Coordinated design of under-excitation limiters and power system stabilizers

Summary form only given as follows. The inherent dynamical relationship between the under-excitation limiter (UEL) and the power system stabilizer (PSS) control loops in synchronous generators is studied using the frequency response technique. While the stabilizers are effective in introducing electromechanical damping torque components into the generators, it is shown that the limiters should be designed to effect a much slower response characteristics as their main function is to prevent excessive stator end-core heating. The analysis also shows that a reduction in the values of the slope of the boundary curves, which prescribe the operating region of the limiters, is accompanied by a decrease in the damping level of the closed-loop excitation control systems. A method which decouples the design procedure of the UEL from that of the PSS is then proposed.

[1]  E. Handschin,et al.  A new method of excitation control based on fuzzy set theory , 1993 .

[2]  S. S. Choi,et al.  Effects of underexcitation limiters on operation of remote generating station , 1991 .

[3]  Charles Concordia,et al.  Concepts of Synchronous Machine Stability as Affected by Excitation Control , 1969 .

[4]  S. S. Choi,et al.  A technique for tuning under excitation limiters , 1999 .

[5]  A.J.P. Ramos,et al.  Performance of under excitation limiter of synchronous machines for system critical disturbances , 1997 .

[6]  R. C. Schaefer,et al.  Minimum/maximum excitation limiter performance goals for small generation , 1995 .

[7]  E. Larsen,et al.  IEEE Transactions on Power Apparatus and Systems, Vol. PAS-100, No. 6 June 1981 APPLYING POWER SYSTEM STABILIZERS PART I: GENERAL CONCEPTS , 2006 .

[8]  S. S. Choi,et al.  Under-excitation limiter design by variable structure control , 1996 .

[9]  R. Larkin,et al.  Steady state stability of a remote gas-turbine generating station: field tests and validation of computer simulation results , 1993 .

[10]  S.E.M. de Oliveira,et al.  Impact of under-excitation limit control on power system dynamic performance , 1995 .

[11]  J.R. Ribeiro Minimum Excitation Limiter Effects on Generator Response to System Disturbances , 1991, IEEE Power Engineering Review.

[12]  S. Choi,et al.  Under excitation limiter and its role in preventing excessive synchronous generator stator end-core heating , 2000 .

[13]  M. Temoshok,et al.  Underexcited Reactive Ampere Limit for Modern Amplidyne Voltage Regulator [includes discussion] , 1954, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.