Effect of intraocular lens asphericity on quality of vision after cataract removal: an intraindividual comparison.

PURPOSE To determine the effect of intraocular lens (IOL) asphericity on quality of vision after cataract removal. DESIGN Intraindividual, prospective, randomized clinical trial. PARTICIPANTS Twenty-six cataract patients received 2, one-piece, blue-light-filtering hydrophobic acrylic IOLs each. METHODS One eye was implanted with a spherical (SN60AT, Alcon) and the contralateral eye with an aspheric (SN60WF, Alcon) IOL with -0.2 mum spherical aberration (SA). All trial-specific measurements (corneal topography, wavefront sensing, high-contrast visual acuity [HCVA], contrast sensitivity [CS]) were performed 6 months after surgery. A paired Student t-test or Wilcoxon test was used to check intergroup differences. MAIN OUTCOME MEASURES Absolute values and intraindividual differences (Delta(i)) of corneal and ocular higher order aberrations and best-corrected visual Strehl ratio based on the optical transfer function (BCVSOTF) values for virtual pupil diameters of 3, 4, 5, and 6 mm were computed. Photopic and mesopic HCVA, photopic, and high-mesopic CS as well as high-mesopic disability glare (DG) were measured using the Frankfurt-Freiburg Contrast and Acuity Test System. RESULTS No intergroup difference of demographic data, pupillometry, and corneal aberrations were observed. Coma and trefoil root mean square and SA were significantly lower in the aspheric group resulting in higher BCVSOTF, mesopic HCVA, and photopic and high mesopic CS. All Delta(i) values with exception of photopic HCVA and DG indicated significantly better performance of the aspheric IOL. CONCLUSIONS An aspheric IOL with -0.2 microm SA provide higher quality of vision than spherical IOL in terms of retinal image quality, mesopic HCVA and CS. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosures may be found after the references.

[1]  Michael Bach,et al.  The Freiburg Visual Acuity Test-Variability unchanged by post-hoc re-analysis , 2007, Graefe's Archive for Clinical and Experimental Ophthalmology.

[2]  Norberto López-Gil,et al.  Ocular wave-front aberration statistics in a normal young population , 2002, Vision Research.

[3]  T Kohnen,et al.  [Wavefront aberrations and subjective quality of vision after wavefront-guided LASIK: first results]. , 2007, Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[4]  Ed Geraghty,et al.  Effect of intraocular lens implantation on visual acuity, contrast sensitivity, and depth of focus , 2003, Journal of cataract and refractive surgery.

[5]  Roberto Bellucci,et al.  Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study , 2005, Journal of cataract and refractive surgery.

[6]  J. Bühren,et al.  Aberrationen höherer Ordnung nach Implantation einer irisgestützten Vorderkammerlinse (Ophtec Artisan®) in das phake Auge , 2004, Der Ophthalmologe.

[7]  Michael Bach,et al.  Measuring Contrast Sensitivity Under Different Lighting Conditions: Comparison of Three Tests , 2006, Optometry and vision science : official publication of the American Academy of Optometry.

[8]  Larry N Thibos,et al.  Measuring visual acuity--mesopic or photopic conditions, and high or low contrast letters? , 2004, Journal of refractive surgery.

[9]  Xu Cheng,et al.  Estimating visual quality from wavefront aberration measurements. , 2003, Journal of refractive surgery.

[10]  Walton Nosé,et al.  Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study. , 2006, American journal of ophthalmology.

[11]  Thomas Kohnen,et al.  Quality of Vision After Refractive Surgery , 2005 .

[12]  D. Koch,et al.  Higher‐order aberrations from the internal optics of the eye , 2005, Journal of cataract and refractive surgery.

[13]  Sergio Barbero,et al.  Optical aberrations of intraocular lenses measured in vivo and in vitro. , 2003, Journal of the Optical Society of America. A, Optics, image science, and vision.

[14]  Marrie van der Mooren,et al.  A new intraocular lens design to reduce spherical aberration of pseudophakic eyes. , 2002, Journal of refractive surgery.

[15]  Mark Packer,et al.  Improved functional vision with a modified prolate intraocular lens , 2004, Journal of cataract and refractive surgery.

[16]  Thomas Kohnen,et al.  Tilt and decentration of spherical and aspheric intraocular lenses: Effect on higher‐order aberrations , 2009, Journal of cataract and refractive surgery.

[17]  T. Kohnen,et al.  Incision sizes before and after implantation of 6-mm optic foldable intraocular lenses using Monarch and Unfolder injector systems. , 2005, Ophthalmology.

[18]  Corina van de Pol,et al.  Normal‐eye Zernike coefficients and root‐mean‐square wavefront errors , 2006, Journal of cataract and refractive surgery.

[19]  K. Pesudovs,et al.  Effect of cataract surgery incision location and intraocular lens type on ocular aberrations , 2005, Journal of cataract and refractive surgery.

[20]  R. Kershner,et al.  Retinal image contrast and functional visual performance with aspheric, silicone, and acrylic intraocular lenses: Prospective evaluation , 2003, Journal of cataract and refractive surgery.

[21]  Thomas Kohnen,et al.  Visual performance of aspherical and spherical intraocular lenses: Intraindividual comparison of visual acuity, contrast sensitivity, and higher‐order aberrations , 2006, Journal of cataract and refractive surgery.

[22]  T. Kohnen,et al.  Das „Frankfurt-Freiburg Contrast and Acuity Test System“ (FF-CATS) , 2005, Der Ophthalmologe.

[23]  T. Kohnen,et al.  Wellenfrontaberrationen und subjektive optische Qualität nach wellenfrontgeführter LASIK , 2007, Der Ophthalmologe.

[24]  Ulrich Mester,et al.  Impact of a modified optic design on visual function: Clinical comparative study , 2003, Journal of cataract and refractive surgery.

[25]  D. R. Iskander,et al.  Computational Aspects of the Visual Strehl Ratio , 2006, Optometry and vision science : official publication of the American Academy of Optometry.

[26]  T. Kohnen,et al.  [Frankfurt-Freiburg Contrast and Acuity Test System (FF-CATS). A new test to determine contrast sensitivity under variable ambient and glare luminance levels]. , 2005, Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[27]  Li Wang,et al.  Optical aberrations of the human anterior cornea , 2003, Journal of cataract and refractive surgery.

[28]  T. Kohnen,et al.  Cataract and refractive surgery , 2005 .

[29]  T. Kohnen,et al.  Intraindividual comparison of higher‐order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter , 2006, Journal of cataract and refractive surgery.

[30]  David Williams,et al.  Image Metrics for Predicting Subjective Image Quality , 2005, Optometry and vision science : official publication of the American Academy of Optometry.

[31]  Mark Packer,et al.  Prospective randomized trial of an anterior surface modified prolate intraocular lens. , 2002, Journal of refractive surgery.

[32]  Walton Nosé,et al.  Spherical aberration and depth of focus in eyes implanted with aspheric and spherical intraocular lenses: a prospective randomized study. , 2007, Ophthalmology.

[33]  Tobias Buehren,et al.  Accommodation stimulus–response function and retinal image quality , 2006, Vision Research.

[34]  Thomas Kohnen,et al.  Optic edge design as long-term factor for posterior capsular opacification rates. , 2008, Ophthalmology.

[35]  Robert Montés-Micó,et al.  Spherical aberration and contrast sensitivity after cataract surgery with the Tecnis Z9000 intraocular lens , 2006, Journal of cataract and refractive surgery.

[36]  N. Powe,et al.  Synthesis of the literature on visual acuity and complications following cataract extraction with intraocular lens implantation. Cataract Patient Outcome Research Team. , 1994, Archives of ophthalmology.

[37]  M. Khandwala,et al.  Rate of posterior capsule opacification in eyes with the Akreos intraocular lens , 2007, Journal of cataract and refractive surgery.

[38]  Spherical aberration and coma with an aspherical and a spherical intraocular lens in normal age‐matched eyes , 2007, Journal of cataract and refractive surgery.