Scattering Parameters-Based Channel Characterization and Modeling for Underground Medium-Voltage Power-Line Communications

Power-line communications (PLC) technologies rely on the power grid for data transmission. Since the communications channel is already deployed, this communication alternative is specially interesting for the power grid owner (i.e., the electrical utility). The medium-voltage (MV) distribution network, located after the last step-down electrical substation with typical levels from 6 to 25 kV, directly feeds large consumers and small ones through several transform stations. The growing interest on MV-PLC technology, the natural aggregation point for data coming and going into the low-voltage (LV) network, faces the same issue that the LV-PLC technology did (and does): standardization. In this way, a properly implemented channel model will allow the design of suitable modulation and access methods. This paper proposes a deterministic channel model for the MV underground network transfer function, based on a complete set of measurements performed in an MV urban ring. Moreover, the characterization of the MV-PLC channel elements as well as the noise scenario and access impedance have been carried out.

[1]  Chen Jian,et al.  Channel Model and Measurement Methods for 10-kV Medium-Voltage Power Lines , 2007, IEEE Transactions on Power Delivery.

[2]  H. Edin,et al.  Extraction of high frequency power cable characteristics from S-parameter measurements , 2004, IEEE Transactions on Dielectrics and Electrical Insulation.

[3]  Bjorn Gustavsen Wide band modeling of power transformers , 2004 .

[4]  Klaus Dostert,et al.  A multipath model for the powerline channel , 2002, IEEE Trans. Commun..

[5]  M.B. Pursley,et al.  Crosscorrelation properties of pseudorandom and related sequences , 1980, Proceedings of the IEEE.

[6]  Chen Jian,et al.  Research of Noise Characteristics for 10-kV Medium-Voltage Power Lines , 2007, IEEE Transactions on Power Delivery.

[7]  F. Segal,et al.  A CHARACTERIZATION OF FIBRANT SEGAL CATEGORIES , 2006, math/0603400.

[8]  K. Dostert,et al.  Analysis and modeling of impulsive noise in broad-band powerline communications , 2002 .

[9]  Roland Eriksson,et al.  Calibration for time domain propagation constant measurements on power cables , 2002, Conference Digest Conference on Precision Electromagnetic Measurements.

[10]  Duan Jiandong,et al.  Research of Impedance Characteristics for Medium-Voltage Power Networks , 2007, IEEE Transactions on Power Delivery.

[11]  T. Tran-Quoc,et al.  High frequency power transformer modeling for Power Line Communication applications , 2006, 2006 IEEE PES Power Systems Conference and Exposition.