Doppler echocardiography flow-velocity image analysis for patients with atrial fibrillation.

Currently, Doppler echocardiography analysis is performed manually. An automated method that analyzes the Doppler signal can potentially improve accuracy and result in a powerful tool for noninvasive evaluation of cardiac hemodynamics, especially for patients with atrial fibrillation, where multiple samples are needed to obtain an accurate averaged measurement. The aim of this study was to develop an automated method for Doppler analysis based on image processing and computer vision algorithms. Images were obtained from the mitral valve and the tricuspid valve Doppler tracings from 45 patients, 20 with normal sinus rhythm and 25 with atrial fibrillation. The proposed algorithm automatically detects the maximal velocity envelope of the spectral Doppler ultrasound tracings. Averaged values for the time velocity integral, peak mitral inflow velocity and peak tricuspid regurgitation velocity were calculated for multiple beats available in a single screen frame. Measurements extracted automatically from the maximal velocity envelope were compared to measurements obtained manually by two expert technicians. High linear correlation (r) was found between the automatically- and the manually-extracted parameters (0.95 < r < 0.99). A smaller variation was found in most cases between the manually-calculated average beat and the automated average beat (bias value between 3.8% and 5.2%) than between the manually-calculated average beat and the selection of a representative beat (bias value between 6.2% and -2.6%). The newly-developed automated method offers a new, accurate and reliable clinical tool, particularly for the assessment of patients with irregular heart rate.

[1]  Milan Sonka,et al.  Doppler blood velocity assessment based on image analysis of video-tape-recorded image data , 2001, SPIE Medical Imaging.

[2]  Milan Sonka,et al.  Automated analysis of Doppler ultrasound velocity flow diagrams , 2001, IEEE Transactions on Medical Imaging.

[3]  R A Nishimura,et al.  A clinical approach to the assessment of left ventricular diastolic function by Doppler echocardiography: update 2003 , 2003, Heart.

[4]  Lucas J. van Vliet,et al.  A nonlinear laplace operator as edge detector in noisy images , 1989, Comput. Vis. Graph. Image Process..

[5]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[6]  John E. Dennis,et al.  Numerical methods for unconstrained optimization and nonlinear equations , 1983, Prentice Hall series in computational mathematics.

[7]  David G. Stork,et al.  Pattern Classification , 1973 .

[8]  C. Asher,et al.  The role of echocardiography in atrial fibrillation and cardioversion , 2003, Heart.

[9]  S. Kovacs,et al.  Automated method for characterization of diastolic transmitral Doppler velocity contours: early rapid filling. , 1994, Ultrasound in medicine & biology.

[10]  D. Doherty,et al.  Estimation of the Doppler ultrasound maximal umbilical waveform envelope: I. Estimation method. , 2002, Ultrasound in medicine & biology.

[11]  R B D'Agostino,et al.  Intra- and interobserver reproducibility of Doppler-assessed indexes of left ventricular diastolic function in a population-based study (the Framingham Heart Study). , 1992, The American journal of cardiology.

[12]  S. Kovacs,et al.  Evaluation of model-based processing algorithms for averaged transmitral spectral Doppler images. , 1998, Ultrasound in medicine & biology.

[13]  S J Kovács,et al.  Echo machine-imposed limit on transmitral spectral Doppler velocity-profile analysis. , 1997, Ultrasound in medicine & biology.

[14]  S. Kovacs,et al.  Comparison of diastolic filling models and their fit to transmitral Doppler contours. , 1995, Ultrasound in medicine & biology.

[15]  C. Otto,et al.  Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. , 2002, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[16]  S. Kovacs,et al.  Beat averaging alternatives for transmitral Doppler flow velocity images. , 1998, Ultrasound in medicine & biology.

[17]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.