Performance limits of a 55-/spl mu/m pixel CdTe detector

In this work, the results from simulation of a CdTe pixel detector with a pixel size of 45 mum and a pitch of 55 mum are presented. Simulation of charge sharing between neighboring pixels has been compared with experimental results obtained by the use of the Medipix2 photon counting chip by means of a unique read-out system developed for the Dear-Mama project. Electrical simulations have been performed using the commercial software package DESSIS (ISETCAD) and combined with the Monte Carlo code GEANT4 to simulate the process of interaction and subsequent charge transport of charges induced by radiation. This allowed the analysis of charge sharing between pixel elements, an important limiting factor in imaging applications. Simulation was compared with experimental results obtained by means of a 1 mm thick CdTe detector. Each of these pixel electrodes was connected to the corresponding readout pixel on the Medipix2 chip, via an indium bump-bond. The backside contact was biased at -100 V, so that the pixel electrodes were collecting electrons. The results obtained imply that using a detector 1 mm thick with a pixel size smaller than 55 mum in single photon counting mode is unrealistic, because such fine spatial resolution cannot be attained in the corresponding image due to charge sharing

[1]  R. Dinapoli,et al.  Medipix2: A 64-k pixel readout chip with 55-/spl mu/m square elements working in single photon counting mode , 2001 .

[2]  M. Campbell,et al.  Signal variations in high-granularity Si pixel detectors , 2004, IEEE Transactions on Nuclear Science.

[3]  Aleksey E. Bolotnikov,et al.  Numerical modelling of charge-sharing in CdZnTe pixel detectors , 2000 .

[4]  G. Pellegrini,et al.  Charge sharing measurements of pixilated CdTe using Medipix-II chip , 2004, Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510).

[5]  Maria Grazia Pia,et al.  The Geant4 Toolkit: simulation capabilities and application results , 2003 .

[6]  X. Llopart,et al.  First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[7]  K. Mathieson,et al.  Simulation of charge transport in CdZnTe pixel detectors , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[8]  M. Henini,et al.  Properties of narrow gap cadmium-based compounds , 1995 .

[9]  B. Mikulec,et al.  Performance limits of a single photon counting pixel system , 2001 .