Performance simulation of climate adaptive building shells - Smart Energy Glass as a case study

As opposed to traditional building shells, climate adaptive building shells (CABS) do have the ability to change their properties and behavior over time. Provided they are designed and operated effectively, CABS offer the potential for energy savings without the need for compromising comfort levels. This paper explores the role that building performance simulation (BPS) can play in designing CABS. After analyzing the distinguishing characteristics of CABS, the need for BPS is introduced. The potential role of BPS is then illustrated via the case study of Smart Energy Glass. Based on a description of underlying physics, the model abstraction process is discussed first. This results in an integrated model for performance simulations that couples TRNSYS and DAYSIM. This model is empirically validated and subsequently used to evaluate the potential of Smart Energy Glass in a renovation case under various operational scenario’s. The paper concludes with some suggestions for future research and development of Smart Energy Glass.

[1]  Christoph F. Reinhart,et al.  Lightswitch-2002: a model for manual and automated control of electric lighting and blinds , 2004 .

[2]  David K. Benson,et al.  Design goals and challenges for a photovoltaic-powered electrochromic window covering , 1995 .

[3]  A. Meyer,et al.  Luminescent Solar Concentrators--a review of recent results. , 2008, Optics express.

[4]  Michael-Marcus Vogt,et al.  move--architecture-in-motion---dynamic-components-and-elements , 2010 .

[5]  Per Heiselberg State of the art of Annex 44 "Integrating Environmentally Responsive Elements in Buildings" , 2007 .

[6]  J. Harnisch,et al.  Mitigation of CO2 emissions from the EU-15 building stock. Beyond the EU directive on the energy performance of buildings , 2006, Environmental science and pollution research international.

[7]  A. Goetzberger,et al.  Solar energy conversion with fluorescent collectors , 1977 .

[8]  Axel Ritter,et al.  Smart Materials in Architecture, Interior Architecture and Design , 2006 .

[9]  André Kostro,et al.  Principles of Monte-Carlo ray-tracing simulations of quantum dot solar concentrators , 2007 .

[10]  Jules Moloney,et al.  A Framework for the Design of Kinetic Façades , 2007 .

[11]  Thomas Boermans,et al.  Mitigation of CO2 Emissions from the EU-15 Building Stock. Beyond the EU Directive on the Energy Performance of Buildings (9 pp) , 2006 .

[12]  J. Wienold DYNAMIC DAYLIGHT GLARE EVALUATION , 2009 .

[13]  R. Loonen Climate adaptive building shells:what can we simulate? , 2010 .

[14]  Laura Bellia,et al.  Daylight glare: a review of discomfort indexes , 2008 .

[15]  John Mardaljevic,et al.  Electrochromic glazing and facade photovoltaic panels: a strategic assessment of the potential energy benefits , 2008 .

[16]  Jan Christoph Goldschmidt,et al.  Novel Solar Cell Concepts , 2009 .

[17]  Refrigerating ASHRAE handbook of fundamentals : an instrument of service prepared for the profession containing reference material pertaining to fundamental theory and basic data ... , 1972 .

[18]  Jon Hand,et al.  CONTRASTING THE CAPABILITIES OF BUILDING ENERGY PERFORMANCE SIMULATION PROGRAMS , 2008 .

[19]  Stephen Sharples,et al.  Environment, Technology and Sustainability , 2009 .

[20]  Thorsten Klooster,et al.  Smart Surfaces - and their Application in Architecture and Design , 2009 .

[21]  Andreas Jonsson,et al.  Evaluation of control strategies for different smart window combinations using computer simulations , 2010 .

[22]  Nicholas J. Ekins-Daukes,et al.  A new approach to modelling quantum dot concentrators , 2003 .

[23]  Aslihan Tavil,et al.  Energy and visual comfort performance of electrochromic windows with overhangs , 2007 .

[24]  J. Timmer,et al.  Dynamic annual daylight simulations based on one-hour and one-minute means of irradiance data , 2002 .

[25]  Antonio Piccolo,et al.  Thermal performance of an electrochromic smart window tested in an environmental test cell , 2010 .