Angle Instability Detection in Power Systems With High-Wind Penetration Using Synchrophasor Measurements

The alternating current machines in a power system have the ability to remain synchronized following a severe disturbance such as loss of generations, line switching, or fault. This is described as power system transient stability. During system transients, the machines will accelerate or decelerate because of the mismatch between electrical torque and mechanical torque. Their power angles will travel and finally settle down to a new equilibrium, if the system has enough stored energy to absorb the disturbance, and rest the system at another steady state. In case of system instability, some machines will have aperiodic angular separation from the rest of the system and finally lose synchronization. Therefore, the power system transient stability is also called angle stability. The total system inertia is an essential force to rest the system transient. The inertias stored in all rotating masses that are connected to a power system, such as synchronous generators and induction motors, typically respond to disturbances voluntarily, without any control actions; however, several types of renewable generation, particularly those with power electronic interfaces, have an inertial response governed by a control function. To ensure bulk power system stability, there is a need to estimate the equivalent inertia available from a renewable generation plant. An equivalent voluntary inertia constant analogous to that of conventional rotating machines can be used to provide a readily understandable metric, such as the angle instabilities detections, because one of the most difficult obstacles for angle instability detection is the knowledge of the real-time generator inertias. This paper explores a method that utilizes synchrophasor measurements to estimate the equivalent inertia of a power source such as synchronous generators or wind turbine generators. This paper also investigates the angle instability detection method for a system with high wind power penetration using the synchrophasor measurements.

[1]  Durga Gautam Impact of Increased Penetration of DFIG Based Wind Turbine Generators on Rotor Angle Stability of Power Systems , 2010 .

[2]  Shun-Hsien Huang,et al.  System Inertial Frequency Response estimation and impact of renewable resources in ERCOT interconnection , 2011, 2011 IEEE Power and Energy Society General Meeting.

[3]  S. Santoso,et al.  Understanding inertial and frequency response of wind power plants , 2012, 2012 IEEE Power Electronics and Machines in Wind Applications.

[4]  M.V.A. Nunes,et al.  Influence of the variable-speed wind generators in transient stability margin of the conventional generators integrated in electrical grids , 2004 .

[5]  E. Muljadi,et al.  Effect of Variable Speed Wind Turbine Generator on Stability of a Weak Grid , 2007, IEEE Transactions on Energy Conversion.

[6]  D.P. Chassin,et al.  Estimation of WECC system inertia using observed frequency transients , 2004, IEEE Transactions on Power Systems.

[7]  H. Banakar,et al.  Kinetic Energy of Wind-Turbine Generators for System Frequency Support , 2009, IEEE Transactions on Power Systems.

[8]  J.A. Ferreira,et al.  Wind turbines emulating inertia and supporting primary frequency control , 2006, IEEE Transactions on Power Systems.

[9]  Zhiyong Yuan,et al.  Wide-Area Frequency Monitoring Network (FNET) Architecture and Applications , 2010, IEEE Transactions on Smart Grid.

[10]  P. Kundur,et al.  Power system stability and control , 1994 .

[11]  James S. Thorp,et al.  Continuum modeling of electromechanical dynamics in large-scale power systems , 2004, IEEE Transactions on Circuits and Systems I: Regular Papers.

[12]  V. Venkatasubramanian,et al.  New Wide-Area Algorithms for Detection and Mitigation of Angle Instability using Synchrophasors , 2007, 2007 IEEE Power Engineering Society General Meeting.

[13]  T. Inoue,et al.  Estimation of power system inertia constant and capacity of spinning-reserve support generators using measured frequency transients , 1997 .

[14]  B. Fox,et al.  Measurement-based estimation of wind farm inertia , 2005, 2005 IEEE Russia Power Tech.

[15]  Y. Liu,et al.  Generator Trip Identification Using Wide-Area Measurements and Historical Data Analysis , 2006, 2006 IEEE PES Power Systems Conference and Exposition.

[16]  K. Clark,et al.  Frequency responsive wind plant controls: Impacts on grid performance , 2011, 2011 IEEE Power and Energy Society General Meeting.

[17]  A. Mullane,et al.  Frequency control and wind turbine technologies , 2005, IEEE Transactions on Power Systems.

[18]  F. Gonzalez-Longatt,et al.  Estimation of generator inertia available during a disturbance , 2012, 2012 IEEE Power and Energy Society General Meeting.