Impact of CT and 18F-deoxyglucose positron emission tomography image fusion for conformal radiotherapy in esophageal carcinoma.

PURPOSE To study the impact of fused (18)F-fluoro-deoxy-D-glucose (FDG)-hybrid positron emission tomography (PET) and computed tomography (CT) images on conformal radiotherapy planning for esophageal carcinoma patients. METHODS AND MATERIALS Thirty-four esophageal carcinoma patients were referred for concomitant radiotherapy and chemotherapy with radical intent. Each patient underwent CT and FDG-hybrid PET for simulation treatment in the same treatment position. PET images were coregistered using five fiducial markers. Target delineation was initially performed on CT images, and the corresponding PET data were subsequently used as an overlay to CT data to define the target volume. RESULTS (18)F-fluorodeoxy-D-glucose-PET identified previously undetected distant metastatic disease in 2 patients, making them ineligible for curative conformal radiotherapy. The gross tumor volume (GTV) was decreased by CT and FDG image fusion in 12 patients (35%) and increased in 7 patients (21%). The GTV reduction was > or =25% in 4 patients owing to a reduction in the length of the esophageal tumor. The GTV increase was > or =25% with FDG-PET in 2 patients owing to the detection of occult mediastinal lymph node involvement in 1 patient and an increased length of the esophageal tumor in 1 patient. Modifications of the GTV affected the planning treatment volume in 18 patients. Modifications of the delineation of the GTV and displacement of the isocenter of the planning treatment volume by FDG-PET also affected the percentage of total lung volume receiving >20 Gy in 25 patients (74%), with a dose reduction in 12 patients and dose increase in 13. CONCLUSION In our study, CT and FDG-PET image fusion appeared to have an impact on treatment planning and management of esophageal carcinoma. The affect on treatment outcome remains to be demonstrated.

[1]  O. Sabri,et al.  Dual-head gamma camera 2-[fluorine-18]-fluoro-2-deoxy-d-glucose positron emission tomography in oncological patients: effects of non-uniform attenuation correction on lesion detection , 1999, European Journal of Nuclear Medicine.

[2]  R. Hicks,et al.  A comparison of MRI and PET scanning in surgically staged loco-regionally advanced cervical cancer: Potential impact on treatment , 2001, International Journal of Gynecologic Cancer.

[3]  Y. Shim,et al.  Evaluation of lymph node metastases in squamous cell carcinoma of the esophagus with positron emission tomography. , 2001, The Annals of thoracic surgery.

[4]  Douglas L. Jones ICRU Report 50—Prescribing, Recording and Reporting Photon Beam Therapy , 1994 .

[5]  Sasa Mutic,et al.  Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer. , 2004, International journal of radiation oncology, biology, physics.

[6]  M. Goitein,et al.  Tolerance of normal tissue to therapeutic irradiation. , 1991, International journal of radiation oncology, biology, physics.

[7]  R. Hustinx,et al.  Positron emission tomography (PET) with 18F-fluorodeoxyglucose (18F-FDG) for the staging of low-grade non-Hodgkin's lymphoma (NHL). , 2001, Annals of oncology : official journal of the European Society for Medical Oncology.

[8]  C B Caldwell,et al.  Observer variation in contouring gross tumor volume in patients with poorly defined non-small-cell lung tumors on CT: the impact of 18FDG-hybrid PET fusion. , 2001, International journal of radiation oncology, biology, physics.

[9]  G. Patterson,et al.  Improvement in staging of esophageal cancer with the addition of positron emission tomography. , 1997, The Annals of thoracic surgery.

[10]  M. Tatsumi,et al.  Feasibility of fluorodeoxyglucose dual-head gamma camera coincidence imaging in the evaluation of lung cancer: comparison with FDG PET. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  R. Wahl,et al.  Oncologic diagnosis with 2-[fluorine-18]fluoro-2-deoxy-D-glucose imaging: dual-head coincidence gamma camera versus positron emission tomographic scanner. , 1998, Radiology.

[12]  J. Patton,et al.  Comparison of FDG PET and positron coincidence detection imaging using a dual-head gamma camera with 5/8-inch NaI(Tl) crystals in patients with suspected body malignancies , 1999, European Journal of Nuclear Medicine.

[13]  B A Fraass,et al.  The development of conformal radiation therapy. , 1995, Medical physics.

[14]  Gerald J. Kutcher,et al.  The impact of 18F-fluoro-2-deoxy-d-glucose positron emission tomography (FDG-PET) lymph node staging on the radiation treatment volumes in patients with non-small cell lung cancer , 2000 .

[15]  John L. Humm,et al.  Radiotherapy treatment planning for patients with non-small cell lung cancer using positron emission tomography (PET). , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[16]  G. Cook,et al.  Computed tomography and positron emission tomography in the pre-operative staging of oesophageal carcinoma. , 1998, Clinical radiology.

[17]  J A Purdy,et al.  Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC) , 1999, International journal of radiation oncology, biology, physics.

[18]  M. Mix,et al.  Metastatic lymph nodes in patients with cervical cancer: detection with MR imaging and FDG PET. , 2001, Radiology.

[19]  E. Pauwels,et al.  The clinical value of 18F-FDG detection with a dual-head coincidence camera: a review , 2001, European Journal of Nuclear Medicine.

[20]  Cyrill Burger,et al.  PET-CT image co-registration in the thorax: influence of respiration , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[21]  V Kalff,et al.  F‐18 fluorodeoxyglucose positron emission tomography staging in radical radiotherapy candidates with nonsmall cell lung carcinoma , 2001, Cancer.

[22]  J C Rosenwald,et al.  CT and (18)F-deoxyglucose (FDG) image fusion for optimization of conformal radiotherapy of lung cancers. , 2001, International journal of radiation oncology, biology, physics.

[23]  Tohru Shiga,et al.  Image fusion between 18FDG-PET and MRI/CT for radiotherapy planning of oropharyngeal and nasopharyngeal carcinomas. , 2002, International journal of radiation oncology, biology, physics.

[24]  Kyung-Han Lee,et al.  Improved detection of individual nodal involvement in squamous cell carcinoma of the esophagus by FDG PET. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  F Dehdashti,et al.  Staging of esophageal cancer with 18F-fluorodeoxyglucose positron emission tomography. , 1997, AJR. American journal of roentgenology.

[26]  J. Talbot,et al.  [18F]-FDG positron imaging in clinical management of lymphoma patients. , 2001, Critical reviews in oncology/hematology.

[27]  Cyrill Burger,et al.  Radiation treatment planning with an integrated positron emission and computer tomography (PET/CT): a feasibility study. , 2003, International journal of radiation oncology, biology, physics.

[28]  K Schnabel,et al.  18F-deoxyglucose positron emission tomography (FDG-PET) for the planning of radiotherapy in lung cancer: high impact in patients with atelectasis. , 1999, International journal of radiation oncology, biology, physics.

[29]  J Kotzerke,et al.  2‐(fluorine‐18)fluoro‐2‐deoxy‐D‐glucose positron emission tomography in the detection and staging of malignant lymphoma , 2001, Cancer.

[30]  T. Yen,et al.  Value of dual-phase 2-fluoro-2-deoxy-d-glucose positron emission tomography in cervical cancer. , 2003, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[31]  F. Maul,et al.  Whole body positron emission tomography in the treatment of Hodgkin disease , 2001, Cancer.

[32]  P. Dupont,et al.  Utility of positron emission tomography for the staging of patients with potentially operable esophageal carcinoma. , 2000, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[33]  Sasa Mutic,et al.  PET-guided IMRT for cervical carcinoma with positive para-aortic lymph nodes-a dose-escalation treatment planning study. , 2003, International journal of radiation oncology, biology, physics.

[34]  Peter Bartenstein,et al.  Imaging of lung cancer with fluorine-18 fluorodeoxyglucose: comparison of a dual-head gamma camera in coincidence mode with a full-ring positron emission tomography system , 1999, European Journal of Nuclear Medicine.

[35]  M. Mehta,et al.  The value of PET/CT in gross tumor volume delineation in lung and esophagus cancer , 2004 .

[36]  G. Urso,et al.  Role of positron emission tomography in staging esophageal cancer. , 1997, The Annals of thoracic surgery.

[37]  K. Yuen,et al.  A prospective study to evaluate the impact of coregistered PET/CT images on radiotherapy treatment planning for esophageal cancer , 2004 .

[38]  J. Luketich,et al.  Whole-Body FDG Positron Emission Tomographic Imaging for Staging Esophageal Cancer: Comparison with Computed Tomography , 2000, Clinical nuclear medicine.