Passive strain distribution in the interosseous ligament of the forearm: implications for injury reconstruction.

PURPOSE For severe forearm injuries such as an Essex-Lopresti fracture-dislocation, functional reconstruction necessitates repair of the interosseous ligament (IOL) to restore normal load sharing between the radius and ulna. Locating or tensioning such a reconstruction improperly can lead to abnormal load sharing and/or restriction of forearm rotation. The normal IOL strains should indicate the proper location of reconstruction grafts and the proper forearm rotation for tensioning the grafts. The objective of this study was to quantify the passive strain distribution of the IOL of the forearm with passive rotation of the forearm throughout the range of motion. METHODS The 3-dimensional motions of the radius with respect to the ulna were measured throughout forearm rotation in 10 cadaveric forearms by using an instrumented spatial linkage. From the bone motions and ligament insertion site geometry from dissection and computed tomographic scanning, insertion site motions were determined and used to calculate changes in ligament fiber lengths. RESULTS The measured strain distribution in the IOL was nonuniform and varied with forearm rotation. The overall magnitude of IOL strain was found to be greatest in supination and smallest in pronation. In supination the strains varied across fibers with strains being greatest in the distal fibers and lowest in the proximal fibers. Strains in neutral rotation were uniform across fibers. Although fibers were generally slack in pronation proximal fibers were less slack than distal fibers. CONCLUSIONS The results of this study indicate that fiber strains in the IOL vary from proximal to distal and depend on forearm rotation. Our data suggest that to prevent restriction of forearm rotation all grafts should be tensioned in supination, where measured strains were generally highest. Our data also suggest that a 2-bundle IOL reconstruction may be necessary for proper load transfer between the radius and ulna in both supination and pronation.

[1]  W. Cooney,et al.  Radio-ulnar dissociation. A review of twenty cases. , 1992, The Journal of bone and joint surgery. American volume.

[2]  S L Woo,et al.  A method for measuring joint kinematics designed for accurate registration of kinematic data to models constructed from CT data. , 2001, Journal of biomechanics.

[3]  J. Skahen,et al.  Reconstruction of the interosseous membrane of the forearm in cadavers. , 1997, The Journal of hand surgery.

[4]  J. Skahen,et al.  The interosseous membrane of the forearm: anatomy and function. , 1997, The Journal of hand surgery.

[5]  Hotchkiss Rn,et al.  Injuries to the interosseous ligament of the forearm. , 1994 .

[6]  J. Plewes,et al.  Measurement of joint motion: A guide to goniometry , 1986 .

[7]  E. Chao,et al.  Silastic prosthetic replacement for the radial head. , 1981, The Journal of bone and joint surgery. American volume.

[8]  A. Sarmiento,et al.  The interosseous membrane of the forearm: structure and its role in Galeazzi fractures. , 1993, The Journal of trauma.

[9]  T. Nakamura,et al.  Three-dimensional magnetic resonance imaging of the interosseous membrane of forearm: a new method using fuzzy reasoning. , 1999, Magnetic resonance imaging.

[10]  J. Jupiter,et al.  Radial Head Fractures with Acute Distal Radioulnar Dislocation: Essex‐Lopresti Revisited , 1988, Clinical orthopaedics and related research.

[11]  W. Kleinman,et al.  Disorders of the forearm axis. , 1998, Hand clinics.

[12]  S L Woo,et al.  A new methodology to measure load transfer through the forearm using multiple universal force sensors. , 1999, Journal of biomechanics.

[13]  D P Fyhrie,et al.  The interosseous membrane affects load distribution in the forearm. , 1997, The Journal of hand surgery.

[14]  S. Woo,et al.  Effects of postmortem storage by freezing on ligament tensile behavior. , 1986, Journal of biomechanics.

[15]  A. Palmer,et al.  The triangular fibrocartilage complex of the wrist--anatomy and function. , 1981, The Journal of hand surgery.

[16]  M. Tomaino,et al.  Forearm rotation alters interosseous ligament strain distribution. , 2000, The Journal of hand surgery.

[17]  James H. Herndon,et al.  Tensile properties of the interosseous membrane of the human forearm , 1996 .

[18]  K. An,et al.  An anatomic and mechanical study of the interosseous membrane of the forearm: pathomechanics of proximal migration of the radius. , 1989, The Journal of hand surgery.

[19]  K. Markolf,et al.  Radioulnar Load-Sharing in the Forearm. A Study in Cadavera* , 1998, The Journal of bone and joint surgery. American volume.

[20]  S. Woo,et al.  Role of the forearm interosseous ligament: is it more than just longitudinal load transfer? , 2000, The Journal of hand surgery.