A surface loop array for in vivo small animal MRI/fMRI on 7T human scanners.

Small animals such as non-human primate (NHP) and rodent are valuable models in frontier neuroscience researches, and comparative research between the animal model and human is helpful to understand and reveal the functional brain circuits in cognition and underlying mechanism in psychological disease. Small animals can be trained or anesthetized to endure long-term and multiple imaging scans; however, the concomitant needs in subcortical structure and function investigations pose major challenges in, e.g. spatial resolution, scan time efficiency, spatial/temporal signal-to-noise-ratio, as well as apparatus mechanical fixation. In addition, comparative investigations across species are also expected to be conducted under similar physical environment (such as the main magnetic field strength, RF pulse shape, sequence protocols, gradient waveform, system stability, etc in MRI), in order to avoid possible deviation in signal detection under different platforms, as well as to reduce experiment complexity. We have proposed a novel 5-channel surface coil that is equipped on 7T human MRI scanners and designed for small animal structural and functional MRI. Through a series of in vivo experiments over an anesthetized rat and macaque, the presented coil shows its main characteristics in, i.e. flexible coil mounting, reduced FOV, high temporal SNR, and parallel imaging capability. Such design is able to compensate the relatively lower gradient slew rate of human scanners versus those with smaller bores, and thus effectively facilitates in vivo microscopic structural MR images being obtained within a shortened and safe period of anesthesia; besides, it also enables high-resolution functional MRI (i.e. spin-echo based) being achieved with reasonable temporal resolution, distortion level and functional contrast.

[1]  Essa Yacoub,et al.  Variable flip angle 3D‐GRASE for high resolution fMRI at 7 tesla , 2016, Magnetic resonance in medicine.

[2]  Peter Kellman,et al.  Image reconstruction in SNR units: A general method for SNR measurement † , 2005, Magnetic resonance in medicine.

[3]  M Rudin MR microscopy on rats in vivo at 4.7 T using surface coils , 1987, Magnetic resonance in medicine.

[4]  Chia-Chun Hung,et al.  Design and implementation of embedded 8‐channel receive‐only arrays for whole‐brain MRI and fMRI of conscious awake marmosets , 2017, Magnetic resonance in medicine.

[5]  Joseph S. Gati,et al.  Optimized parallel transmit and receive radiofrequency coil for ultrahigh-field MRI of monkeys , 2016, NeuroImage.

[6]  Stefan Neubauer,et al.  Suppression of skeletal muscle signal using a crusher coil: A human cardiac 31p‐MR spectroscopy study at 7 tesla , 2015, Magnetic resonance in medicine.

[7]  Xiaotong Zhang,et al.  Investigating the Influence of Spatial Constraints on Ultimate Receive Coil Performance for Monkey Brain MRI at 7 T , 2018, IEEE Transactions on Medical Imaging.

[8]  Jürgen Finsterbusch,et al.  Simultaneous functional MRI acquisition of distributed brain regions with high temporal resolution using a 2D‐selective radiofrequency excitation , 2015, Magnetic resonance in medicine.

[9]  Bin He,et al.  From Complex ${\rm B}_{1}$ Mapping to Local SAR Estimation for Human Brain MR Imaging Using Multi-Channel Transceiver Coil at 7T , 2013, IEEE Transactions on Medical Imaging.

[10]  Ravi S. Menon,et al.  Submillimeter functional localization in human striate cortex using BOLD contrast at 4 Tesla: Implications for the vascular point‐spread function , 1999, Magnetic resonance in medicine.

[11]  Azma Mareyam,et al.  A 22‐channel receive array with Helmholtz transmit coil for anesthetized macaque MRI at 3 T , 2013, NMR in biomedicine.

[12]  Nikos K Logothetis,et al.  Laminar specificity in monkey V1 using high-resolution SE-fMRI. , 2006, Magnetic resonance imaging.

[13]  Essa Yacoub,et al.  Robust detection of ocular dominance columns in humans using Hahn Spin Echo BOLD functional MRI at 7 Tesla , 2007, NeuroImage.

[14]  T. Robbins,et al.  Functions of frontostriatal systems in cognition: Comparative neuropsychopharmacological studies in rats, monkeys and humans , 2006, Biological Psychology.

[15]  Bin He,et al.  Complex B1 mapping and electrical properties imaging of the human brain using a 16‐channel transceiver coil at 7T , 2013, Magnetic resonance in medicine.

[16]  Gang Chen,et al.  Identification of cortical lamination in awake monkeys by high resolution magnetic resonance imaging , 2012, NeuroImage.

[17]  Ravi S. Menon,et al.  Concentric radiofrequency arrays to increase the statistical power of resting-state maps in monkeys , 2018, NeuroImage.

[18]  J. Price,et al.  The organization of networks within the orbital and medial prefrontal cortex of rats, monkeys and humans. , 2000, Cerebral cortex.

[19]  Vasily L Yarnykh,et al.  Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency field , 2007, Magnetic resonance in medicine.

[20]  Ravi S. Menon,et al.  A geometrically adjustable receive array for imaging marmoset cohorts , 2017, NeuroImage.

[21]  B. Keil,et al.  An implanted 8-channel array coil for high-resolution macaque MRI at 3T , 2012, NeuroImage.

[22]  Bin He,et al.  Quantitative prediction of radio frequency induced local heating derived from measured magnetic field maps in magnetic resonance imaging: A phantom validation at 7 T. , 2014, Applied physics letters.

[23]  You-Yin Chen,et al.  Ultra high-resolution fMRI and electrophysiology of the rat primary somatosensory cortex , 2013, NeuroImage.

[24]  N. Logothetis,et al.  Ultra High-Resolution fMRI in Monkeys with Implanted RF Coils , 2002, Neuron.

[25]  Gang Chen,et al.  Layer-specific BOLD activation in awake monkey V1 revealed by ultra-high spatial resolution functional magnetic resonance imaging , 2013, NeuroImage.

[26]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[27]  Daniel K Sodickson,et al.  A high-impedance detector-array glove for magnetic resonance imaging of the hand , 2018, Nature Biomedical Engineering.

[28]  Lawrence L. Wald,et al.  Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coils , 2011, NeuroImage.

[29]  Essa Yacoub,et al.  High-field fMRI unveils orientation columns in humans , 2008, Proceedings of the National Academy of Sciences.

[30]  Christina Triantafyllou,et al.  A 20‐channel receive‐only mouse array coil for a 3 T clinical MRI system , 2011, Magnetic resonance in medicine.

[31]  Hellmut Merkle,et al.  An embedded four‐channel receive‐only RF coil array for fMRI experiments of the somatosensory pathway in conscious awake marmosets , 2013, NMR in biomedicine.

[32]  Lawrence L. Wald,et al.  Laminar analysis of 7T BOLD using an imposed spatial activation pattern in human V1 , 2010, NeuroImage.

[33]  Josef Pfeuffer,et al.  Isotropic submillimeter fMRI in the human brain at 7 T: Combining reduced field‐of‐view imaging and partially parallel acquisitions , 2012, Magnetic resonance in medicine.

[34]  Dae-Shik Kim,et al.  High-resolution mapping of iso-orientation columns by fMRI , 2000, Nature Neuroscience.

[35]  Keiji Tanaka,et al.  Human Ocular Dominance Columns as Revealed by High-Field Functional Magnetic Resonance Imaging , 2001, Neuron.