Hyperelastic Susceptibility Artifact Correction of DTI in SPM

Echo Planar Imaging (EPI) is a MRI acquisition technique that is the backbone of widely used investigation techniques in neuroscience like, e.g., Diffusion Tensor Imaging (DTI). While EPI offers considerable reduction of the acquisition time one major drawback is its high sensitivity to susceptibility artifacts. Susceptibility differences between soft tissue, bone and air cause geometrical distortions and intensity modulations of the EPI data. These susceptibility artifacts severely complicate the fusion of micro-structural information acquired with EPI and conventionally acquired structural information. In this paper, we introduce a new tool for hyperelastic susceptibility correction of DTI data (HySCO) that is integrated into the Statistical Parametric Mapping (SPM) software as a toolbox. Our new correction pipeline is based on two datasets acquired with reversed phase encoding gradients. For the correction, we integrated the variational image registration approach by Ruthotto et al. 2007 into the SPM batch mode. We briefly review the model, discuss involved parameter settings and exemplarily demonstrate the effectiveness of HySCO on a human brain DTI dataset.

[1]  D. Le Bihan,et al.  Diffusion tensor imaging: Concepts and applications , 2001, Journal of magnetic resonance imaging : JMRI.

[2]  Anders M. Dale,et al.  Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging , 2010, NeuroImage.

[3]  C. H. Wolters,et al.  Diffeomorphic Susceptibility Artefact Correction of Diffusion-Weighted Magnetic Resonance Images , 2012 .

[4]  J. Michael Fitzpatrick,et al.  A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities , 1992, IEEE Trans. Medical Imaging.

[5]  Jan Modersitzki,et al.  FAIR: Flexible Algorithms for Image Registration , 2009 .

[6]  J. Modersitzki,et al.  Diffeomorphic susceptibility artifact correction of diffusion-weighted magnetic resonance images , 2012, Physics in medicine and biology.

[7]  Nikolaus Weiskopf,et al.  Correction of vibration artifacts in DTI using phase-encoding reversal (COVIPER) , 2012, Magnetic resonance in medicine.

[8]  Stefan Skare,et al.  How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging , 2003, NeuroImage.

[9]  Robert Turner,et al.  Image Distortion Correction in fMRI: A Quantitative Evaluation , 2002, NeuroImage.

[10]  C. Pierpaoli,et al.  Characterization of and correction for eddy current artifacts in echo planar diffusion imaging , 1998, Magnetic resonance in medicine.

[11]  R. Turner,et al.  Echo-planar imaging: magnetic resonance imaging in a fraction of a second. , 1991, Science.