Referenceless interleaved echo‐planar imaging

Interleaved echo‐planar imaging (EPI) is an ultrafast imaging technique important for applications that require high time resolution or short total acquisition times. Unfortunately, EPI is prone to significant ghosting artifacts, resulting primarily from system time delays that cause data matrix misregistration. In this work, it is shown mathematically and experimentally that system time delays are orientation dependent, resulting from anisotropic physical gradient delays. This analysis characterizes the behavior of time delays in oblique coordinates, and a new ghosting artifact caused by anisotropic delays is described. “Compensation blips” are proposed for time delay correction. These blips are shown to remove the effects of anisotropic gradient delays, eliminating the need for repeated reference scans and postprocessing corrections. Examples of phantom and in vivo images are shown. Magn Reson Med 41:87‐94, 1999. © 1999 Wiley‐Liss, Inc.

[1]  E R McVeigh,et al.  In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T , 1998, Magnetic resonance in medicine.

[2]  J. Felmlee,et al.  Echo-planar imaging of the liver with a standard MR imaging system. , 1993, Radiology.

[3]  M A Bernstein,et al.  Angle‐dependent utilization of gradient hardware for oblique MR imaging , 1994, Journal of magnetic resonance imaging : JMRI.

[4]  R. Turner,et al.  Echo-planar imaging: magnetic resonance imaging in a fraction of a second. , 1991, Science.

[5]  G. Mckinnon Ultrafast interleaved gradient‐echo‐planar imaging on a standard scanner , 1993, Magnetic resonance in medicine.

[6]  E R McVeigh,et al.  Multi‐echo segmented k‐space imaging: An optimized hybrid sequence for ultrafast cardiac imaging , 1999, Magnetic resonance in medicine.

[7]  E R McVeigh,et al.  Quantification and reduction of ghosting artifacts in interleaved echo‐planar imaging , 1997, Magnetic resonance in medicine.

[8]  Alan V. Oppenheim,et al.  Discrete-time Signal Processing. Vol.2 , 2001 .

[9]  K. Kwong Functional magnetic resonance imaging with echo planar imaging. , 1995, Magnetic resonance quarterly.

[10]  E R McVeigh,et al.  Minimization of dead‐periods in MRI pulse sequences for imaging oblique planes , 1994, Magnetic resonance in medicine.

[11]  Z H Cho,et al.  Analysis of eddy currents in nuclear magnetic resonance imaging , 1991, Magnetic resonance in medicine.

[12]  Robert Turner,et al.  Single-shot diffusion imaging at 2.0 tesla , 1990 .

[13]  M E Moseley,et al.  Ultrafast magnetic resonance imaging: diffusion and perfusion. , 1991, Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes.

[14]  D. Feinberg,et al.  GRASE (Gradient‐and Spin‐Echo) imaging: A novel fast MRI technique , 1991, Magnetic resonance in medicine.

[15]  H Bruder,et al.  Image reconstruction for echo planar imaging with nonequidistant k‐space sampling , 1992, Magnetic resonance in medicine.

[16]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .