Highly-sensitive silicon-on-insulator sensor based on two cascaded micro-ring resonators with vernier effect

Abstract A highly-sensitive integrated optical biosensor based on two cascaded micro-rings resonator (MRR) is investigated theoretically and experimentally. The free spectral ranges (FSRs) of two cascaded micro-rings are designed to be slightly different in order to generate Vernier effect. A preliminary investigation of our sensor with a Q factor of 2 × 10 4 using different ethanol concentrations shows that the Vernier effect can improve the sensitivity to 1300 nm per refractive index unit (RIU), compared to 62 nm/RIU for a single ring sensor. The sensor also has a large measurement range of refractive index change up to 1.15 × 10 − 2 RIU. It can be useful for low-cost and highly-sensitive optical biosensor system.

[1]  Otto Schwelb,et al.  Vernier operation of series‐coupled optical microring resonator filters , 2003 .

[2]  M. Dagenais,et al.  Monolayer Detection of Biochemical Agents Using Etched-Core Fiber Bragg Grating Sensors , 2007, IEEE Photonics Technology Letters.

[3]  R. Baets,et al.  Silicon-on-Insulator microring resonator for sensitive and label-free biosensing. , 2007, Optics express.

[4]  Zheng Zheng,et al.  Dynamically modulated intensity interrogation scheme using waveguide coupled surface plasmon resonance sensors , 2010 .

[5]  B. Lamontagne,et al.  A Silicon-on-Insulator Photonic Wire Based Evanescent Field Sensor , 2006, IEEE Photonics Technology Letters.

[6]  S. Kawata,et al.  Optical chemical sensor based on surface plasmon measurement. , 1988, Applied optics.

[7]  Jian-Jun He,et al.  Highly-sensitive optical sensor using two cascaded-microring resonators with Vernier effect , 2009, 2009 Asia Communications and Photonics conference and Exhibition (ACP).

[8]  Jian-Jun He,et al.  Wavelength switchable semiconductor laser using half-wave V-coupled cavities. , 2008, Optics express.

[9]  B. Liedberg,et al.  Principles of biosensing with an extended coupling matrix and surface plasmon resonance , 1993 .

[10]  David R. Lide,et al.  CRC handbook of chemistry and physics on CD-ROM , 2000 .

[11]  L.A. Coldren,et al.  Monolithic tunable diode lasers , 2000, IEEE Journal of Selected Topics in Quantum Electronics.

[12]  B. Lamontagne,et al.  Spiral-path high-sensitivity silicon photonic wire molecular sensor with temperature-independent response. , 2008, Optics letters.

[13]  Jian H. Zhao,et al.  Optical Filter Design and Analysis , 1999 .

[14]  B. D. Gupta,et al.  Fiber-Optic Sensors Based on Surface Plasmon Resonance: A Comprehensive Review , 2007, IEEE Sensors Journal.

[15]  W. Ehrfeld,et al.  Fabrication of a planar grating spectrograph by deep-etch lithography with synchrotron radiation , 1991 .

[16]  P Waldron,et al.  A high-resolution silicon-on-insulator arrayed waveguide grating microspectrometer with sub-micrometer aperture waveguides. , 2007, Optics express.

[17]  A. Mitchell,et al.  Width Dependence of Inherent TM-Mode Lateral Leakage Loss in Silicon-On-Insulator Ridge Waveguides , 2007, IEEE Photonics Technology Letters.