Noninvasive vascular ultrasound elastography applied to the characterization of experimental aneurysms and follow-up after endovascular repair

Experimental and simulation studies were conducted to noninvasively characterize abdominal aneurysms with ultrasound (US) elastography before and after endovascular treatment. Twenty three dogs having bilateral aneurysms surgically created on iliac arteries with venous patches were investigated. In a first set of experiments, the feasibility of elastography to differentiate vascular wall elastic properties between the aneurismal neck (healthy region) and the venous patch (pathological region) was evaluated on six dogs. Lower strain values were found in venous patches (p < 0.001). In a second set of experiments, 17 dogs having endovascular repair (EVAR) by stent graft (SG) insertion were examined three months after SG implantation. Angiography, color Doppler US, examination of macroscopic sections and US elastography were used. The value of elastography was validated with the following end points by considering a solid thrombus of a healed aneurysm as a structure with small deformations and a soft thrombus associated with endoleaks as a more deformable tissue: (1) the correlation between the size of healed organized thrombi estimated by elastography and by macroscopic examinations; (2) the correlation between the strain amplitude measured within vessel wall elastograms and the leak size; and (3) agreement on the presence and size of endoleaks as determined by elastography and by combined reference imaging modalities (angiography + Doppler US). Mean surfaces of solid thrombi estimated with elastography were found correlated with those measured on macroscopic sections (r = 0.88, p < 0.001). Quantitative strain values measured within the vessel wall were poorly linked with the leak size (r = 0.12, p = 0.5). However, the qualitative evaluation of leak size in the aneurismal sac was very good, with a Kappa agreement coefficient of 0.79 between elastography and combined reference imaging modalities. In summary, complementing B-scan and color Doppler, noninvasive US elastography was found to be potentially a relevant tool for aneurismal follow-up after EVAR, provided it allows geometrical and mechanical characterizations of the solid thrombus within the aneurismal sac. This elasticity imaging technique might help detecting potential complications during follows-up subsequent to EVAR.

[1]  R. Fairman,et al.  Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms. , 2001, Journal of vascular surgery.

[2]  R N Vaishnav,et al.  Static Linear and Nonlinear Elastic Properties of Normal and Arterialized Venous Tissue in Dog and Man , 1975, Circulation research.

[3]  Gregg Trahey,et al.  Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility. , 2002, Ultrasound in medicine & biology.

[4]  K J Parker,et al.  Tissue response to mechanical vibrations for "sonoelasticity imaging". , 1990, Ultrasound in medicine & biology.

[5]  S. Raptis,et al.  Endovascular treatment of abdominal aortic aneurysm , 2004, The British journal of surgery.

[6]  Rodney A. White,et al.  Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. , 2002, Journal of vascular surgery.

[7]  P. Serruys,et al.  Characterizing Vulnerable Plaque Features With Intravascular Elastography , 2003, Circulation.

[8]  Michel Bertrand,et al.  Lagrangian speckle model and tissue-motion estimation-theory [ultrasonography] , 1999, IEEE Transactions on Medical Imaging.

[9]  J. Sim,et al.  The kappa statistic in reliability studies: use, interpretation, and sample size requirements. , 2005, Physical therapy.

[10]  G. Moneta,et al.  Comparison of Endovascular Aneurysm Repair With Open Repair in Patients With Abdominal Aortic Aneurysm (EVAR Trial 1), 30-Day Operative Mortality Results: Randomised Controlled Trial , 2006 .

[11]  M. Fink,et al.  Time-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging , 1999, Ultrasonic imaging.

[12]  Erik Buskens,et al.  A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms. , 2004, The New England journal of medicine.

[13]  Elasticity and compliance of canine femoral and jugular vein segments. , 1977, The American journal of physiology.

[14]  J. Lasheras The Biomechanics of Arterial Aneurysms , 2007 .

[15]  S. L. Murphy,et al.  Deaths: final data for 2003. , 2006, National vital statistics reports : from the Centers for Disease Control and Prevention, National Center for Health Statistics, National Vital Statistics System.

[16]  A. AbuRahma,et al.  Computed Tomography versus Color Duplex Ultrasound for Surveillance of Abdominal Aortic Stent-Grafts , 2005, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[17]  I. Loftus,et al.  Quality control during endovascular aneurysm repair: monitoring aneurysmal sac pressure and superficial femoral artery flow velocity. , 1999 .

[18]  P. Hoskins,et al.  The relationship between abdominal aortic aneurysm distensibility and serum markers of elastin and collagen metabolism. , 2001, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[19]  P. Faries,et al.  Evaluation of the accuracy of a wireless pressure sensor in a canine model of retrograde-collateral (type II) endoleak and correlation with histologic analysis. , 2006, Journal of vascular surgery.

[20]  H. Ermert,et al.  A time-efficient and accurate strain estimation concept for ultrasonic elastography using iterative phase zero estimation , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  Zhonghua Sun Diagnostic value of color duplex ultrasonography in the follow-up of endovascular repair of abdominal aortic aneurysm. , 2006, Journal of vascular and interventional radiology : JVIR.

[22]  C. D. de Korte,et al.  Intravascular ultrasound elastography in human arteries: initial experience in vitro. , 1998, Ultrasound in medicine & biology.

[23]  G Finet,et al.  Axial strain imaging of intravascular data: results on polyvinyl alcohol cryogel phantoms and carotid artery. , 2001, Ultrasound in medicine & biology.

[24]  EVAR trial participants,et al.  Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial , 2005, The Lancet.

[25]  L. Gaboury,et al.  Endovascular aortic aneurysm repair with stent-grafts: experimental models can reproduce endoleaks. , 2004, Journal of vascular and interventional radiology : JVIR.

[26]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[27]  G. Soulez,et al.  Type I and collateral flow in experimental aneurysm models treated with stent-grafts. , 2007, Journal of vascular and interventional radiology : JVIR.

[28]  G. Soulez,et al.  Noninvasive vascular elastography: toward a complementary characterization tool of atherosclerosis in carotid arteries. , 2007, Ultrasound in medicine & biology.

[29]  J. Ophir,et al.  Reduction of Image Noise in Elastography , 1993 .

[30]  C. McCollum,et al.  Midterm follow-up of a single-center experience of endovascular repair of abdominal aortic aneurysms with use of the Talent stent-graft. , 2006, Journal of vascular and interventional radiology : JVIR.

[31]  S. Thomas,et al.  Results from the prospective registry of endovascular treatment of abdominal aortic aneurysms (RETA): mid term results to five years. , 2005, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[32]  R. Uflacker,et al.  Endovascular treatment of abdominal aortic aneurysms: a review , 2001, European Radiology.

[33]  A Giudiceandrea,et al.  The Mechanical Behavior of Vascular Grafts: A Review , 2001, Journal of biomaterials applications.

[34]  J. Hamming,et al.  Aneurysm sac pressure monitoring: does the direction of pressure measurement matter in fibrinous thrombus? , 2007, Journal of vascular surgery.

[35]  Arialdi M. Miniño,et al.  Deaths: final data for 2008, United States , 2006 .

[36]  J. Ophir,et al.  Elastography: Elasticity Imaging Using Ultrasound with Application to Muscle and Breast in Vivo , 1993, Ultrasonic imaging.

[37]  L. Reilly,et al.  Long-term outcome and reintervention after endovascular abdominal aortic aneurysm repair using the Zenith stent graft. , 2007, Journal of vascular surgery.

[38]  Elisabeth Brusseau,et al.  On the potential of the Lagrangian speckle model estimator to characterize atherosclerotic plaques in endovascular elastography: in vitro experiments using an excised human carotid artery. , 2005, Ultrasound in medicine & biology.

[39]  J. H. van Bockel,et al.  Pulsatile wall motion and blood pressure in aneurysms with open and thrombosed endoleaks--comparison of a wall track system and M-mode ultrasound scanning: an in vitro and animal study. , 2000, Journal of vascular surgery.

[40]  Richard G P Lopata,et al.  Noninvasive two-dimensional strain imaging of arteries: validation in phantoms and preliminary experience in carotid arteries in vivo. , 2007, Ultrasound in medicine & biology.

[41]  J. Heckenkamp,et al.  Intra-aneurysm sac pressure--the holy grail of endoluminal grafting of AAA. , 2002, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[42]  J. Hamming,et al.  Aneurysm Sac Pressure Monitoring: Effect of Pulsatile Motion of the Pressure Sensor on the Interpretation of Measurements , 2006, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[43]  Jacques Ohayon,et al.  Non-invasive high-frequency vascular ultrasound elastography , 2005, Physics in medicine and biology.

[44]  Krassi Ivancev,et al.  Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair. , 2003, Journal of vascular surgery.

[45]  J. Raymond,et al.  Role of the Endothelial Lining in Persistence of Residual Lesions and Growth of Recurrences After Endovascular Treatment of Experimental Aneurysms , 2002, Stroke.