using transesophageal Doppler. , 1993, The American journal of cardiology.

[10]  T. Bonzel,et al.  [Coronary stent implantation: infection and abscess with fatal outcome]. , 1993, Zeitschrift fur Kardiologie.