Fabrication of multilayer systems combining microfluidic and microoptical elements for fluorescence detection

This paper presents the fabrication of a microchemical chip for the detection of fluorescence species in microfluidics. The microfluidic network is wet-etched in a Borofloat 33 (Pyrex) glass wafer and sealed by means of a second wafer. Unlike other similar chemical systems, the detection system is realized with the help of microfabrication techniques and directly deposited on both sides of the microchemical chip. The detection system is composed of the combination of refractive microlens arrays and chromium aperture arrays. The microfluidic channels are 60 /spl mu/m wide and 25 /spl mu/m deep. The utilization of elliptical microlens arrays to reduce aberration effects and the integration of an intermediate (between the two bonded wafers) aluminum aperture array are also presented. The elliptical microlenses have a major axis of 400 /spl mu/m and a minor axis of 350 /spl mu/m. The circular microlens diameters range from 280 to 300 /spl mu/m. The apertures deposited on the outer chip surfaces are etched in a 3000-/spl Aring/-thick chromium layer, whereas the intermediate aperture layer is etched in a 1000-/spl Aring/-thick aluminum layer. The overall thickness of this microchemical system is less than 1.6 mm. The wet-etching process and new bonding procedures are discussed. Moreover, we present the successful detection of a 10-nM Cy5 solution with a signal-to-noise ratio (SNR) of 21 dB by means of this system.

[1]  Ronald D. Goodman,et al.  Coatings on glass , 1984 .

[2]  G. A. C. M. Spierings,et al.  The dissolution of Na2O-MgO-CaO-SiO2 glass in aqueous HF solutions , 1987 .

[3]  A. Manz,et al.  Miniaturized total chemical analysis systems: A novel concept for chemical sensing , 1990 .

[4]  A. Manz,et al.  A silicon flow cell for optical detection in miniaturized total chemical analysis systems , 1992 .

[5]  M. Nese,et al.  Anodic bonding of silicon to silicon wafers coated with aluminium, silicon oxide, polysilicon or silicon nitride , 1993 .

[6]  D. J. Harrison,et al.  Micromachining of capillary electrophoresis injectors and separators on glass chips and evaluation of flow at capillary intersections , 1994 .

[7]  Daniel Malacara,et al.  Handbook of lens design , 1994 .

[8]  N. F. de Rooij,et al.  Line-Addressable Torsional Micromirrors for Light Modulator Arrays , 1994 .

[9]  Johannes Schwider,et al.  Twyman-Green interferometer for testing microspheres , 1995 .

[10]  D. J. Harrison,et al.  Microfabrication of a Planar Absorbance and Fluorescence Cell for Integrated Capillary Electrophoresis Devices , 1996 .

[11]  H. Herzig Micro-Optics : Elements, Systems And Applications , 1997 .

[12]  A. Woolley,et al.  High-speed DNA genotyping using microfabricated capillary array electrophoresis chips. , 1997, Analytical chemistry.

[13]  P. Nussbaum,et al.  Design, fabrication and testing of microlens arrays for sensors and microsystems , 1997 .

[14]  Andreas Manz,et al.  Holographic refractive index detector for application in microchip-based separation systems , 1998 .

[15]  G. Kovacs Micromachined Transducers Sourcebook , 1998 .

[16]  S. Jacobson,et al.  Counting single chromophore molecules for ultrasensitive analysis and separations on microchip devices. , 1998, Analytical chemistry.

[17]  Gregor Ocvirk,et al.  Optimization of confocal epifluorescence microscopy for microchip-based miniaturized total analysis systems , 1998 .

[18]  WU MINGC. Micromachining for Optical and Optoelectronic Systems , 1998 .

[20]  Johan Roeraade,et al.  Method for fabrication of microfluidic systems in glass , 1998 .

[21]  R. Mathies,et al.  Single-molecule detection of DNA separations in microfabricated capillary electrophoresis chips employing focused molecular streams. , 1999, Analytical chemistry.

[22]  R A Mathies,et al.  Capillary array electrophoresis DNA sequencing. , 1999, Analytical chemistry.

[23]  Micro-optic integration for fluorescence detection in µTAS systems , 1999 .

[24]  J. Rossier,et al.  Electrochemical detection in polymer microchannels. , 1999, Analytical chemistry.

[25]  Thomas Martin,et al.  Miniaturized piezoelectrically driven fiber optic switches with transmittive micro-optics , 1999, Photonics West - Micro and Nano Fabricated Electromechanical and Optical Components.

[26]  C. Henry,et al.  Dual-electrode electrochemical detection for poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips. , 2000, Analytical chemistry.

[27]  Swinney,et al.  Chip-scale universal detection based on backscatter interferometry , 2000, Analytical chemistry.

[28]  D. J. Harrison,et al.  Red diode laser induced fluorescence detection with a confocal microscope on a microchip for capillary electrophoresis. , 2000, Biosensors & bioelectronics.

[29]  D. J. Harrison,et al.  A multireflection cell for enhanced absorbance detection in microchip‐based capillary electrophoresis devices , 2000, Electrophoresis.

[30]  N. F. de Rooij,et al.  Valveless, sealed microfluidic device for automated heterogeneous immunoassay: design and operational considerations , 2000 .

[31]  M. Vellekoop,et al.  Glass-to-glass anodic bonding with standard IC technology thin films as intermediate layers , 2000 .

[32]  Hans Peter Herzig,et al.  Holographically recorded gratings on microlenses for a miniaturized spectrometer array , 2000 .

[33]  Hans Peter Herzig,et al.  Microlens systems for fluorescence detection in chemical microsystems , 2001 .

[34]  Editorial: Electrophoresis 10/2002 , 2002 .