Quantification of metal artifacts in computed tomography: methodological considerations.

Numerous methods for artifact quantification in computed tomography (CT) imaging have been suggested. This study evaluated their utility with regards to correspondence with visual artifact perception and reproducibility. Two titanium rods (5 and 10 mm) were examined with 25 different scanning- and image-reconstruction parameters resulting in different types and extents of artifacts. Four radiologists evaluated every image against each other using an in-house developed software. Rating was repeated two times (2,400 comparisons = 2 times × 4 readers × 300 comparisons). Rankings were combined to obtain a reference ranking. Proposed approaches for artifact quantification include manual measurement of attenuation, standard deviation and noise and sophisticated algorithm-based approaches within the image- and frequency-domain. Two radiologists conducted manual measurements twice while the aforementioned algorithms were implemented within the Matlab-Environment allowing for automated image analysis. The reference ranking was compared to all aforementioned methods for artifact quantification to identify suited approaches. Besides visual analysis, Kappa-statistics and intraclass correlation coefficients (ICC) were used. Intra- and Inter-reader agreements of visual artifact perception were excellent (ICC 0.85-0.92). No quantitative method was able to represent the exact ranking of visually perceived artifacts; however, ICC for manual measurements were low (ICC 0.25-0.97). The method that showed best correspondence and reproducibility used a Fourier-transformed linear ROI and lower-end frequency bins. Automated measurements of artifact extent should be preferred over manual measurements as the latter show a limited reproducibility. One method that allows for automated quantification of such artefacts is made available as an electronic supplement.

[1]  Marc Kachelrieß,et al.  Dual energy CT: how well can pseudo-monochromatic imaging reduce metal artifacts? , 2015, Medical physics.

[2]  J. Milles,et al.  Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses. , 2017, European journal of radiology.

[3]  K. Laukamp,et al.  Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms , 2018, Skeletal Radiology.

[4]  Simon S. Martin,et al.  Dual energy computed tomography virtual monoenergetic imaging: technique and clinical applications. , 2019, The British journal of radiology.

[5]  Francesco C Stingo,et al.  An evaluation of three commercially available metal artifact reduction methods for CT imaging , 2015, Physics in medicine and biology.

[6]  G. Andreisek,et al.  Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels , 2012, European Radiology.

[7]  Robert Rau,et al.  Metal artifact reduction by dual-layer computed tomography using virtual monoenergetic images. , 2017, European journal of radiology.

[8]  Shuai Leng,et al.  Dual-energy CT-based monochromatic imaging. , 2012, AJR. American journal of roentgenology.

[9]  Arnold M. R. Schilham,et al.  Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality , 2013, European Radiology.

[10]  Yue Dong,et al.  Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT , 2016, European Spine Journal.

[11]  D. Maintz,et al.  CT metal artifacts in patients with total hip replacements: for artifact reduction monoenergetic reconstructions and post-processing algorithms are both efficient but not similar , 2018, European Radiology.

[12]  Jin-Suck Suh,et al.  Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software , 2012, European Radiology.

[13]  P. Noël,et al.  The evolution of image reconstruction for CT—from filtered back projection to artificial intelligence , 2018, European radiology.

[14]  Konstantin Nikolaou,et al.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation , 2011, European Radiology.

[15]  Gerald Antoch,et al.  Metal Artifact Reduction in Computed Tomography After Deep Brain Stimulation Electrode Placement Using Iterative Reconstructions , 2017, Investigative radiology.

[16]  Ming Liu,et al.  Open Access Background , 2000 .

[17]  Rebecca Fahrig,et al.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging. , 2014, Medical physics.

[18]  Sergios Gatidis,et al.  Single-Source Dual-Energy Computed Tomography: Use of Monoenergetic Extrapolation for a Reduction of Metal Artifacts , 2014, Investigative radiology.

[19]  M. Uder,et al.  A Novel Pairwise Comparison-Based Method to Determine Radiation Dose Reduction Potentials of Iterative Reconstruction Algorithms, Exemplified Through Circle of Willis Computed Tomography Angiography , 2016, Investigative radiology.

[20]  K Harada,et al.  Reduction of dental metallic artefacts in CT: value of a newly developed algorithm for metal artefact reduction (O-MAR). , 2014, Clinical radiology.

[21]  Simon Lennartz,et al.  Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts , 2019, European Radiology.

[22]  W. Capello,et al.  Multichannel CT Imaging of Orthopedic Hardware and Implants , 2006, Seminars in musculoskeletal radiology.

[23]  David Maintz,et al.  Reduction of Artifacts Caused by Deep Brain Stimulating Electrodes in Cranial Computed Tomography Imaging by Means of Virtual Monoenergetic Images, Metal Artifact Reduction Algorithms, and Their Combination , 2018, Investigative radiology.

[24]  Thoracic-abdominal imaging with a novel dual-layer spectral detector CT: intra-individual comparison of image quality and radiation dose with 128-row single-energy acquisition , 2018, Acta radiologica.

[25]  D. Maintz,et al.  Artifact reduction from dental implants using virtual monoenergetic reconstructions from novel spectral detector CT. , 2018, European journal of radiology.