Anodic stripping voltammetric determination of cadmium using a "mercury free" indium film electrode.

In this work, the determination of cadmium has been attempted using an indium film electrode in the presence of bromide ions as an additive, for the first time. The electrode was prepared in situ on a glassy carbon substrate and employed in combination with square wave anodic stripping voltammetry. The purpose of having bromide ions is to enhance the analytical value of cadmium detection. In the absence of bromide ions, cadmium stripping peaks coalesce with indium and it is difficult to resolve for analytical purposes. The addition of bromide ions strongly influences the peak separation, thanks to the complex-forming characteristics of cadmium with bromide ions. Several key operational parameters influencing the electroanalytical response of indium modified electrodes were examined and optimized, such as deposition potential, pH, bromide ion and indium concentration. The indium modified electrode exhibited well-defined, separated stripping signals and revealed good linear behavior in the examined concentration range from 1 to 25 ng ml(-1). The present method shows a low detection limit value of 0.36 ng ml(-1). These results suggest that the proposed electrode contributes to the wider applicability of electrochemical stripping techniques in connection with "mercury-free" electrodes.

[1]  P. Gonzalez,et al.  Determination of nickel by anodic adsorptive stripping voltammetry with a cation exchanger-modified carbon paste electrode. , 2002, Talanta.

[2]  Rashid O. Kadara,et al.  In situ bismuth film modified screen printed electrodes for the bio-monitoring of cadmium in oral (saliva) fluid , 2010 .

[3]  Modified Composite Electrode Containing HgO as Built-In Mercury Precursor for Anodic Stripping Analysis of Trace Metals , 1998 .

[4]  S. Kaneko,et al.  Fabrication of column chip made of PMMA for μFIA. , 2011, Talanta.

[5]  V. Kašuba,et al.  Evaluation of genotoxic damage of cadmium chloride in peripheral blood of suckling Wistar rats , 2002, Journal of applied toxicology : JAT.

[6]  K. Brainina,et al.  Modified carbon-containing electrodes in stripping voltammetry of metals. Part II. Composite and microelectrodes , 2008 .

[7]  J Wang,et al.  Mercury-free disposable lead sensors based on potentiometric stripping analysis at gold-coated screen-printed electrodes. , 1993, Analytical chemistry.

[8]  V. Jovanovski,et al.  Ex Situ Prepared Antimony Film Electrode for Electrochemical Stripping Measurement of Heavy Metal Ions , 2009 .

[9]  Alexander Kuhn,et al.  Macroporous antimony film electrodes for stripping analysis of trace heavy metals , 2010 .

[10]  Samuel P. Kounaves,et al.  Microfabricated Array of Iridium Microdisks as a Substrate for Direct Determination of Cu2+ or Hg2+ Using Square-Wave Anodic Stripping Voltammetry , 1999 .

[11]  Guobao Xu,et al.  Electrochemical stripping analysis of cadmium on tantalum electrode , 2010 .

[12]  O. Vittori,et al.  Determination of cadmium in the presence of indium by polarography with addition of an electroinactive surfactant , 1983 .

[13]  Xiaobo Ji,et al.  Electroanalytical Determination of Cadmium(II) and Lead(II) Using an in-situ Bismuth Film Modified Edge Plane Pyrolytic Graphite Electrode , 2007, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[14]  T. Romann,et al.  Electrochemical properties of porous bismuth electrodes , 2010 .

[15]  K. Brainina,et al.  Modified carbon-containing electrodes in stripping voltammetry of metals , 2008 .

[16]  E. Hutton,et al.  Ex situ preparation of bismuth film microelectrode for use in electrochemical stripping microanalysis , 2005 .

[17]  Joseph Wang,et al.  A Decade with Bismuth‐Based Electrodes in Electroanalysis , 2010 .

[18]  Karel Vytras,et al.  Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrode , 2009 .

[19]  R. Hintsche,et al.  Highly sensitive heavy metal analysis on platinum- and gold-ultramicroelectrode arrays , 1997 .

[20]  A. Alfantazi,et al.  Processing of indium: a review , 2003 .

[21]  E. Kirowa-Eisner,et al.  Determination of nanomolar concentrations of lead and cadmium by anodic-stripping voltammetry at the silver electrode , 2002 .

[22]  Kangbing Wu,et al.  Voltammetric determination of Cd2+ based on the bifunctionality of single-walled carbon nanotubes-Nafion film. , 2007, Analytica chimica acta.

[23]  P. Unwin,et al.  Factors controlling stripping voltammetry of lead at polycrystalline boron doped diamond electrodes: new insights from high-resolution microscopy. , 2011, Analytical chemistry.

[24]  K Z Brainina,et al.  Stripping voltammetry in environmental and food analysis , 2000, Fresenius' journal of analytical chemistry.

[25]  Binggan Wei,et al.  A review of heavy metal contaminations in urban soils, urban road dusts and agricultural soils from China. , 2010 .

[26]  P. Fine,et al.  Sequential Selective Extraction Procedures for the Study of Heavy Metals in Soils, Sediments, and Waste Materials—a Critical Review , 2010 .

[27]  E. Norkus,et al.  Peculiarities of Electrochemical Bismuth Film Formation in the Presence of Bromide and Heavy Metal Ions , 2009 .

[28]  H. Luo,et al.  Anodic stripping voltammetric measurement of trace cadmium at tin-coated carbon paste electrode. , 2012, Talanta.

[29]  Wei Wang,et al.  Paper disk on screen printed electrode for one-step sensing with an internal standard. , 2010, Analytical chemistry.

[30]  Lu,et al.  Bismuth-coated carbon electrodes for anodic stripping voltammetry , 2000, Analytical chemistry.

[31]  Richard G. Compton,et al.  Electroanalytical Determination of Cadmium(II) and Lead(II) Using an Antimony Nanoparticle Modified Boron‐Doped Diamond Electrode , 2009 .

[32]  M. A. Alonso-Lomillo,et al.  Recent developments in the field of screen-printed electrodes and their related applications. , 2007, Talanta.

[33]  Joseph Wang,et al.  Stripping Analysis at Bismuth Electrodes: A Review , 2005 .

[34]  J. Osterloh,et al.  Indium as internal standard in square wave anodic stripping analysis of lead in blood with microelectrode arrays. , 1997, Analytical chemistry.

[35]  Karel Vytras,et al.  Antimony film electrode for electrochemical stripping analysis. , 2007, Analytical chemistry.

[36]  Wei Qin,et al.  An ionophore–Nafion modified bismuth electrode for the analysis of cadmium(II) , 2010 .

[37]  Ø. Mikkelsen,et al.  An Oscillating and Renewing Silver Electrode for Cadmium and Lead Detection in Differential Pulse Stripping Voltammetry , 2001 .

[38]  H. P. Wu Nature and Stability of Mercury Thin Films on Glassy Carbon Electrodes under Fast-Scan Anodic Stripping Voltammetry , 1994 .